Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
4780.05010 – TC-Flex Tray Cable 14 AWG (2,5 mm ) – 10 AWG (6,0 mm )
4780.05010
TC-Flex Tray Cable 14 AWG (2,5 mm ) – 10 AWG (6,0 mm )
  • In free air, raceways or direct burial
  • UL) WTTC cables for use up to 1000 V in wind turbine generator applications in accordance with UL Subject 6140
  • UL) TC-ER cables for use up to 600 V as power and control cables in accordance with NEC® Article 336
  • UL) MTW cables for machine tool and wire up to 600 V as power and control cables in accordance with UL 1063
  • CSA) CIC/TC cables for use up to 600 V in cable trays and other applications when installed in accordance with the Canadian Electrical Code, Part I
  • CSA) AWM cables for use up to 1000 V as equipment wiring in accordance with the Canadian Electrical Code, Part I

Brand: Prysmian Group

Add to Quote
Description
Description TC-Flex Tray Cable 14 AWG (2,5 mm ) – 10 AWG (6,0 mm )
Applications
  • In free air, raceways or direct burial
  • UL) WTTC cables for use up to 1000 V in wind turbine generator applications in accordance with UL Subject 6140
  • UL) TC-ER cables for use up to 600 V as power and control cables in accordance with NEC® Article 336
  • UL) MTW cables for machine tool and wire up to 600 V as power and control cables in accordance with UL 1063
  • CSA) CIC/TC cables for use up to 600 V in cable trays and other applications when installed in accordance with the Canadian Electrical Code, Part I
  • CSA) AWM cables for use up to 1000 V as equipment wiring in accordance with the Canadian Electrical Code, Part I
Compliances
  • Design Adherence:
  • UL 66 & UL 83/CSA C22.2 No. 75-08
  • Thermoplastic Insulated Wires
  • UL 1063/MTW Machine Tool Wire
  • UL 1277 Power and Control Tray Cables
  • UL 2277 Wind Turbine Tray Cables
  • CSA C22.2 No. 230-09 Tray Cables
  • CSA C22.2 No. 239-09 Control and Instrumentation Cables
  • CSA C22.2 No. 210-11 Appliance Wiring Material Products
  • Flame Tests:
  • IEEE 1202/CSA FT4
  • Compliances:
  • Type TC-ER 90°C Dry, 75°C Wet, 600 V
  • Type MTW
  • Type WTTC 90°C, 1000 V
  • Type CIC/TC 90°C, 600 V
  • Type AWM I/II A/B, 90°C, 1000 V FT4
  • RoHS Compliant
Print
  • GENERAL CABLE® TC-FLEX™ XX/C XXAWG (XXMM2) (UL) TC-ER TYPE THHN/THWN 90˚C DRY 75˚C WET 600 V SUN RES DIR BUR OIL RES I/II OR MTW OR WTTC 1000 V 90˚C DRY c(UL) CIC/TC PVC/N 90˚C FT4 --- CSA AWM I/II A/B 90˚C 1000 V
  • ROHS CE – MADE IN USA DAY/MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE MARKER
Product Construction
Spec Number 4780
Conductor 14 AWG (2,5 mm²) thru 10 AWG (6,0 mm²) fully annealed flexible stranded bare copper with Class 5 stranding per EN 60228 (IEC 60228)
Conductor Identification Conductors are black with printed numbers and green/yellow grounding conductor
Insulation Polyvinyl Chloride (PVC) insulation with Polyamide (nylon) jacket per UL 83
Jacket Black, flexible, flame-retardant, sunlight- and oil- resistant Polyvinyl Chloride (PVC) jacket
Minimum Bending Radius
  • 4x O.D. for fixed installation
  • 8x O.D. for flexing applications
Torsion 10,000 cycles at -40°C, +/- 150° twist per meter, cable weight compensated to 20 meters
Specifications
Catalog Number 4780.05010
No. Of Cond. Inc. Grnd. 5
Nom. Ins. Thickness
  • 0.027 (Inches)
  • 0.69 (Mm)
Nom. Jacket Thickness
  • 0.063 (Inches)
  • 1.60 (Mm)
Nom. Cable O.D.
  • 0.618 (Inches)
Nom. Cable O.D.
  • 15.7 (Mm)
Nom. Copper Weight
  • 182 (Lbs/1000 Ft)
  • 271 (Kg/Km)
Nom. Cable Weight
  • 284 (Lbs/1000 Ft)
  • 422 (Kg/Km)
90°C Amp. @ 30°C Ambient 35
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews