Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
TeSys K reversing contactor – 3P – AC-3
LP2K0610ED
TeSys K reversing contactor – 3P – AC-3

LP2K0610ED is a compact 3-pole TeSys K reversing contactor from Schneider Electric for motor applications. Rated 6A AC-3 2.2kW@400V, it includes a 48V DC coil, 1NO auxiliary contact, a mechanical interlock and a pre-wired reversing circuit. LP2K0610ED is a 3-pole TeSys K reversing contactor from Schneider Electric for simple motor applications rated up to 2.2kW@400V. Very compact, DIN-rail compatible, it is assembled with a mechanical interlock and a pre-wired reversing circuit. It can be easily integrated into all control systems thanks to its 48V DC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Ready for connection to all control systems thanks to a 48V DC control voltage and 2NO built-in auxiliary contact. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).

Add to Quote Catalogue
Specifications
Part Number LP2K0610ED
Country of Origin FR
UPC 389110497052
UPC11 38911049705
EAN 3389110497052
Availability N
Lead Time 20
UNSPSC 39121529
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I12
Return Indicator No
Depth 2.24 inch
Height 2.28 inch
Width 3.54 inch
Weight 1.06 pound
Characteristics
Range TeSys
Product Name TeSys K
Product Or Component Type Reversing contactor
Device Short Name LP2K
Device Application Control
Contactor Application Motor control
Utilisation Category AC-4 AC-3
Device Presentation Preassembled with reversing power busbar
Poles Description 3P
Power Pole Contact Composition 3 NO
Ue Rated Operational Voltage Power circuit 690 V AC 50/60 Hz Signalling circuit <= 690 V AC 50/60 Hz
Ie Rated Operational Current 6 A<= 440 V AC AC-3 power circuit
Motor Power kW 1.5 kW 220...230 V AC 50/60 Hz 2.2 kW 380...415 V AC 50/60 Hz 3 kW 440 V AC 50/60 Hz 3 kW 480 V AC 50/60 Hz 3 kW 500...600 V AC 50/60 Hz 3 kW 660...690 V AC 50/60 Hz
Control Circuit Type DC standard
Uc Control Circuit Voltage 48 V DC
Auxiliary Contact Composition 1 NO
Uimp Rated Imp Wstd Voltage 8 kV
Overvoltage Category III
Ith Cnvtl Free Air Therm Crrt 20 A 122 °F (50 °C) power circuit 10 A 122 °F (50 °C) signalling circuit
Irms Rated Making Capacity 110 A AC power circuit NF C 63-110 110 A AC power circuit IEC 60947 110 A AC signalling circuit IEC 60947
Rated Breaking Capacity 110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947
Icw Rated Short-Time Wstd Crrt 90 A 122 °F (50 °C) - 1 s power circuit 85 A 122 °F (50 °C) - 5 s power circuit 80 A 122 °F (50 °C) - 10 s power circuit 60 A 122 °F (50 °C) - 30 s power circuit 45 A 122 °F (50 °C) - 1 min power circuit 40 A 122 °F (50 °C) - 3 min power circuit 80 A - 1 s signalling circuit 90 A - 500 ms signalling circuit 110 A - 100 ms signalling circuit 20 A 122 °F (50 °C) - >= 15 min power circuit
Associated Fuse Rating 25 A gG <= 440 V power circuit 25 A aM power circuit 10 A gG signalling circuit IEC 60947 10 A gG signalling circuit VDE 0660
Average Impedance 3 mOhm - Ith 20 A 50 Hz power circuit
Ui Rated Insulation Voltage Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14
Electrical Durability 1.3 Mcycles 6 A AC-3 <= 440 V
Interlocking Type Mechanical
Mounting Support Rail Plate
Standards NF C 63-110 VDE 0660 BS 5424 IEC 60947
Product Certifications CSA UL
Connections - Terminals screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end
Tightening Torque 11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm
Operating Time 30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability 5 Mcycles
Operating Rate 3600 cyc/h
Ctrl Circuit Voltage Limits Operational 0.8...1.15 Uc 122 °F (50 °C)) Drop-out 0.1...0.75 Uc 122 °F (50 °C))
Inrush Power In W 3 W 68 °F (20 °C))
Hold-In Power Consumption W 3 W 68 °F (20 °C)
Heat Dissipation 3 W
Auxiliary Contacts Type Instantaneous 1 NO
Minimum Switching Current 5 mA signalling circuit
Minimum Switching Voltage 17 V signalling circuit
Non Overlap Distance 0.02 in (0.5 mm)
Insulation Resistance > 10 MOhm signalling circuit
IP Degree Of Protection IP20 VDE 0106
Protective Treatment TC IEC 60068 TC DIN 50016
Ambient Air Temp For Op -13…122 °F (-25…50 °C)
Ambient Air Temp For Storage -58…176 °F (-50…80 °C)
Operating Altitude 6561.68 ft (2000 m) without derating
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews