RE22R1DMR – dual function relay, Harmony Timer Relays, 8A, 1CO, 0.05s…300h, symmetrical flashing, 24…240V AC DC
RE22R1DMR
dual function relay, Harmony Timer Relays, 8A, 1CO, 0.05s…300h, symmetrical flashing, 24...240V AC DC

This Harmony RE22 modular dual function timer can be set between 1 seconds and 300 hours, has an output rating of 8 amperes and it is 22.5 millimeters wide. This modular dual function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. Dual function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Country of Origin Indonesia
Width 22.5 mm
Weight 0.1 kg
Discrete Output Type relay
Range Of Product Harmony Timer Relays
Product Or Component Type modular timing relay
Nominal Output Current 8 A
Device Short Name RE22
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1401008EN
Sustainable Offer Status Green Premium product
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation X
Circularity Profile ENVEOLI1401008EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Number Of Functions 2
Power Consumption In W 1.5 W 240 V DC
Safety Reliability Data
  • B10d = 280000
  • MTTFd = 308.2 years
Contacts Type And Composition 1 C/O timed contact, cadmium free
Setting Accuracy Of Time Delay +/- 10 % of full scale 25 °C IEC 61812-1
Creepage Distance 4 kV/3 IEC 60664-1
Maximum Delay Response 100 ms
Insulation Resistance 100 MOhm 500 V DC IEC 60664-1
Immunity To Microbreaks 10 ms
Power Consumption In Va 3-3 VA 240 V AC
Switching Capacity In Va 2000 VA
Minimum Pulse Duration
  • 100 ms with load in parallel
  • 30 ms
Maximum Switching Current 8 A
Function Available
  • D- Symmetrical flashing relay (starting pulse-off)-1 C/O
  • Dw- Symmetrical flashing relay (starting pulse-off) w/ retrigger/restart-1 C/O
Voltage Range 0.85...1.1 Us
Net Weight 0.1 kg
Mounting Position any position
Control Type with test button
Voltage Drift +/- 0.2 %/V
Reset Time 120 ms on de-energisation
Maximum Switching Voltage 250 V AC
Connections - Terminals
  • screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
  • screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
  • screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
[Us] Rated Supply Voltage 24...240 V AC/DC 50/60 Hz
Temperature Drift +/- 0.05 %/°C
Time Delay Range
  • 0.05...1 s
  • 30...300 h
  • 30...300 min
  • 30...300 s
  • 3...30 min
  • 1...10 s
  • 3...30 s
  • 0.3...3 s
  • 10...100 s
  • 3...30 h
Minimum Switching Current 10 mA 5 V DC
Overvoltage Category III IEC 60664-1
Input Voltage <= 2.4 V
Mounting Support 35 mm DIN rail conforming to IEC 60715
Electrical Durability
  • 100000 cycles, 8 A at 250 V, AC-1
  • 100000 cycles, 2 A at 24 V, DC-1
Mechanical Durability 10000000 cycles
Housing Material self-extinguishing
Status Led
  • Green LED backlight steady)dial pointer indication
  • Yellow LED steady)output relay energised
  • Yellow LED fast flashing)timing in progress and output relay de-energised
  • Yellow LED slow flashing)timing in progress and output relay energised
[Uimp] Rated Impulse Withstand Voltage 5 kV 1.2-50 µs IEC 60664-1
Width 22.5 mm
Time Delay Type symmetrical flashing
Tightening Torque 0.6-1 N.m IEC 60947-1
Supply Frequency 50...60 Hz +/- 5 %
Repeat Accuracy +/- 0.5 % IEC 61812-1
Product Certifications
  • GL
  • EAC
  • UL
  • CCC
  • CSA
  • CE
  • RCM
Ambient Air Temperature For Operation -20-60 °C
Standards
  • UL 508
  • IEC 61812-1
Electromagnetic Compatibility
  • fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
  • surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
  • surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
  • electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
  • electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
  • radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3
  • conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6
  • fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
  • immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
  • immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Dielectric Strength 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
Shock Resistance
  • 15 gn not operating 11 ms IEC 60068-2-27
  • 5 gn in operation 11 ms IEC 60068-2-27
Vibration Resistance 20 m/s² 10-150 Hz)IEC 60068-2-6
Pollution Degree 3 IEC 60664-1
Directives
  • 2004/108/EC - electromagnetic compatibility
  • 2006/95/EC - low voltage directive
Ambient Air Temperature For Storage -40-70 °C
Relative Humidity 95-95 % 25-55 °C
Ip Degree Of Protection
  • IP40 housing: conforming to IEC 60529
  • IP50 front face: conforming to IEC 60529
  • IP20 terminals: conforming to IEC 60529
Documents