This Harmony RE17R timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 8A, is 17.5mm wide and can be supplied with 24 V DC, 24 to 240 V AC. It also has 1 changeover contact SPDT (single pole double throw). It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. This timer offers pause and summation control signals. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0 0

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Discrete Output Type relay
Range Of Product Harmony Timer Relays
Product Or Component Type dual function relay
Time Delay Range
  • 1...10 min
  • 10...100 h
  • 0.1...1 s
  • 6...60 s
  • 6...60 min
  • 1...10 s
  • 1...10 h
Nominal Output Current 8 A
Width 17.5 mm
Time Delay Type power on-delay
Device Short Name RE17R
Safety Reliability Data
  • B10d = 270000
  • MTTFd = 296.8 years
Setting Accuracy Of Time Delay +/- 10 % of full scale 25 °C IEC 61812-1
Height 90 mm
Creepage Distance 4 kV/3 IEC 60664-1
Maximum Delay Response 100 ms
Control Type selector switch front panel
Insulation Resistance 100 MOhm 500 V DC IEC 60664-1
Maximum Power Consumption In W 0.6 W 24 V DC
Maximum Switching Current 8 A AC/DC
Contacts Material cadmium free
Power Consumption In Va 0-32 VA 240 V AC
Dielectric Strength 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
Marking CE
Voltage Range 0.85...1.1 Us
Reset Time 120 ms on de-energisation typical
Operating Rate In Hz 10 Hz
Net Weight 0.07 kg
Mounting Position any position in relation to normal vertical mounting plane
Voltage Drift +/- 0.2 %/V
Maximum Switching Voltage 250 V AC
Connections - Terminals
  • screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
  • screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
  • screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
Functionality on-delay timing
Contacts Type And Composition 1 C/O
[Us] Rated Supply Voltage
  • 24...240 V AC 50/60 Hz
  • 24 V DC
Temperature Drift +/- 0.05 %/°C
Local Signalling
  • LED indicator on steady: relay energised, no timing in progress
  • LED indicator 80 % ON and 20 % OFF flashing: timing in progress
  • LED indicator 5 % ON and 95 % OFF pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L)
Minimum Switching Current 10 mA 5 V DC
Input Voltage 10 V
Mounting Support 35 mm DIN rail conforming to EN/IEC 60715
Electrical Durability 100000 cycles resistive 8 A 250 V AC
Mechanical Durability 10000000 cycles
Compatibility Code RE17
Breaking Capacity 2000 VA
On-Load Factor 100 %
Housing Material self-extinguishing
Impulse Duration
  • 100 ms with load in parallel typical
  • 30 ms typical
Time Delay Type A, At
[Uimp] Rated Impulse Withstand Voltage 5 kV 1.2/50 µs
Depth 72 mm
Tightening Torque 0.6-1 N.m IEC 60947-1
Supply Frequency 50...60 Hz +/- 5 %
Repeat Accuracy +/- 0.5 % IEC 61812-1
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP121117EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI121113EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications
  • CSA
  • cULus
  • GL
Ambient Air Temperature For Operation -20-60 °C
Standards
  • 2006/95/EC
  • 2004/108/EC
  • IEC 61812-1
  • EN 61000-6-3
  • EN 61000-6-1
  • EN 61000-6-4
  • EN 61000-6-2
Immunity To Microbreaks 20 ms
Electromagnetic Compatibility
  • electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2
  • electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2
  • susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3
  • electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4
  • electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4
  • 1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5
  • 1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5
  • conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6
  • voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11
  • voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11
  • conducted and radiated emissionsclass B EN 55022
Shock Resistance 15 gn 11 ms IEC 60068-2-27
Vibration Resistance 20 m/s² 10-150 Hz)IEC 60068-2-6
Ip Degree Of Protection
  • IP20 IEC 60529 terminal block)
  • IP40 IEC 60529 housing)
  • IP50 IEC 60529 front panel)
Ambient Air Temperature For Storage -30-60 °C
Relative Humidity 93-93 % without condensation IEC 60068-2-30