TeSys K contactor – 3P – AC-3
LC1K0910M7
TeSys K contactor – 3P – AC-3

LC1K0910M7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 220V 50/60Hz AC coil and 1NO auxiliary contact. LC1K0910M7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 4kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 220V 50/60Hz AC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).

Add to Quote Catalogue
Specifications
Part Number LC1K0910M7
Country of Origin ID
UPC 785901079927
UPC11 78590107992
EAN 3389110363876
Availability S
Lead Time 43
UNSPSC 39121529
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I12
Return Indicator Yes
Characteristics
Range TeSys
Product Or Component Type Contactor
Product Name TeSys K
Device Application Control
Contactor Application Motor control Resistive load
Utilisation Category AC-4 AC-3 AC-1
Poles Description 3P
Power Pole Contact Composition 3 NO
Ie Rated Operational Current 20 A 122 °F (50 °C)) <= 440 V AC AC-1 power circuit 9 A<= 440 V AC AC-3 power circuit 16 A 158 °F (70 °C)) 690 V AC AC-1 power circuit
Control Circuit Type AC 50/60 Hz
Uc Control Circuit Voltage 220...230 V AC 50/60 Hz
Motor Power kW 2.2 kW 220...230 V AC 50/60 Hz AC-3 4 kW 380...415 V AC 50/60 Hz AC-3 4 kW 440 V AC 50/60 Hz AC-3 4 kW 480 V AC 50/60 Hz AC-3 4 kW 500...600 V AC 50/60 Hz AC-3 4 kW 660...690 V AC 50/60 Hz AC-3 2.2 kW 400 V AC 50/60 Hz AC-4
Auxiliary Contact Composition 1 NO
Overvoltage Category III
Ith Cnvtl Free Air Therm Crrt 20 A 122 °F (50 °C) power circuit 10 A 122 °F (50 °C) signalling circuit
Irms Rated Making Capacity 110 A AC power circuit NF C 63-110 110 A AC power circuit IEC 60947 110 A AC signalling circuit IEC 60947
Rated Breaking Capacity 110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947
Associated Fuse Rating 25 A gG <= 440 V power circuit 25 A aM power circuit 10 A gG signalling circuit IEC 60947 10 A gG signalling circuit VDE 0660
Average Impedance 3 mOhm - Ith 20 A 50 Hz power circuit
Insulation Resistance > 10 MOhm signalling circuit
Inrush Power In VA 30 VA 68 °F (20 °C))
Hold-In Power Consumption Va 4.5 VA 68 °F (20 °C))
Heat Dissipation 1.3 W
Ctrl Circuit Voltage Limits Operational 0.8...1.15 Uc 122 °F (50 °C)) Drop-out 0.2...0.75 Uc 122 °F (50 °C))
Operating Rate 3600 cyc/h
Auxiliary Contacts Type Instantaneous 1 NO
Signalling Circuit Frequency <= 400 Hz
Minimum Switching Current 5 mA signalling circuit
Minimum Switching Voltage 17 V signalling circuit
Operating Time 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Non Overlap Distance 0.02 in (0.5 mm)
Mechanical Robustness Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Product Certifications CSA UL
Protective Treatment TC IEC 60068 TC DIN 50016
Operating Altitude 6561.68 ft (2000 m) without derating
Flame Retardance V1 UL 94 Requirement 2 NF F 16-101 Requirement 2 NF F 16-102
Category 22326 - CTR,K-LINE,AC,OPEN,NONREV
Discount Schedule I12
GTIN 00785901079927
Nbr. Of Units In Pkg. 1
Country Of Origin ID
Green Premium Status Green Premium product
REACh Free Of SVHC Yes
EU RoHs Directive Compliant
Toxic Heavy Metal Free Yes
Mercury Free Yes
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Warranty 18 months