                  | Mercury Free | Yes | 
|---|---|
| Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. | 
| China Rohs Regulation | X | 
| Upgradeability | Upgraded components available | 
| Environmental Disclosure | ENVPEP1707007EN | 
| California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov | 
| Circularity Profile | ENVEOLI1707007EN | 
| Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) | 
| Country of Origin | Indonesia | 
| Width | 171 mm | 
| Height | 409 mm | 
| Weight | 5.5 kg | 
| Prospective Line Isc | 70 kA | 
| Product Destination | 
 | 
| Line Current | 
 | 
| Emc Filter | without EMC filter | 
| Asynchronous Motor Control Profile | 
 | 
| Variant | standard version | 
| Product Or Component Type | variable speed drive | 
| Apparent Power | 
 | 
| Switching Frequency | 
 | 
| Communication Port Protocol | 
 | 
| Product Specific Application | process and utilities | 
| Safety Function | STO (safe torque off) SIL 3 | 
| Maximum Horse Power Rating | 
 | 
| Supply Frequency | 50...60 Hz - 5...5 % | 
| Option Card | 
 | 
| Degree Of Protection | UL type 1 UL 508C | 
| Range Of Product | Altivar Process ATV600 | 
| Speed Drive Output Frequency | 0.1-500 Hz | 
| Ip Degree Of Protection | 
 | 
| [Us] Rated Supply Voltage | 600 V - 15...10 % | 
| Discrete Input Logic | 16 preset speeds | 
| Type Of Cooling | forced convection | 
| Continuous Output Current | 
 | 
| Nominal Switching Frequency | 4 kHz | 
| Device Short Name | ATV630 | 
| Synchronous Motor Control Profile | 
 | 
| Discrete Input Logic | 
 | 
| Analogue Output Type | 
 | 
| Discrete Output Type | 
 | 
| Maximum Switching Current | 
 | 
| Exchange Mode | half duplex, full duplex, autonegotiation Ethernet/Modbus TCP | 
| Phase | 3 phase | 
| Net Weight | 5.5 kg | 
| Type Of Polarization | no impedance | 
| Frequency Resolution | 
 | 
| Relay Output Type | 
 | 
| Maximum Transient Current | 
 | 
| Analogue Input Number | 3 | 
| Motor Slip Compensation | 
 | 
| Discrete Output Number | 0 | 
| Method Of Access | slave Modbus TCP | 
| Discrete Input Number | 8 | 
| Local Signalling | 
 | 
| Linearity Error | 
 | 
| Number Of Addresses | 1-247 Modbus serial | 
| Width | 171 mm | 
| Transmission Rate | 
 | 
| Depth | 233 mm | 
| Analogue Input Type | 
 | 
| Sampling Duration | 
 | 
| Electrical Connection | 
 | 
| Maximum Output Frequency | 500 kHz | 
| Height | 409 mm | 
| Acceleration And Deceleration Ramps | 
 | 
| Transmission Frame | RTU | 
| Relay Output Number | 3 | 
| Data Format | 8 bits, configurable odd, even or no parity | 
| Accuracy | 
 | 
| Connector Type | 
 | 
| Input Compatibility | 
 | 
| Permissible Temporary Current Boost | 
 | 
| Mounting Mode | wall mount | 
| Analogue Output Number | 2 | 
| Physical Interface | 
 | 
| Minimum Switching Current | relay output R1, R2, R3 5 mA 24 V DC | 
| Refresh Time | relay output R1, R2, R3)5 ms +/- 0.5 ms) | 
| Enclosure Mounting | wall mounted | 
| Isolation | between power and control terminals | 
| Output Voltage | <= power supply voltage | 
| Quantity Per Set | 1 | 
| Braking To Standstill | by DC injection | 
| Discrete Input Type | DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) | 
| Protection Type | 
 | 
| Supply | 
 | 
| Product Certifications | 
 | 
| Power Dissipation In W | 
 | 
| Standards | 
 | 
| Insulation Resistance | > 1 MOhm 500 V DC for 1 minute to earth | 
| Shock Resistance | 15 gn 11 ms IEC 60068-2-27 | 
| Vibration Resistance | 
 | 
| Regulation Loop | adjustable PID regulator | 
| Operating Altitude | 
 | 
| Overvoltage Category | III | 
| Electromagnetic Compatibility | 
 | 
| Ambient Air Temperature For Operation | 
 | 
| Volume Of Cooling Air | 103 m3/h | 
| Pollution Degree | 2 IEC 61800-5-1 | 
| Noise Level | 56 dB | 
| Ambient Air Temperature For Storage | -40-70 °C | 
| Relative Humidity | 5-95 % without condensation IEC 60068-2-3 | 
| Operating Position | vertical +/- 10 degree | 
| Maximum Thdi | <48 % with external line choke IEC 61000-3-12 | 
Powered by 
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366