Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
LC1D40E7 – IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48VAC 50/60Hz coil, open
LC1D40E7
IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48VAC 50/60Hz coil, open

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 48 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Certifications
  • GL
  • BV
  • DNV
  • LROS (Lloyds register of shipping)
  • RINA
  • UL
  • CCC
  • CSA
  • GOST
  • UKCA
  • CB
Height 127 mm
Standards
  • EN 60947-4-1
  • IEC 60947-4-1
  • EN 60947-5-1
  • UL 508
  • IEC 60947-5-1
  • CSA C22.2 No 14
Climatic Withstand IACS E10 exposure to damp heat
Net Weight 1.4 kg
Flame Retardance V1 conforming to UL 94
Ip Degree Of Protection
  • IP2X IEC 60529
  • IP2X VDE 0106
Mechanical Robustness
  • shocks contactor opened 10 Gn for 11 ms)
  • shocks contactor closed 15 Gn for 11 ms)
  • vibrations contactor opened 2 Gn, 5...300 Hz)
  • vibrations contactor closed 4 Gn, 5...300 Hz)
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 850 °C IEC 60695-2-1
Width 75 mm
Depth 119 mm
Warranty 18 months
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP110205EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Toxic Heavy Metal Free Yes
California Proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile N/A
Eu Rohs Directive Compliant
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contacts
  • 1.5 ms on energisation between NC and NO contacts
Minimum Switching Current 5 mA for control circuit
Power Dissipation Per Pole
  • 5.4 W AC-1
  • 2.4 W AC-3
  • 2.4 W AC-3e
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
  • 10 A (at 60 °C) for control circuit
  • 60 A (at 60 °C) for power circuit
Control Circuit Voltage Limits
  • 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz
  • 0.8...1.1 Uc -40-60 °C operational AC 50 Hz
  • 0.85...1.1 Uc -40-60 °C operational AC 60 Hz
  • 1...1.1 Uc 60-70 °C operational AC 50/60 Hz
Mounting Support
  • rail
  • plate
Control Circuit Type AC 50/60 Hz
Safety Reliability Level
  • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance > 10 MOhm for control circuit
Rated Breaking Capacity 800 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity
  • 800 A at 440 V for power circuit conforming to IEC 60947
  • 140 A AC for control circuit conforming to IEC 60947-5-1
Associated Fuse Rating
  • 10 A gG for control circuit conforming to IEC 60947-5-1
  • 80 A gG at <= 690 V coordination type 1 for power circuit
  • 80 A gG at <= 690 V coordination type 2 for power circuit
Inrush Power In Va
  • 140-140 VA cos phi 0.75 (at 20 °C)
  • 160-160 VA cos phi 0.75 (at 20 °C)
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
Pole Contact Composition 3 NO
Connections - Terminals
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end
  • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
  • power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: rigid
  • power circuit: screw terminals 2 2.5-16 mm² - cable stiffness: rigid
  • power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end
  • power circuit: screw terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end
  • power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end
  • power circuit: screw terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end
Coil Technology without built-in bidirectional peak limiting diode suppressor
Operating Time
  • 4...19 ms opening
  • 12...26 ms closing
Minimum Switching Voltage 17 V for control circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque
  • control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm
  • control circuit 1.7 N.m screw clamp terminal Philips No 2
  • power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm
  • control circuit 1.7 N.m screw clamp terminal pozidriv No 2
Mechanical Durability 6000000 cycles
Auxiliary Contacts Type
  • mechanically linked 1 NO + 1 NC IEC 60947-5-1
  • mirror contact 1 NC IEC 60947-4-1
Compatibility Code LC1D
Hold-In Power Consumption In Va
  • 13-13 VA 60 Hz cos phi 0.3 (at 20 °C)
  • 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
Overvoltage Category III
Maximum Horse Power Rating
  • 3 hp at 115 V AC 60 Hz for 1 phase motors
  • 5 hp at 230/240 V AC 60 Hz for 1 phase motors
  • 10 hp at 200/208 V AC 60 Hz for 3 phase motors
  • 10 hp at 230/240 V AC 60 Hz for 3 phase motors
  • 30 hp at 460/480 V AC 60 Hz for 3 phase motors
  • 30 hp at 575/600 V AC 60 Hz for 3 phase motors
Motor Power Kw
  • 18.5 kW at 380...400 V AC 50 Hz (AC-3)
  • 22 kW at 500 V AC 50 Hz (AC-3)
  • 30 kW at 660...690 V AC 50 Hz (AC-3)
  • 22 kW at 1000 V AC 50 Hz (AC-3)
  • 22 kW at 415 V AC 50 Hz (AC-3)
  • 22 kW at 440 V AC 50 Hz (AC-3)
  • 11 kW at 220...230 V AC 50 Hz (AC-3)
  • 9 kW at 400 V AC 50 Hz (AC-4)
  • 18.5 kW at 380...400 V AC 50 Hz (AC-3e)
  • 22 kW at 500 V AC 50 Hz (AC-3e)
  • 30 kW at 660...690 V AC 50 Hz (AC-3e)
  • 22 kW at 1000 V AC 50 Hz (AC-3e)
  • 22 kW at 415 V AC 50 Hz (AC-3e)
  • 22 kW at 440 V AC 50 Hz (AC-3e)
  • 11 kW at 220...230 V AC 50 Hz (AC-3e)
[Ui] Rated Insulation Voltage
  • control circuit 600 V CSA
  • control circuit 600 V UL
  • power circuit 600 V CSA
  • power circuit 600 V UL
  • control circuit 690 V IEC 60947-1
  • power circuit 690 V IEC 60947-1
Heat Dissipation 4-5 W at 50/60 Hz for control circuit
Protective Cover with
Country of Origin France
Width 75 mm
Height 127 mm
Weight 1.4 kg
[Uc] Control Circuit Voltage 48 V AC 50/60 Hz
[Ue] Rated Operational Voltage power circuit <= 690 V AC 25...400 Hz
Range Of Product TeSys Deca
Contactor Application
  • resistive load
  • motor control
Product Or Component Type contactor
Range TeSys
Utilisation Category
  • AC-3
  • AC-1
  • AC-4
  • AC-2
  • AC-3e
[Ie] Rated Operational Current
  • 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
  • 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
  • 40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Poles Description 3P
Device Short Name LC1D
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews