EZM3600JCBA40 – Main circuit breaker busway center tap, EZ Meter-Pak, 600A, 240VAC max, 3ph/4W, 4000A bus, 100kA, Type 3R
EZM3600JCBA40
Main circuit breaker busway center tap, EZ Meter-Pak, 600A, 240VAC max, 3ph/4W, 4000A bus, 100kA, Type 3R

Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install.  Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices.  External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This busway center tap main circuit breaker provides 3 phases in, 3 phases out for a 4 wire configuration. It accepts 208Y/120VAC and 240/120VAC delta incoming service from busway feeds. The unit is rated for 600A with the busbar rated for 4000A. It has a short circuit current rating of 100kA. The enclosure is painted steel Type 3R. This EZ Meter-Pak meter center complies with UL standards.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Rohs Exemption Information Yes
Mercury Free Yes
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive Compliant with Exemptions
Width 27.95 in
Height 43.07 in
Range Of Product EZ meter-pak
Main Type Main Circuit Breaker
Provided Equipment
  • circuit-breaker 1 ) 3P 600 A 100 kA main supply, ready assembled
  • closing plate
Product Or Component Type meter centre busway centre tap main unit
Height 43.07 in
Phase
  • 3 phase in
  • 3 phase out
Device Mounting surface
[Ue] Rated Operational Voltage
  • 208Y/120 V AC
  • 240/120 V delta AC
Bus Rated Current 4000 A
Main Rated Current 600 A
Electrical Connection busway
Enclosure Material painted steel
Width 27.95 in
Wiring Configuration 4-wire
Depth 14.76 in
Product Certifications UL Listed
Nema Degree Of Protection NEMA 3R