TeSys K contactor – 3P – AC-3
LC1K12015F7
TeSys K contactor – 3P – AC-3

TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 110V 50/60Hz AC coil, 1NC built-in auxiliary contact, connection by solder pins for printed circuit boards. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Add to Quote Catalogue
Specifications
Part Number LC1K12015F7
Country of Origin FR
UPC 389110789676
UPC11 38911078967
EAN 3389110789676
Availability N
Lead Time 30
HTs Code 8536490065
Discount Schedule I12
Return Indicator No
Characteristics
Range TeSys
Product Or Component Type Contactor
Product Name TeSys K
Device Short Name LC1K
Device Application Control
Contactor Application Motor control Resistive load
Utilisation Category AC-3 AC-4 AC-1
Poles Description 3P
Power Pole Contact Composition 3 NO
Ie Rated Operational Current 20 A 122 °F (50 °C)) <= 440 V AC AC-1 power circuit 12 A<= 440 V AC AC-3 power circuit 16 A 158 °F (70 °C)) 690 V AC AC-1 power circuit
Control Circuit Type AC 50/60 Hz
Uc Control Circuit Voltage 110 V AC 50/60 Hz
Motor Power kW 4 kW 480 V AC 50/60 Hz 4 kW 500...600 V AC 50/60 Hz 4 kW 660...690 V AC 50/60 Hz 3 kW 220...230 V AC 50/60 Hz 5.5 kW 380...415 V AC 50/60 Hz 5.5 kW 440 V AC 50/60 Hz
Auxiliary Contact Composition 1 NC
Overvoltage Category III
Ith Cnvtl Free Air Therm Crrt 20 A 122 °F (50 °C) power circuit 10 A 122 °F (50 °C) signalling circuit
Irms Rated Making Capacity 110 A AC signalling circuit IEC 60947 144 A AC power circuit NF C 63-110 144 A AC power circuit IEC 60947
Rated Breaking Capacity 110 A 440 V IEC 60947 80 A 500 V IEC 60947 70 A 660...690 V IEC 60947
Associated Fuse Rating 25 A gG <= 440 V power circuit 25 A aM power circuit 10 A gG signalling circuit IEC 60947 10 A gG signalling circuit VDE 0660
Average Impedance 3 mOhm - Ith 20 A 50 Hz power circuit
Insulation Resistance > 10 MOhm signalling circuit
Inrush Power In VA 30 VA 68 °F (20 °C))
Hold-In Power Consumption Va 4.5 VA 68 °F (20 °C))
Heat Dissipation 1.3 W
Ctrl Circuit Voltage Limits Operational 0.8...1.15 Uc 122 °F (50 °C)) Drop-out 0.2...0.75 Uc 122 °F (50 °C))
Operating Rate 3600 cyc/h
Auxiliary Contacts Type Instantaneous 1 NC
Signalling Circuit Frequency <= 400 Hz
Minimum Switching Current 5 mA signalling circuit
Minimum Switching Voltage 17 V signalling circuit
Operating Time 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Non Overlap Distance 0.02 in (0.5 mm)
Mechanical Robustness Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Product Certifications UL CSA
Protective Treatment TC IEC 60068 TC DIN 50016
Operating Altitude 6561.68 ft (2000 m) without derating
Flame Retardance V1 UL 94 Requirement 2 NF F 16-101 Requirement 2 NF F 16-102
Category 22326 - CTR,K-LINE,AC,OPEN,NONREV
Discount Schedule I12
GTIN 03389110789676
Nbr. Of Units In Pkg. 1
Country Of Origin FR
Warranty 18 months
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews