                  LR2K0316 is a TeSys LRK thermal overload relay from Schneider Electric to be used with a TeSys K contactors. It protects motors 4kW@400V thanks to a thermal range 8-11.5A, a tripping class 10A and phase unbalance protection. LR2K0316 is a TeSys LRK thermal overload relay from Schneider Electric for direct mounting on TeSys K contactors. With a thermal setting range 8-11.5A, a tripping class 10A and phase unbalance detection, it protects motors 4kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1K09 to form a compact starter. Light and compact, 45mm wide. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LA7K0064).
Add to Quote Catalogue| Part Number | LR2K0316 | 
|---|---|
| Country of Origin | CZ | 
| UPC | 785901913580 | 
| UPC11 | 78590191358 | 
| EAN | 3389110230581 | 
| Availability | S | 
| Lead Time | 3 | 
| UNSPSC | 39122330 | 
| ECCN | EAR99 | 
| HTs Code | 8536490075 | 
| Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov | 
| RoHS Compliant | Yes | 
| Discount Schedule | I12 | 
| Return Indicator | Yes | 
| Depth | 2.56 inch | 
| Height | 2.28 inch | 
| Width | 1.77 inch | 
| Weight | 0.32 pound | 
| Range | TeSys | 
|---|---|
| Product Name | TeSys LRK | 
| Product Or Component Type | Differential thermal overload relay | 
| Device Short Name | LR2K | 
| Relay Application | Motor protection | 
| Product Compatibility | LC7K LP1K LC1K LP4K | 
| Network Type | DC AC | 
| Thermal Overload Class | Class 10A IEC 60947-4-1 | 
| Thermal Protection Adj Range | 8…11.5 A | 
| Ui Rated Insulation Voltage | Power circuit 690 V BS 4941 Power circuit 690 V IEC 60947 Power circuit 750 V VDE 0110 group C Power circuit 600 V CSA C22.2 No 14 | 
| Network Frequency | <= 400 Hz | 
| Mounting Support | Under contactor Plate, with specific accessories Rail, with specific accessories | 
| Auxiliary Contact Composition | 1 NO + 1 NC | 
| Ith Cnvtl Free Air Therm Crrt | 6 A signalling circuit | 
| Ue Rated Operational Voltage | <= 690 V power circuit 690 V AC AC-15 signalling circuit 250 V DC DC-13 signalling circuit | 
| Associated Fuse Rating | 6 A gG signalling circuit VDE 0660 6 A gG signalling circuit IEC 60947 | 
| Uimp Rated Imp Wstd Voltage | 6 kV | 
| Power Dissipation Per Pole | 2 W | 
| Phase Failure Sensitivity | Yes IEC 60947-4-1 | 
| Local Signalling | Trip indicator Yellow) | 
| Control Type | Red push-button trip test function Blue push-button stop and manual reset selector switch manual or automatic reset | 
| Connections - Terminals | screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end | 
| Tightening Torque | 11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm | 
| Height | 2.28 in (58 mm) | 
| Width | 1.77 in (45 mm) | 
| Depth | 2.56 in (65 mm) | 
| Product Weight | 0.32 lb(US) (0.145 kg) | 
| Standards | IEC 60947 VDE 0660 BS 4941 NF C 63-650 | 
| Product Certifications | UL CSA | 
| Protective Treatment | TC IEC 60068 TC DIN 50016 | 
| IP Degree Of Protection | IP2x IEC 60529 | 
| Ambient Air Temp For Op | -4…131 °F (-20…55 °C) without derating IEC 60947 -22…140 °F (-30…60 °C) with derating IEC 60947 | 
| Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) | 
| Operating Altitude | 6561.68 ft (2000 m) without derating | 
| Fire Resistance | 1562 °F (850 °C) IEC 60695-2-1 | 
| Flame Retardance | V1 UL 94 Requirement 2 NF F 16-101 Requirement 2 NF F 16-102 | 
| Mechanical Robustness | Shocks NO contact10 Gn for 11 ms IEC 60068-2-27 Shocks NC contact10 Gn for 11 ms IEC 60068-2-27 Vibrations NO contact2 Gn, 5...300 Hz IEC 60068-2-6 Vibrations NC contact2 Gn, 5...300 Hz IEC 60068-2-6 | 
| Category | 22324 - CONTACTOR,K-LINE,OVERLOADS | 
| Discount Schedule | I12 | 
| GTIN | 00785901913580 | 
| Nbr. Of Units In Pkg. | 1 | 
| Country Of Origin | CZ | 
| Green Premium Status | Green Premium product | 
| REACh Free Of SVHC | Yes | 
| EU RoHs Directive | Compliant | 
| Mercury Free | Yes | 
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. | 
| Warranty | 18 months | 
Powered by 
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366