Specifications
Part Number XMLPM00GD7BF
Country of Origin CH
UPC 389119624992
UPC11 38911962499
EAN 3389119624992
Availability N
Lead Time 35
ECCN EAR99
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule DS2
Return Indicator No
Weight 0.17 pound
Characteristics
Range Of Product OsiSense XM
Product Or Component Type Electronic pressure sensors
Pressure Sensor Type Pressure transmitter
Pressure Sensor Name XMLP
Electrical Circuit Type Control circuit
Pressure Sensor Size -14.50…0.00 psi (-1…0 bar)
Local Display Without
Controlled Fluid Fresh water 32…257 °F (0…125 °C)) Air 5…257 °F (-15…125 °C)) Gas 5…257 °F (-15…125 °C)) Hydraulic oil 5…257 °F (-15…125 °C))
Fluid Connection Type SAE 7/16-20UNF (female)
Electrical Connection 1 male connector M12 4 pins
[Us] Rated Supply Voltage 24 V DC SELV 12…33 V)
Current Consumption < 7 mA
Type Of Output Signal Analogue
Analogue Output Function 0...10 V, 3-wire
Quantity Per Set Set of 1
Type Of Packing Individual
Pressure Setting Range -14.50…0.00 psi (-1…0 bar)
Max Perm Accidental Pressure 43.51 psi (3 bar)
Destruction Pressure 72.52 psi (5 bar)
Materials In Contact Wth Fluid Stainless steel AISI 316L Ceramic Fluorocarbon FPM
Operating Position Any position
Protection Type Load short-circuit Reverse polarity
Electromagnetic Compatibility Susceptibility to electromagnetic fields EN/IEC 61000-4-3 10 V/m 80...1000 MHz Electrical fast transient/burst immunity test EN/IEC 61000-4-4 2 kV Radiated RF fields EN/IEC 61000-4-6 10 V 0.15...80 MHz Electrostatic discharge immunity test EN/IEC 61000-4-2 8 kV air, 4 kV contact 1.2/50 µs shock waves immunity test EN/IEC 61000-4-5 1 kV 42 Ohm Immunity to magnetic fields EN/IEC 61000-4-8 100 A/m 50 Hz
Uimp Rated Imp Wstd Voltage 0.5 kV
Response Time On Output <= 2 ms 10...90 % of full scale
Measurement Accuracy +/- 0.5 % of the measuring range
Resolution 0.1 % of the measuring range
Drift Of The Sensitivity +/- 0.02 % of measuring range/°K
Drift Of The Zero Point +/- 0.02 % of measuring range/°K
Long Term Stability +/- 0.25 % of the measuring range
Mechanical Durability 10000000 cycles
Product Weight 0.17 lb(US) (0.075 kg)
Diameter 1.02 in (26 mm)
Length 1.42 in (36 mm)
Standards NSF ANSI 61 EN/IEC 61326-2-3
Product Certifications CULus RCM CE EAC
Ambient Air Temp For Op -22…185 °F (-30…85 °C)
Ambient Air Temp For Storage -58…212 °F (-50…100 °C)
Vibration Resistance 20 gn 10…2000 Hz) EN/IEC 60068-2-6
Shock Resistance 100 gn 11 ms EN/IEC 60068-2-27
IP Degree Of Protection IP65 EN/IEC 60529 IP67 EN/IEC 60529 IP69K DIN 40050
Category 21561 - XMLK,XMLP PRESSURE TRANSMITTERS
Discount Schedule DS2
GTIN 03389119624992
Nbr. Of Units In Pkg. 1
Country Of Origin CH
EU RoHs Directive Pro-active compliance (Product out of EU RoHS legal scope)