Specifications
Communication Network Type IPv6 (internet protocol)
Network Frequency
  • 50 Hz
  • 60 Hz
Communication Port Support
  • ETHERNET
  • screw terminal block RS485
Power Quality Analysis
  • EN 50160 2010 compliance report
  • IEEE 519 2014 compliance report
  • IEC 61000-4-30 class A power quality measurement
  • up to the 63rd harmonic
  • IEC 61000-4-15 harmonic distortion
  • EN 50160 2010 waveform capture
  • IEEE 519 2014 voltage sag and swell detection
  • programmablity (logic and math functions)
  • IEC 62586 power quality monitoring
  • disturbance direction detection
  • IEC 61000-4-15 flicker
  • rapid voltage change
Height 96 mm
Measurement Voltage
  • 57-400 V AC 42...69 Hz between phase and neutral
  • 100-690 V AC 42...69 Hz between phases
Sampling Rate 512 samples/cycle
Standards
  • IEC 61557-12
  • IEC 62052-11
  • IEC 62053-24
  • IEC 62053-22
  • IEEE 1588
  • IEC 62586-2
  • IEC 61326-1
Memory Capacity 512 MB
Number Of Outputs 1 pulse
Product Certifications
  • CE
  • cULus
  • N998
Type Of Measurement
  • current per phase, rms
  • voltage
  • frequency total
  • active and reactive power total
  • apparent power total
  • power factor total
  • active and reactive power per phase, rms
  • apparent power per phase, rms
  • power factor per phase, rms
Communication Port Protocol
  • Modbus RTU 115 kbauds - 2-wire
  • ION 115 kbauds - 2-wire
  • DNP3
  • IEC 61850
  • Modbus TCP/IP
  • Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
  • RSTP 801.1d 2004
Frequency Measurement Range 42-69 Hz
Communication Service
  • SMTP e-mail notification
  • RSTP support
  • NTP time synchronization
  • DHCP
  • PTP time synchronization
Power Consumption In Va 16 VA 230 V AC
Display Resolution 320 x 240 pixels QVGA
Number Of Inputs
  • 3 digital 30 V AC
  • 3 digital 60 V DC
Net Weight 581 g
Depth 77.5 mm
Measurement Current 50-10000 mA
Information Displayed
  • voltage
  • current
  • frequency
  • power
  • energy consumption
  • harmonic distortion
[Us] Rated Supply Voltage
  • 90...415 V AC 45...65 Hz +/- 10 %
  • 110...415 V DC +/- 10 %
Mounting Mode flush-mounted
Measurement Accuracy
  • current +/- 0.1 %
  • voltage +/- 0.1 %
  • active energy +/- 0.2 %
Mounting Support framework
Poles Description
  • 3P + N
  • 3P
  • 1P + N
Data Recording
  • min/max of instantaneous values
  • waveform logs
  • sequence of event recording
  • time stamping
  • alarm logs
  • trending/forecasting
  • sag and swell logs
  • harmonics logs
  • GPS synchronisation
  • data logs
  • event logs
  • 64 data recorders
Line Rated Current
  • 1 A
  • 5 A
  • 10 A
Cybersecurity
  • enable/disable communication ports
  • password protection
  • Syslog protocol support
  • robust security logs
  • port hardening
Isolation Voltage
  • III400-690 V conforming to IEC 61010-1:ed. 3
  • III400-690 V conforming to EN 61010-1:ed. 3
  • III347-600 V conforming to UL 61010-1:ed. 3
  • III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
Analogue Input Type
  • voltage (impedance 5 MOhm)
  • current (impedance 0.3 mOhm)
Web Services
  • customizable home page
  • file upload/download via FTP
  • file upload/download via SFTP
  • web server
  • alarm notification by e-mail
  • viewing of captured waveform (FTP)
  • viewing of captured waveform (web)
  • HTTPS server
Width 96 mm
Display Type colour TFT LCD
Device Application
  • power monitoring
  • WAGES metering
Accuracy Class
  • class 0.2S active energy IEC 62053-22
  • class 0.2 active energy ANSI C12.20
  • class 0.2 active power IEC 61557-12
  • class 0.5S reactive energy IEC 62053-24
  • class 0.5 power factor IEC 61557-12
  • class 0.2 voltage IEC 61557-12
  • class 0.2 current IEC 61557-12
Installation Category III
Width 96 mm
Height 96 mm
Weight 581 g
Variant advanced
Product Or Component Type power meter
Product Name PowerLogic PM8000
Range PowerLogic
Device Short Name PM8340
Ambient Air Temperature For Operation -25-70 °C
Electromagnetic Compatibility
  • electrostatic discharge conforming to IEC 61000-4-2
  • radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
  • electrical fast transient/burst immunity test conforming to IEC 61000-4-4
  • surge immunity test conforming to IEC 61000-4-5
  • conducted RF disturbances conforming to IEC 61000-4-6
  • magnetic field at power frequency conforming to IEC 61000-4-8
  • voltage dips and interruptions immunity test conforming to IEC 61000-4-11
  • immunity to impulse waves conforming to IEC 61000-4-12
  • conducted and radiated emissions (2...150 Hz) conforming to EN 55022
  • conducted and radiated emissions conforming to EN 55011
  • conducted and radiated emissions conforming to FCC part 15
  • conducted and radiated emissions conforming to ICES-003
  • conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579
  • surge withstand conforming to IEEE C37.90.1
Ambient Air Temperature For Storage -40-85 °C
Relative Humidity 5-95 %
Ip Degree Of Protection
  • IP54 front: conforming to IEC 60529
  • IP30 body: conforming to IEC 60529
Operating Altitude 9842.52 ft (3000 m)
Rohs Exemption Information Yes
Environmental Disclosure ENVPEP1406023EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI1406023EN
Eu Rohs Directive Compliant with Exemptions
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews