| Part Number | LC8K0601F7 |
|---|---|
| Country of Origin | FR |
| UPC | 389110726046 |
| UPC11 | 38911072604 |
| EAN | 3389110726046 |
| Availability | N |
| Lead Time | 20 |
| UNSPSC | 39121529 |
| ECCN | EAR99 |
| HTs Code | 8536490065 |
| Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | I12 |
| Return Indicator | No |
| Depth | 2.24 inch |
| Height | 2.28 inch |
| Width | 3.54 inch |
| Weight | 1.06 pound |
| Range | TeSys |
|---|---|
| Product Name | TeSys K |
| Product Or Component Type | Reversing contactor |
| Device Short Name | LC8K |
| Device Application | Control |
| Contactor Application | Motor control |
| Utilisation Category | AC-4 AC-3 |
| Device Presentation | Preassembled with reversing power busbar |
| Poles Description | 3P |
| Power Pole Contact Composition | 3 NO |
| Ue Rated Operational Voltage | Power circuit 690 V AC 50/60 Hz Signalling circuit <= 690 V AC 50/60 Hz |
| Ie Rated Operational Current | 6 A<= 440 V AC AC-3 power circuit |
| Motor Power kW | 1.5 kW 220...230 V AC 50/60 Hz 2.2 kW 380...415 V AC 50/60 Hz 3 kW 440 V AC 50/60 Hz 3 kW 480 V AC 50/60 Hz 3 kW 500...600 V AC 50/60 Hz 3 kW 660...690 V AC 50/60 Hz |
| Control Circuit Type | AC 50/60 Hz silent |
| Uc Control Circuit Voltage | 110 V AC 50/60 Hz |
| Auxiliary Contact Composition | 1 NC |
| Uimp Rated Imp Wstd Voltage | 8 kV |
| Overvoltage Category | III |
| Ith Cnvtl Free Air Therm Crrt | 20 A 122 °F (50 °C) power circuit 10 A 122 °F (50 °C) signalling circuit |
| Irms Rated Making Capacity | 110 A AC power circuit NF C 63-110 110 A AC power circuit IEC 60947 110 A AC signalling circuit IEC 60947 |
| Rated Breaking Capacity | 110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947 |
| Icw Rated Short-Time Wstd Crrt | 90 A 122 °F (50 °C) - 1 s power circuit 85 A 122 °F (50 °C) - 5 s power circuit 80 A 122 °F (50 °C) - 10 s power circuit 60 A 122 °F (50 °C) - 30 s power circuit 45 A 122 °F (50 °C) - 1 min power circuit 40 A 122 °F (50 °C) - 3 min power circuit 80 A - 1 s signalling circuit 90 A - 500 ms signalling circuit 110 A - 100 ms signalling circuit 20 A 122 °F (50 °C) - >= 15 min power circuit |
| Associated Fuse Rating | 25 A gG <= 440 V power circuit 25 A aM power circuit 10 A gG signalling circuit IEC 60947 10 A gG signalling circuit VDE 0660 |
| Average Impedance | 3 mOhm - Ith 20 A 50 Hz power circuit |
| Ui Rated Insulation Voltage | Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14 |
| Electrical Durability | 1.3 Mcycles 6 A AC-3 <= 440 V |
| Interlocking Type | Mechanical |
| Mounting Support | Plate Rail |
| Standards | VDE 0660 NF C 63-110 IEC 60947 BS 5424 |
| Product Certifications | CSA UL |
| Connections - Terminals | screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end |
| Tightening Torque | 11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm |
| Operating Time | 30...40 ms coil energisation and NO closing 30 ms coil de-energisation and NO opening |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical Durability | 5 Mcycles |
| Operating Rate | 3600 cyc/h |
| Ctrl Circuit Voltage Limits | Operational 0.85...1.1 Uc 122 °F (50 °C)) Drop-out 0.1...0.75 Uc 122 °F (50 °C)) |
| Inrush Power In VA | 3 VA 68 °F (20 °C)) |
| Hold-In Power Consumption Va | 3 VA 68 °F (20 °C)) |
| Heat Dissipation | 3 W |
| Auxiliary Contacts Type | Instantaneous 1 NC |
| Signalling Circuit Frequency | <= 400 Hz |
| Minimum Switching Current | 5 mA signalling circuit |
| Minimum Switching Voltage | 17 V signalling circuit |
| Non Overlap Distance | 0.02 in (0.5 mm) |
| Insulation Resistance | > 10 MOhm signalling circuit |
| IP Degree Of Protection | IP20 VDE 0106 |
| Protective Treatment | TC IEC 60068 TC DIN 50016 |
| Ambient Air Temp For Op | -13…122 °F (-25…50 °C) |
| Ambient Air Temp For Storage | -58…176 °F (-50…80 °C) |