| Product Certifications |
|
|---|---|
| Height | 127 mm |
| Standards |
|
| Climatic Withstand | IACS E10 exposure to damp heat |
| Net Weight | 1.61 kg |
| Flame Retardance | V1 conforming to UL 94 |
| Protective Treatment | TH 3)IEC 60068-2-30 |
| Ip Degree Of Protection | IP20 IEC 60529 |
| Mechanical Robustness |
|
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Fire Resistance | 850 °C IEC 60695-2-1 |
| Width | 85 mm |
| Depth | 130 mm |
| Warranty | 18 months |
| Rohs Exemption Information | Yes |
| Mercury Free | Yes |
| Environmental Disclosure | ENVPEP110205EN |
| Sustainable Offer Status | Green Premium product |
| Toxic Heavy Metal Free | Yes |
| Reach Free Of Svhc | Yes |
| Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| China Rohs Regulation | Pro-active China RoHS declaration (out of China RoHS legal scope) |
| Circularity Profile | N/A |
| Sustainable Packaging | Yes |
| Eu Rohs Directive | Compliant |
| Non-Overlap Time |
|
| Minimum Switching Current | 5 mA for signalling circuit |
| Power Dissipation Per Pole |
|
| Average Impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| [Ith] Conventional Free Air Thermal Current |
|
| Control Circuit Voltage Limits |
|
| Mounting Support |
|
| Control Circuit Type | AC 60 Hz |
| Safety Reliability Level |
|
| Insulation Resistance | > 10 MOhm for signalling circuit |
| Rated Breaking Capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| Irms Rated Making Capacity |
|
| Associated Fuse Rating |
|
| [Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947 |
| Inrush Power In Va | 220-220 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Pole Contact Composition | 3 NO |
| Connections - Terminals |
|
| Coil Technology | without built-in suppressor module |
| Operating Time |
|
| Minimum Switching Voltage | 17 V for signalling circuit |
| Maximum Operating Rate | 3600 cyc/h at 60 °C |
| Tightening Torque |
|
| Electrical Durability |
|
| Mechanical Durability | 10 Mcycles |
| Auxiliary Contacts Type |
|
| Compatibility Code | LC1D |
| Hold-In Power Consumption In Va | 22-22 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Overvoltage Category | III |
| Maximum Horse Power Rating |
|
| Motor Power Kw |
|
| [Ui] Rated Insulation Voltage |
|
| [Icw] Rated Short-Time Withstand Current |
|
| Heat Dissipation | 6-10 W at 60 Hz for control circuit |
| Protective Cover | with |
| Country of Origin | Czechia |
| Width | 85 mm |
| Height | 127 mm |
| Weight | 1.61 kg |
| [Uc] Control Circuit Voltage | 200 V AC 60 Hz |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hz |
| Range Of Product | TeSys Deca |
| Contactor Application |
|
| Product Or Component Type | contactor |
| Range | TeSys |
| Utilisation Category |
|
| [Ie] Rated Operational Current |
|
| Poles Description | 3P |
| Device Short Name | LC1D |
Powered by ![]()
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366