Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install.  Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices.  External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This busway left tap main circuit breaker provides 3 phases in, 3 phases out for a 4 wire configuration. It accepts 208Y/120VAC and 240/120VAC delta incoming service from busway feeds with front neutral installation. The unit is rated for 1000A with the busbar rated for 1000A. It has a short circuit current rating of 65kA. The enclosure is painted steel Type 1. This EZ Meter-Pak meter center complies with UL standards.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Certifications UL Listed
Nema Degree Of Protection NEMA 1
Warranty 18 months
Rohs Exemption Information Yes
Mercury Free Yes
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive Compliant with Exemptions
Height 53.93 in
Phase
  • 3 phase in
  • 3 phase out
Device Mounting surface
[Ue] Rated Operational Voltage
  • 208Y/120 V AC
  • 240/120 V delta AC
Bus Rated Current 1000 A
Type Of Installation indoor
Main Rated Current 1000 A
Electrical Connection
  • lugsneutral front
  • busway left side
Enclosure Material painted steel
Width 18.66 in
Wiring Configuration 4-wire
Depth 11.41 in
Width 18.66 in
Height 53.93 in
Range Of Product EZ meter-pak
Main Type Main Circuit Breaker
Provided Equipment
  • circuit-breaker 1 ) 3P 1000 A 240 V AC 65 kA
  • closing plate
Product Or Component Type meter center main unit