Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
MPU15T2F – Unit substation, Mini Power-Zone, plug on, 15kVA, 3 phase, 480V primary, 208Y/120V secondary, 18kA, C
MPU15T2F
Unit substation, Mini Power-Zone, plug on, 15kVA, 3 phase, 480V primary, 208Y/120V secondary, 18kA, C

Square D™ brand Mini Power-Zone™ unit substation from Schneider Electric provides the answer to requirements for a portable, compact power supply for small loads. The Mini Power-Zone unit substation uses a separate transformer and panel section. This allows the panel section to be removed and wired first if desired. These transformers can be replaced without disturbing the panel section and associated wiring. The new transformer simply slides into the top of the panel section and primary and secondary leads are reconnected to the main circuit breakers. The panel section uses Square D™ brand QO™ style circuit breakers. Use Qwik-Gard™ circuit breakers for required ground fault protection. This Mini Power-Zone Sealed Transformer is a 1 phase, with a primary voltage of 480V and a secondary voltage of 208Y/120V with 2 tap offs @5 % FCBN taps. This transformer has a box number C and a insulation temperature rating of 185 °C. These transformers are installed on the interior of the load center that has 27 spaces. With a rated power of 15kVA, it has a short circuit current of 18kA. This transformer has a temperature rise of 115°C and is epoxy-resin encapsulated. The enclosure material is hot-rolled steel and is rated at NEMA 3R. This transformer complies to UL listed standards. This product comes with an 18 month warranrty.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Country of Origin United States
Width 695.96 mm
Height 1148.08 mm
Weight 231.33 kg
Product Certifications UL Listed
Primary Voltage 480 V
Range Of Product Mini Power-Zone
Secondary Voltage 208Y/120 V
Circuit Breaker Application
  • feeder breaker
  • primary main breaker
  • secondary main breaker
Board Name QO Load Center interior
Temperature Rise 115 °C
Number Of Tap-Offs 2 5 % FCBN
Product Or Component Type Sealed Transformer
Number Of Circuits 27
Number Of Spaces 27
Phase 3 phase
Material copper
Rated Power In Va 15 kVA
Short-Circuit Current 18 kA
Nema Degree Of Protection NEMA 3R hot-rolled steel
Box Number C
Insulation Temperature 185 °C
Height 1148.08 mm
Net Weight 231.33 kg
Width 695.96 mm
Depth 342.9 mm
California Proposition 65 WARNING: This product can expose you to chemicals including: Nickel (Metallic), which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive Under investigation
Warranty 18 months
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews