Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
LC1G1504LSEN – Contactor, high power, TeSys Giga, 4P(4NO), AC-1,
LC1G1504LSEN
Contactor, high power, TeSys Giga, 4P(4NO), AC-1, <=440V 275A, standard version, 200-500V AC/DC wide band coil
Specifications
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP2105013
Sustainable Offer Status Green Premium product
California Proposition 65 WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation X
Circularity Profile ENVEOLI2105013
Eu Rohs Directive Compliant with Exemptions
Ambient Air Temperature For Operation -25-60 °C
Ambient Air Temperature For Storage -60-80 °C
Protective Treatment TH
Ip Degree Of Protection
  • IP2X front face with shrouds IEC 60529
  • IP2X front face with shrouds VDE 0106
Mechanical Robustness
  • vibrations 5-300 Hz 2 gn contactor open
  • vibrations 5-300 Hz 4 gn contactor closed
  • shocks 10 gn 11 ms contactor open
  • shocks 15 gn 11 ms contactor closed
Color dark grey
Permissible Ambient Air Temperature Around The Device -40-70 °C at Uc
Country of Origin China
Width 143 mm
Height 193 mm
Weight 4.4 kg
[Uc] Control Circuit Voltage
  • 200...500 V AC 50/60 Hz
  • 200...500 V DC
[Ue] Rated Operational Voltage
  • <= 1000 V AC 50/60 Hz
  • <= 460 V DC
Range Of Product TeSys Giga
Control Circuit Voltage Limits
  • operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C)
  • drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
Contactor Application power switching
Product Or Component Type contactor
Range TeSys
Utilisation Category
  • AC-3
  • AC-3e
  • AC-1
  • AC-5a
  • AC-5b
  • AC-6a
  • AC-6b
  • DC-1
  • DC-3
  • DC-5
[Ie] Rated Operational Current
  • 150 A (at <60 °C) at <= 440 V AC-3
  • 275 A (at <40 °C) at <= 1000 V AC-1
Poles Description 4P
Device Short Name LC1G
Product Certifications
  • CB Scheme
  • CCC
  • cULus
  • EAC
  • CE
  • UKCA
  • EU-RO-MR by DNV-GL
Height 193 mm
Power Dissipation Per Pole
  • 10 W AC-1 - Ith 275 A
  • 5 W AC-3 - Ith 150 A
Average Impedance 0.00018 Ohm
Auxiliary Contact Composition 1 NO + 1 NC
Connection Pitch 35 mm
[Ith] Conventional Free Air Thermal Current 275 A (at 40 °C)
Mounting Support plate
Standards
  • EN/IEC 60947-4-1
  • EN/IEC 60947-5-1
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1
  • JIS C8201-4-1
  • JIS C8201-5-1
  • UL 60335-1
  • UL 60335-2-40:Annex JJ
Safety Reliability Level
  • B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1
  • B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Hold-In Power Consumption In W 8-8 W
Rated Breaking Capacity 1280 A at 440 V
Irms Rated Making Capacity 1890 A at 440 V
Associated Fuse Rating
  • 160 A aM at <= 440 V for motor
  • 160 A aM at <= 690 V for motor
  • 315 A gG at <= 690 V
Net Weight 4.4 kg
[Uimp] Rated Impulse Withstand Voltage 8 kV
Inrush Power In Va 295-295 VA
Pole Contact Composition 4 NO
Connections - Terminals
  • power circuit: bar 2 - busbar cross section: 25 x 6 mm
  • power circuit: lugs-ring terminals 1 185-185 mm²
  • control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end
  • control circuit: push-in 1 0.25-2.5 mm² - cable stiffness: flexible with cable end
  • control circuit: push-in 2 0.5-1.0 mm² with cable end
  • control circuit: push-in 0.75-2.5 mm² - cable stiffness: solid stranded without cable end
  • control circuit: push-in 0.75-2.5 mm² - cable stiffness: flexible with cable end
Coil Technology built-in bidirectional peak limiting
Operating Time
  • 40...70 ms closing
  • 15...50 ms opening
Maximum Operating Rate
  • 600 cyc/h AC-3
  • 600 cyc/h AC-3e
  • 300 cyc/h AC-1
Mechanical Durability 8 Mcycles
Tightening Torque 18 N.m
Compatibility Code LC1G
Hold-In Power Consumption In Va 13-13 VA
Width 143 mm
Overvoltage Category III
Depth 193 mm
[Ui] Rated Insulation Voltage 1000 V
Inrush Power In W 215 W
[Icw] Rated Short-Time Withstand Current
  • 1.2 kA - 10 s
  • 0.7 kA - 30 s
  • 0.6 kA - 1 min
  • 0.45 kA - 3 min
  • 0.35 kA - 10 min
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews