Low voltage power factor correction solution, from VarSet family, helps to eliminate utility penalties. To do energy savings, to lower capital costs, and to reduce CO² emissions by the reactive power compensation of inductive loads. This hardware is compatible with power management software to take advantage of the IoT digital power installation and allow a seemless integration to EcoStruxture Power. Smart monitoring and measurement features are available to secure operations. To optimize perfomance and maintenance, across a broad range of applications, commercial or industrial. This capacitor bank version, suitable for network voltage 480V – 60Hz is providing a reactive power up to 550kvar, with a tuning frequency of 252Hz. The compensation is automatically adjusted by the Power factor controller from VarplusLogic family. It is designed for network harmonic voltage up to 7% or network harmonic current up to 20%. VarSet range is certified to CSA 22.2 No 190 and to UL 811. It is embedding high life expectancy capacitors from Varplus family designed as per IEC831 part 1, IEC831 part 2, UL810. And include a smart controller with modbus communication RS485. The enclosure is floorstanding type with a top entry incoming connection. Frame exterior dimensions are 1524 millimetres in width, 915 millimetres in depth, 2324 millimetres height and a max product weight of 1268kg. As a standard, the enclosures are NEMA 1 for indoor application. This product is particularly adapted for power factor correction applications with variable or unstable loads.
Add to Quote CataloguePart Number | AV055046CV5F2N |
---|---|
Availability | N |
Lead Time | 40 |
UNSPSC | 83101808 |
Discount Schedule | DE2C |
Return Indicator | No |
Depth | 36.02 inch |
Height | 60.00 inch |
Width | 60.00 inch |
Network Rated Voltage | 480 V AC 60 Hz |
---|---|
Reactive Power Rating | 550 kvar |
Operating Mode | Automatic & transient free |
Range Of Product | VarSet |
Device Short Name | VarSet detuned |
Product Or Component Type | Capacitor bank |
Controller Type | Varplus Logic VPL12 Modbus |
Capacitor Technology | VarPlus Can + Detuned reactor |
Accessibility For Operation | Front |
Colour | Gray ASA 49) |
Network Pollution Level | Low polluted |
[Thdv] Total Harmonic Distortion | 0…5 % |
Thdi | 0…8 % |
Tuning Factor | 4.2 |
Tuning Frequency | 252 Hz |
Power Per Step | 50 kvar |
Step Composition | 50 + 5x100 |
Location Of Connection | Top |
Internal Voltage Transformer | 480/120 V |
Poles Description | 3P |
Capacitance Tolerance | 5 % to 10 % |
Maximum Permissible Voltage | 1.1 x Un 8 hours over 24 hours) |
Protection Type | Main lug |
Incoming Connection Short Circuit Rating | 65 kA 4 cycles |
Maximum Weight | 2795.46 lb(US) (1268 kg) |
Height | 60.00 in (1524 mm) |
Width | 60.00 in (1524 mm) |
Depth | 36.02 in (915 mm) |
Mounting Location | Indoor |
Standards | CSA C22.2 No 190-M1985 |
Nema Degree Of Protection | NEMA 1 |
Mechanical Degree Of Protection | IK10 |
Relative Humidity | 0…95 % |
Operating Altitude | <= 6561.68 ft (2000 m) |
Ambient Air Temp For Op | 14…104 °F (-10…40 °C) |
Average Ambient Air Temp F Opr | 30 °C annual) |
Category | 00086 - VARSET AV6000 CTO LV CAP BANK (CTO) |
Discount Schedule | DE2C |
Nbr. Of Units In Pkg. | 1 |
EU RoHs Directive | Under investigation |
Powered by