| Part Number | LR9D01KITD09BD |
|---|---|
| Country of Origin | CN |
| Availability | N |
| Lead Time | 5 |
| UNSPSC | 39121521 |
| ECCN | EAR99 |
| Discount Schedule | I12 |
| Return Indicator | No |
| Depth | 3.74 inch |
| Height | 3.03 inch |
| Width | 1.77 inch |
| Weight | 1.06 pound |
| Range | TeSys |
|---|---|
| Product Or Component Type | Motor starter |
| Contactor Application | Motor control Resistive load |
| Utilisation Category | AC-4 AC-1 AC-3 |
| Poles Description | 3P |
| Power Pole Contact Composition | 3 NO |
| Ue Rated Operational Voltage | Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC |
| Ie Rated Operational Current | 9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit |
| Motor Power kW | 2.2 kW 220...230 V AC 50/60 Hz AC-3) 4 kW 380...400 V AC 50/60 Hz AC-3) 4 kW 415...440 V AC 50/60 Hz AC-3) 5.5 kW 500 V AC 50/60 Hz AC-3) 5.5 kW 660...690 V AC 50/60 Hz AC-3) 2.2 kW 400 V AC 50/60 Hz AC-4) |
| Motor Power Hp (Ul / Csa) | 1 hp 230/240 V AC 50/60 Hz 1 phase 2 hp 200/208 V AC 50/60 Hz 3 phase 2 hp 230/240 V AC 50/60 Hz 3 phase 5 hp 460/480 V AC 50/60 Hz 3 phase 7.5 hp 575/600 V AC 50/60 Hz 3 phase 0.33 hp 115 V AC 50/60 Hz 1 phase |
| Control Circuit Type | DC standard |
| Uc Control Circuit Voltage | 24 V DC |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 |
| Overvoltage Category | III |
| Ith Cnvtl Free Air Therm Crrt | 25 A 140 °F (60 °C) power circuit 10 A 140 °F (60 °C) signalling circuit |
| Irms Rated Making Capacity | 250 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 |
| Rated Breaking Capacity | 250 A 440 V power circuit IEC 60947 |
| Icw Rated Short-Time Wstd Crrt | 105 A 104 °F (40 °C) - 10 s power circuit 210 A 104 °F (40 °C) - 1 s power circuit 30 A 104 °F (40 °C) - 10 min power circuit 61 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit |
| Associated Fuse Rating | 10 A gG signalling circuit IEC 60947-5-1 25 A gG <= 690 V type 1 power circuit 20 A gG <= 690 V type 2 power circuit |
| Average Impedance | 2.5 mOhm - Ith 25 A 50 Hz power circuit |
| Ui Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL |
| Electrical Durability | 0.6 Mcycles 25 A AC-1 <= 440 V 2 Mcycles 9 A AC-3 <= 440 V |
| Power Dissipation Per Pole | 1.56 W AC-1 0.2 W AC-3 |
| Safety Cover | With |
| Mounting Support | Plate Rail |
| Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
| Product Certifications | LROS (Lloyds register of shipping) CSA UL GOST DNV CCC GL BV RINA |
| Connections - Terminals | Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Power circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end |
| Tightening Torque | Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 |
| Operating Time | 53.55...72.45 ms closing 16...24 ms opening |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical Durability | 30 Mcycles |
| Operating Rate | 3600 cyc/h 140 °F (60 °C) |
| Relay Application | Motor protection |
| Phase Failure Sensitivity | Phase difference > 40% 3 s IEC 60947-4-1 |
| Coil Technology | Built-in bidirectional peak limiting diode suppressor |
| Ctrl Circuit Voltage Limits | Drop-out 0.1...0.25 Uc DC 140 °F (60 °C)) Operational 0.7...1.25 Uc DC 140 °F (60 °C)) |
| Time Constant | 28 ms |
| Inrush Power In W | 5.4 W 68 °F (20 °C)) |
| Hold-In Power Consumption W | 5.4 W 68 °F (20 °C) |
| Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
| Signalling Circuit Frequency | 25...400 Hz |
| Minimum Switching Current | 5 mA signalling circuit |
| Minimum Switching Voltage | 17 V signalling circuit |
| Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
| Insulation Resistance | > 10 MOhm signalling circuit |
| Contact Compatibility | M4 |
| Motor Power Range | 1.1…2 kW 200…240 V 3 phase 2.2…3 kW 380…440 V 3 phase 4…6 kW 380…440 V 3 phase 4…6 kW 480…500 V 3 phase |
| Motor Starter Type | Direct on-line contactor |