LC1D95X6 – Contactor, TeSys Deca, 3P 95A AC-3,
LC1D95X6
Contactor, TeSys Deca, 3P 95A AC-3, <= 440V, aux 1NO+1NC, 600V AC 60Hz coil, screw clamp terminals
Specifications
Product Certifications
  • CCC
  • UL
  • CB Scheme
  • CSA
  • CE
  • UKCA
  • Marine
  • EAC
Height 127 mm
Standards
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • CSA C22.2 No 14
  • UL 60947-4-1
  • IEC 60335-2-40:Annex JJ
  • UL 60335-2-40:Annex JJ
  • IEC 60335-1:Clause 30.2
Climatic Withstand IACS E10 exposure to damp heat
Net Weight 1.61 kg
Flame Retardance V1 conforming to UL 94
Protective Treatment TH 3)IEC 60068-2-30
Ip Degree Of Protection IP20 IEC 60529
Mechanical Robustness
  • shocks contactor opened 8 Gn for 11 ms)
  • shocks contactor closed 10 Gn for 11 ms)
  • vibrations contactor opened 2 Gn, 5...300 Hz)
  • vibrations contactor closed 3 Gn, 5...300 Hz)
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 850 °C IEC 60695-2-1
Width 85 mm
Depth 130 mm
Warranty 18 months
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP110205EN
Sustainable Offer Status Green Premium product
Toxic Heavy Metal Free Yes
Reach Free Of Svhc Yes
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile N/A
Sustainable Packaging Yes
Eu Rohs Directive Compliant
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contacts
  • 1.5 ms on energisation between NC and NO contacts
Minimum Switching Current 5 mA for signalling circuit
Power Dissipation Per Pole
  • 12.5 W AC-1
  • 7.2 W AC-3
Average Impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
  • 10 A (at 60 °C) for signalling circuit
  • 125 A (at 60 °C) for power circuit
Control Circuit Voltage Limits
  • 0.3...0.6 Uc -40-70 °C drop-out AC 60 Hz
  • 0.85...1.1 Uc -40-55 °C operational AC 60 Hz
  • 1...1.1 Uc 55-70 °C operational AC 60 Hz
Mounting Support
  • rail
  • plate
Control Circuit Type AC 60 Hz
Safety Reliability Level
  • B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance > 10 MOhm for signalling circuit
Rated Breaking Capacity 1100 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity
  • 1100 A at 440 V AC for power circuit conforming to IEC 60947
  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
  • 250 A DC for signalling circuit conforming to IEC 60947-5-1
Associated Fuse Rating
  • 10 A gG for signalling circuit conforming to IEC 60947-5-1
  • 160 A gG at <= 690 V coordination type 2 for power circuit
  • 200 A gG at <= 690 V coordination type 1 for power circuit
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
Inrush Power In Va 220-220 VA 60 Hz cos phi 0.75 (at 20 °C)
Pole Contact Composition 3 NO
Connections - Terminals
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end
  • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
  • power circuit: screw terminals 1 4-50 mm² - cable stiffness: rigid
  • power circuit: screw terminals 2 4-25 mm² - cable stiffness: rigid
  • power circuit: screw terminals 1 4-50 mm² - cable stiffness: flexible without cable end
  • power circuit: screw terminals 2 4-25 mm² - cable stiffness: flexible without cable end
  • power circuit: screw terminals 1 4-50 mm² - cable stiffness: flexible with cable end
  • power circuit: screw terminals 2 4-16 mm² - cable stiffness: flexible with cable end
Coil Technology without built-in suppressor module
Operating Time
  • 20...35 ms closing
  • 6...20 ms opening
Minimum Switching Voltage 17 V for signalling circuit
Maximum Operating Rate 3600 cyc/h at 60 °C
Tightening Torque
  • control circuit 1.2 N.m screw clamp terminal flat Ø 6 mm
  • control circuit 1.2 N.m screw clamp terminal Philips No 2
  • power circuit 12 N.m screw terminal flat Ø 6 to Ø 8 mm
  • power circuit 12 N.m screw terminal hex (Allen key) 4 mm
  • control circuit 1.2 N.m screw clamp terminal pozidriv No 2
Electrical Durability
  • 1.2 Mcycles 95 A AC-3
  • 1.3 Mcycles 125 A AC-1
Mechanical Durability 10 Mcycles
Auxiliary Contacts Type
  • mechanically linked 1 NO + 1 NC IEC 60947-5-1
  • mirror contact 1 NC IEC 60947-4-1
Compatibility Code LC1D
Hold-In Power Consumption In Va 22-22 VA 60 Hz cos phi 0.3 (at 20 °C)
Overvoltage Category III
Maximum Horse Power Rating
  • 7.5 hp at 115 V AC 60 Hz for 1 phase motors
  • 15 hp at 230/240 V AC 60 Hz for 1 phase motors
  • 25 hp at 200/208 V AC 60 Hz for 3 phase motors
  • 30 hp at 230/240 V AC 60 Hz for 3 phase motors
  • 60 hp at 460/480 V AC 60 Hz for 3 phase motors
  • 60 hp at 575/600 V AC 60 Hz for 3 phase motors
Motor Power Kw
  • 25 kW at 220...230 V AC 50 Hz (AC-3)
  • 45 kW at 380...400 V AC 50 Hz (AC-3)
  • 45 kW at 415...440 V AC 50 Hz (AC-3)
  • 55 kW at 500 V AC 50 Hz (AC-3)
  • 45 kW at 660...690 V AC 50 Hz (AC-3)
  • 15 kW at 400 V AC 50 Hz (AC-4)
  • 25 kW at 220...230 V AC 50 Hz (AC-3e)
  • 45 kW at 380...400 V AC 50 Hz (AC-3e)
  • 45 kW at 415...440 V AC 50 Hz (AC-3e)
  • 55 kW at 500 V AC 50 Hz (AC-3e)
  • 45 kW at 660...690 V AC 50 Hz (AC-3e)
[Ui] Rated Insulation Voltage
  • power circuit 1000 V IEC 60947-4-1
  • power circuit 600 V CSA
  • power circuit 600 V UL
  • signalling circuit 690 V IEC 60947-1
  • signalling circuit 600 V CSA
  • signalling circuit 600 V UL
[Icw] Rated Short-Time Withstand Current
  • 1100 A 40 °C - 1 s for power circuit
  • 800 A 40 °C - 10 s for power circuit
  • 400 A 40 °C - 1 min for power circuit
  • 135 A 40 °C - 10 min for power circuit
  • 140 A - 100 ms for signalling circuit
  • 120 A - 500 ms for signalling circuit
  • 100 A - 1 s for signalling circuit
Heat Dissipation 6-10 W at 60 Hz for control circuit
Protective Cover with
Country of Origin Czechia
Width 85 mm
Height 127 mm
Weight 1.61 kg
[Uc] Control Circuit Voltage 600 V AC 60 Hz
[Ue] Rated Operational Voltage power circuit <= 690 V AC 25...400 Hz
Range Of Product TeSys Deca
Contactor Application
  • motor control
  • resistive load
Product Or Component Type contactor
Range TeSys
Utilisation Category
  • AC-3
  • AC-3e
  • AC-4
  • AC-1
[Ie] Rated Operational Current
  • 95 A (at <60 °C) at <= 440 V AC-3 for power circuit
  • 125 A (at <60 °C) at <= 690 V AC-1 for power circuit
Poles Description 3P
Device Short Name LC1D
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews