Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
XPSUVN31AP – safety module, Harmony XPS, zero speed monitoring with time delay, 48 to 240V AC or DC, screw
XPSUVN31AP
safety module, Harmony XPS, zero speed monitoring with time delay, 48 to 240V AC or DC, screw

This safety relay is designed for zero speed monitoring with delayed access to dangerous area. The safety relay is powered with 48 to 240V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 3 safety inputs, 1 NO output configurable between 0,5s and 60s, and 2solid state diagnostic outputq with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 3 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061 and SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, TÜV. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Country of Origin Indonesia
Width 22.5 mm
Height 100 mm
Weight 0.2 kg
Product Certifications
  • TÜV
  • cULus
[Us] Rated Supply Voltage 48...240 V AC/DC - 10...10 %
Range Of Product Harmony Safety Automation
Product Or Component Type safety module
Safety Module Name XPSUVN
Number Of Additional Circuits 2 solid state outputs
Output Type relay, 1 NO, volt-free
Safety Module Application for zero speed detection
Safety Reliability Data
  • MTTFd > 30 years ISO 13849-1
  • Dcavg = 98.9 % ISO 13849-1
  • PFHd = 2.44E-9 1/h ISO 13849-1
  • HFT = 1 IEC 62061
  • PFHd = 2.44E-9 1/h IEC 62061
  • SFF > 99% IEC 62061
  • HFT = 1 IEC 61508-1
  • PFHd = 2.44E-9 1/h IEC 61508-1
  • SFF > 99% IEC 61508-1
  • type = B IEC 61508-1
Function Of Module
  • monitoring 3-phase motor
  • monitoring 3-phase motor with star-delta starting
  • monitoring 3-phase motor with variable number of poles
  • monitoring 3-phase motor with variable number of poles and star-delta starting
  • monitoring dc motor
  • monitoring servo motor
  • monitoring 3-phase motor supplied by variable speed drive
  • monitoring 3-phase motor supplied by servo drive
  • controlling enegization to open of guard switch type XCSE, XCSLE, XCSLF, XCST
Safety Level
  • can reach PL e/category 3 for normally open relay contact ISO 13849-1
  • can reach SILCL 3 for normally open relay contact IEC 62061
  • can reach SIL 3 for normally open relay contact IEC 61508
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1811003EN
Sustainable Offer Status Green Premium product
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI1811003EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Ambient Air Temperature For Operation -25-55 °C
Ip Degree Of Protection
  • IP20 terminals)IEC 60529
  • IP40 housing)IEC 60529
  • IP54 mounting area)IEC 60529
Ambient Air Temperature For Storage -40-70 °C
Relative Humidity 5-95 % non-condensing
Height 100 mm
[Ith] Conventional Free Air Thermal Current 6 A NO relay output circuit
Mounting Support 35 mm symmetrical DIN rail
Power Consumption In W 2.5 W
Minimum Output Voltage 5 V relay output
Minimum Output Current 10 mA relay output
Time Delay
  • 0.5 s
  • 1 s
  • 2 s
  • 3 s
  • 5 s
  • 8 s
  • 12 s
  • 20 s
  • 35 s
  • 60 s
Associated Fuse Rating 6 A gG relay output IEC 60947-1
Local Signalling
  • LED green power power ON
  • LED red error error
  • LED yellow state status
  • LED yellow L12 input line comparison
  • LED yellow L32 input line comparison
[Uimp] Rated Impulse Withstand Voltage 4 kV II IEC 60947-1
Net Weight 0.2 kg
Standards
  • IEC 60947-5-1
  • IEC 61508-1 functional safety standard
  • IEC 61508-2 functional safety standard
  • IEC 61508-3 functional safety standard
  • IEC 61508-4 functional safety standard
  • IEC 61508-5 functional safety standard
  • IEC 61508-6 functional safety standard
  • IEC 61508-7 functional safety standard
  • ISO 13849-1 functional safety standard
  • IEC 62061 functional safety standard
[Ui] Rated Insulation Voltage
  • 690 V phase to phase 2)IEC 60947-1
  • 400 V phase to earth 2)IEC 60947-1
[Ie] Rated Operational Current
  • 5 A AC-1 for normally open relay contact
  • 3 A AC-15 for normally open relay contact
  • 5 A DC-1 for normally open relay contact
  • 3 A DC-13 for normally open relay contact
Power Consumption In Va 5.5 VA
Input Voltage 690 V
Connections - Terminals
  • removable screw terminal block solid or flexible 0.2...2.5 mm²
  • removable screw terminal block flexible with ferrule 0.25...2.5 mm² single conductor
  • removable screw terminal block solid or flexible 0.2...1.5 mm² twin conductor
  • removable screw terminal block flexible with ferrule 2 x 0.25...1 mm² without cable end, with bezel
  • removable screw terminal block flexible with ferrule 2 x 0.5...1.5 mm² with cable end, with bezel
Width 22.5 mm
Depth 120 mm
Input Detection Threshold
  • 50 mV
  • 65 mV
  • 85 mV
  • 110 mV
  • 140 mV
  • 180 mV
  • 230 mV
  • 300 mV
  • 400 mV
  • 500 mV
Documents