Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
XALK178W3B140G – Control station, Harmony XALD, XALK, plastic, yellow lid, 1 Estop push button 40mm, turn to release, illum ring white red fixed, 1NO 2NC, 24V AC DC
XALK178W3B140G
Control station, Harmony XALD, XALK, plastic, yellow lid, 1 Estop push button 40mm, turn to release, illum ring white red fixed, 1NO 2NC, 24V AC DC

This control station with mushroom head push-button for emergency stop function is ideal for situations where quick actions are required for a process or machine to function correctly or where operator movements require maximum ergonomy. Its schematic is clearly distinguishable thanks to clear colors. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP65, making it ideal for operation in harsh environments.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Certifications
  • UL Listed
  • CSA
Ik Degree Of Protection IK05 conforming to IEC 62262
Ambient Air Temperature For Operation -40-70 °C
Standards
  • CSA C22.2 No 14
  • IEC 60947-5-1
  • IEC 60947-5-4
  • UL 508
  • IEC 60947-1
  • JIS C 4520
Shock Resistance
  • 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27
  • 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
  • 25 gn 6 ms) 1000 shocks on each axis IEC 60068-2-27
Vibration Resistance
  • 5 gn 10-500 Hz)IEC 60068-2-6
  • 25 mm peak to peak 2-10 Hz)IEC 60068-2-6
Ip Degree Of Protection
  • IP66 IEC 60529
  • IP67 IEC 60529
  • IP69 IEC 60529
  • IP69K ISO 20653
  • Type 13 UL 50E
  • Type 12 UL 50E
  • Type 4 UL 50E
  • Type 4X UL 50E
Ambient Air Temperature For Storage -40-70 °C
Protective Treatment TH
Warranty 18 months
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1806010EN
Sustainable Offer Status Green Premium product
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI1806010EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Operating Force 44 N
Short-Circuit Protection 10 A cartridge fuse gG IEC 60947-5-1
Operating Travel
  • 1.5 mm NC changing electrical state)
  • 4.3 mm total travel)
Contacts Material silver alloy (Ag/Ni)
Positive Opening with IEC 60947-5-1 appendix K
[Ith] Conventional Free Air Thermal Current 10 A IEC 60947-5-1
Cable Entry
  • 1 knock-out for cable entry 0-14 mm
  • 2 knock-outs for Pg 13 cable gland and ISO M20 0-12 mm
Net Weight 0.180 kg
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947-1
Electrical Insulation Class class II IEC 61140
Resistance To High Pressure Washer 7000000 Pa 55 °C 0.1 m
Electrical Durability
  • 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
  • 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
  • 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
  • 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
  • 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
Connections - Terminals
  • screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1
  • screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
[Ui] Rated Insulation Voltage 600 V 3)IEC 60947-1
[Ie] Rated Operational Current
  • 3 A 240 V, AC-15, A600 IEC 60947-5-1
  • 6 A 120 V, AC-15, A600 IEC 60947-5-1
  • 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1
  • 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1
  • 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1
  • 1.2 A 600 V, AC-15, A600 IEC 60947-5-1
Resistance To Electrostatic Discharge
  • 4 kV on contact (on metal parts) IEC 61000-4-2
  • 8 kV in free air (in insulating parts)
Mechanical Durability 300000 cycles
Electrical Reliability
  • λ < 10exp(-6) 5 V, 1 mA IEC 60947-5-4
  • λ < 10exp(-8) 17 V, 5 mA IEC 60947-5-4
Tightening Torque 0.8-1.2 N.m IEC 60947-1
Shape Of Screw Head
  • cross Philips no 1
  • cross pozidriv No 1
  • slotted flat Ø 4 mm
  • slotted flat Ø 5.5 mm
Country of Origin Czechia
Weight 0.180 kg
[Us] Rated Supply Voltage 24 V AC/DC
Control Station Application
  • emergency switching off function
  • emergency stop function
Product Destination for XB5 Ø 22 mm control and signalling units
Reset turn to release
Range Of Product Harmony XALK
Colour Of Base Of Enclosure light grey RAL 7035)
Control Station Composition 1 mushroom head Ø 40 mm push-button, red 1 NO + 2 NC
Operators Description red unmarked 1 NO + 2 NC
Product Or Component Type complete control station
Material polycarbonate
Operator Profile 1 mushroom head push-button
Colour Of Cover yellow RAL 1021)
Contact Operation slow-break
Device Short Name XALK
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews