Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
VW3A7105 – braking unit, Altivar, 100kW, 400/480V, for variable speed drive
VW3A7105
braking unit, Altivar, 100kW, 400/480V, for variable speed drive

This braking unit is an option for variable speed drives of Altivar range. The minimum resistor value to associate is 2.5Ohm. This braking unit allows Altivar 71 drives to operate while braking to a standstill or during “generator” operation, by dissipating the energy in the braking resistor. Its protection index is IP20. Thermal protection is provided by an integrated temperature probe. It weighs 28kg.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Country of Origin China
Width 216 mm
Height 658 mm
Weight 17 kg
Thermal Losses 400 W
Minimum Resistor Value To Associate 2.5 Ohm
Product Compatibility
  • variable speed drive ATV930 without braking chopper 110 kW 380...480 V
  • variable speed drive ATV930 without braking chopper 130 kW 380...480 V
  • variable speed drive ATV930 without braking chopper 160 kW 380...480 V
Range Compatibility Altivar Process ATV900
Protection Type integrated thermal protection thermal probe
Rohs Exemption Information Yes
Mercury Free Yes
Toxic Heavy Metal Free Yes
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
China Rohs Regulation X
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Ambient Air Temperature For Operation -10-50 °C
Ip Degree Of Protection
  • IP20
  • IP21 on top)
Ambient Air Temperature For Storage -40-70 °C
Operating Altitude
  • <= 3280.84 ft (1000 m) without derating
  • 3280.84...13123.36 ft (1000...4000 m) with current derating 1 % per 100 m
Mechanical Robustness vibrations class 3M4 IEC 60721-3-3
Height 658 mm
Volume Of Cooling Air 166 m3/h
Permanent Braking Power 100 kW at constant power and at engage threshold)
Net Weight 17 kg
Maximum Dc Bus Voltage 850 V
Maximum Braking Power 160 kW
Load Factor
  • 0.05 320 kW at constant power and at engage threshold
  • 0.15 250 kW at constant power and at engage threshold
  • 0.5 200 kW at constant power and at engage threshold
  • 1 160 kW at constant power and at engage threshold
Operating Position vertical +/- 10 degree
Activation Threshold 780 V DC +/- 1 %
Width 216 mm
Depth 303 mm
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews