LC1K0601E7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 6A AC-3 2.2kW@400V, it includes a 48V 50/60Hz AC coil and 1NC auxiliary contact. LC1K0601E7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 2.2kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 48V 50/60Hz AC coil and 1NC built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NC built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
Add to Quote CataloguePart Number | LC1K0601E7 |
---|---|
Country of Origin | FR |
UPC | 389110374735 |
UPC11 | 38911037473 |
EAN | 3389110374735 |
Availability | N |
Lead Time | 28 |
UNSPSC | 39121529 |
HTs Code | 8536490065 |
Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | No |
Depth | 2.24 inch |
Height | 2.28 inch |
Width | 1.77 inch |
Weight | 0.40 pound |
Range | TeSys |
---|---|
Product Or Component Type | Contactor |
Product Name | TeSys K |
Device Short Name | LC1K |
Device Application | Control |
Contactor Application | Motor control |
Utilisation Category | AC-3 AC-4 |
Poles Description | 3P |
Power Pole Contact Composition | 3 NO |
Ue Rated Operational Voltage | Power circuit 690 V AC 50/60 Hz Signalling circuit <= 690 V AC 50/60 Hz |
Ie Rated Operational Current | 6 A<= 440 V AC AC-3 power circuit |
Control Circuit Type | AC 50/60 Hz |
Uc Control Circuit Voltage | 48 V AC 50/60 Hz |
Motor Power kW | 1.5 kW 220...230 V AC 50/60 Hz AC-3 2.2 kW 380...415 V AC 50/60 Hz AC-3 3 kW 440 V AC 50/60 Hz AC-3 3 kW 480 V AC 50/60 Hz AC-3 3 kW 500...600 V AC 50/60 Hz AC-3 3 kW 660...690 V AC 50/60 Hz AC-3 1.5 kW 400 V AC 50/60 Hz AC-4 |
Auxiliary Contact Composition | 1 NC |
Uimp Rated Imp Wstd Voltage | 8 kV |
Overvoltage Category | III |
Ith Cnvtl Free Air Therm Crrt | 20 A 122 °F (50 °C) power circuit 10 A 122 °F (50 °C) signalling circuit |
Irms Rated Making Capacity | 110 A AC power circuit NF C 63-110 110 A AC power circuit IEC 60947 110 A AC signalling circuit IEC 60947 |
Rated Breaking Capacity | 110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947 |
Icw Rated Short-Time Wstd Crrt | 90 A 122 °F (50 °C) - 1 s power circuit 85 A 122 °F (50 °C) - 5 s power circuit 80 A 122 °F (50 °C) - 10 s power circuit 60 A 122 °F (50 °C) - 30 s power circuit 45 A 122 °F (50 °C) - 1 min power circuit 40 A 122 °F (50 °C) - 3 min power circuit 20 A 122 °F (50 °C) - >= 15 min power circuit 80 A - 1 s signalling circuit 90 A - 500 ms signalling circuit 110 A - 100 ms signalling circuit |
Associated Fuse Rating | 25 A gG <= 440 V power circuit 25 A aM power circuit 10 A gG signalling circuit IEC 60947 10 A gG signalling circuit VDE 0660 |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz power circuit |
Ui Rated Insulation Voltage | Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14 |
Insulation Resistance | > 10 MOhm signalling circuit |
Inrush Power In VA | 30 VA 68 °F (20 °C)) |
Hold-In Power Consumption Va | 4.5 VA 68 °F (20 °C)) |
Heat Dissipation | 1.3 W |
Ctrl Circuit Voltage Limits | Operational 0.8...1.15 Uc 122 °F (50 °C)) Drop-out 0.2...0.75 Uc 122 °F (50 °C)) |
Connections - Terminals | screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end |
Operating Rate | 3600 cyc/h |
Auxiliary Contacts Type | Instantaneous 1 NC |
Signalling Circuit Frequency | <= 400 Hz |
Minimum Switching Current | 5 mA signalling circuit |
Minimum Switching Voltage | 17 V signalling circuit |
Mounting Support | Plate Rail |
Tightening Torque | 11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm |
Operating Time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Non Overlap Distance | 0.02 in (0.5 mm) |
Mechanical Durability | 10 Mcycles |
Electrical Durability | 1.3 Mcycles 6 A AC-3 <= 440 V |
Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 |
Height | 2.28 in (58 mm) |
Width | 1.77 in (45 mm) |
Depth | 2.24 in (57 mm) |
Product Weight | 0.40 lb(US) (0.18 kg) |
Standards | BS 5424 IEC 60947 NF C 63-110 VDE 0660 |
Product Certifications | CSA UL |
IP Degree Of Protection | IP2x VDE 0106 |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366