Well-Guard pumping plant panels are designed for pumping applications. These panels provide extra space for field installation of auxiliary equipment. These panels use Type S non-reversing magnetic starters. Panel has a 60A fusible disconnect switch for Class H or K fuses. This panel has a 3 pole NEMA Size 2 non-reversing starter that has a 45 ampere rating. This NEMA Size 2 starter has maximum of 15 HP, 20 HP and 25 HP ratings three phase. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 15A to 45A range to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 440/480 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 39.05 inches tall, 13.73 inches wide and 9.70 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Name Well-Guard Control
Device Application pumping
Device Short Name class 8940 type SS
Warranty 18 months
Thermal Overload Type Motor Logic solid state class 10/20
Disconnector Device Type fusible disconnect switch
Height 992 mm
Control Type
  • selector switch HAND-OFF-AUTO)
  • push-button START)
Nema Size 2
Device Mounting surface
Fuse Type H or K
Maximum Horse Power Rating 25-25 hp 480 V AC, 3 phase
[Uc] Control Circuit Voltage
  • 480 V AC 60 Hz
  • 440 V AC 50 Hz
Electrical Connection screw terminal
Line Rated Current 45 A
Protection Type
  • overload
  • phase loss
  • phase unbalance
Control Circuit common control circuit
Width 385 mm
Depth 246 mm
Permissible Voltage 600 V AC
Associated Fuse Rating 60 A
Number Of Poles 3
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Pvc Free Yes
Eu Rohs Directive Not compliant
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Product Certifications
  • UL Listed
  • NEMA
Nema Degree Of Protection NEMA 3R
Enclosure Type weatherproof enclosure indoor/outdoor