QO generator panels are for the manual transfer from utility to generator power. QO generator panels are for back-up power applications. This sub-panel connects directly to the main load center and provides four single pole spaces that will accommodate up to eight circuits dedicated for back-up power. This QO generator panel uses two factory installed, two pole QO circuit breakers. One is fed by the utility, while the second circuit breaker is back-fed to the back-up power source, such as a generator. Power source switching is easy. Simply turn the main power breaker to the "OFF" position and then turn the generator fed breaker to the "ON" position. A factory installed mechanical interlock prevents both main breakers being in the "ON" position at the same time. This NEMA 1 enclosure with a surface cover with a door is for indoor applications. This panel has a 30A rating and a 10 kA short circuit current rating. The lugs will accept 14 AWG to 8 AWG copper or aluminum wire. This QO generator panel has a height of 12.57 inches, a width of 8.88 inches and a depth of 3.80 inches. This generator panel is UL Listed.
Brand: Schneider Electric
Add to Quote Catalogue| Product Certifications | UL Listed |
|---|---|
| Ambient Air Temperature For Operation |
|
| Nema Degree Of Protection | NEMA 1 indoor enclosure |
| Warranty | 18 months |
| Rohs Exemption Information | Yes |
| Mercury Free | Yes |
| Environmental Disclosure | ENVPEP2212001 |
| Sustainable Offer Status | Green Premium product |
| Toxic Heavy Metal Free | Yes |
| California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
| Reach Free Of Svhc | Yes |
| China Rohs Regulation | Pro-active China RoHS declaration (out of China RoHS legal scope) |
| Circularity Profile | N/A |
| Eu Rohs Directive | Compliant |
| Height | 319 mm |
| Phase | 1 phase 3 wires |
| Tightening Torque | Cover 20 lb.in |
| Electrical Connection | lugs |
| Number Of Circuits | 8 |
| Number Of Spaces | 4 |
| Short-Circuit Current | 10 kA |
| Number Of Tandem Circuit Breakers | 4 |
| Material | tin plated aluminium: busbar |
| Surface Finish | baked enamel Gray |
| Line Rated Current | 30 A |
| Enclosure Material | welded sheet steel |
| Awg Gauge | AWG 14...AWG 8 aluminium/copper |
| Width | 226 mm |
| Depth | 97 mm |
| Load Center Type | main breaker |
| Device Composition | grounding bar (ordered separately) |
| Box Number | 4 |
| Country of Origin | Mexico |
| Width | 226 mm |
| Height | 319 mm |
| Range Of Product | QO |
| Product Or Component Type | panel |
| Cover Type | surface cover with door |