| Part Number | LC7K1210M7 |
|---|---|
| Country of Origin | FR |
| UPC | 389110849943 |
| UPC11 | 38911084994 |
| EAN | 3389110849943 |
| Availability | N |
| Lead Time | 27 |
| UNSPSC | 39121529 |
| ECCN | EAR99 |
| HTs Code | 8536490065 |
| Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | I12 |
| Return Indicator | No |
| Depth | 2.24 inch |
| Weight | 0.50 pound |
| Range | TeSys |
|---|---|
| Product Or Component Type | Contactor |
| Product Name | TeSys K |
| Device Short Name | LC7K |
| Device Application | Control |
| Contactor Application | Motor control Resistive load |
| Utilisation Category | AC-3 AC-1 AC-4 |
| Poles Description | 3P |
| Power Pole Contact Composition | 3 NO |
| Ue Rated Operational Voltage | Power circuit 690 V AC 50/60 Hz Signalling circuit <= 690 V AC 50/60 Hz |
| Ie Rated Operational Current | 20 A 122 °F (50 °C)) <= 440 V AC AC-1 power circuit 12 A<= 440 V AC AC-3 power circuit 16 A 158 °F (70 °C)) 690 V AC AC-1 power circuit |
| Control Circuit Type | AC 50/60 Hz silent |
| Uc Control Circuit Voltage | 220...230 V AC 50/60 Hz |
| Motor Power kW | 4 kW 480 V AC 50/60 Hz AC-3 4 kW 500...600 V AC 50/60 Hz AC-3 4 kW 660...690 V AC 50/60 Hz AC-3 2.2 kW 400 V AC 50/60 Hz AC-4 3 kW 220...230 V AC 50/60 Hz AC-3 5.5 kW 380...415 V AC 50/60 Hz AC-3 5.5 kW 440 V AC 50/60 Hz AC-3 |
| Auxiliary Contact Composition | 1 NO |
| Uimp Rated Imp Wstd Voltage | 8 kV |
| Overvoltage Category | III |
| Ith Cnvtl Free Air Therm Crrt | 20 A 122 °F (50 °C) power circuit 10 A 122 °F (50 °C) signalling circuit |
| Irms Rated Making Capacity | 110 A AC signalling circuit IEC 60947 144 A AC power circuit NF C 63-110 144 A AC power circuit IEC 60947 |
| Rated Breaking Capacity | 110 A 440 V IEC 60947 80 A 500 V IEC 60947 70 A 660...690 V IEC 60947 |
| Icw Rated Short-Time Wstd Crrt | 115 A 122 °F (50 °C) - 1 s power circuit 105 A 122 °F (50 °C) - 5 s power circuit 100 A 122 °F (50 °C) - 10 s power circuit 75 A 122 °F (50 °C) - 30 s power circuit 55 A 122 °F (50 °C) - 1 min power circuit 50 A 122 °F (50 °C) - 3 min power circuit 80 A - 1 s signalling circuit 90 A - 500 ms signalling circuit 110 A - 100 ms signalling circuit 25 A 122 °F (50 °C) - >= 15 min power circuit |
| Associated Fuse Rating | 25 A gG <= 440 V power circuit 25 A aM power circuit 10 A gG signalling circuit IEC 60947 10 A gG signalling circuit VDE 0660 |
| Average Impedance | 3 mOhm - Ith 20 A 50 Hz power circuit |
| Ui Rated Insulation Voltage | Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14 |
| Insulation Resistance | > 10 MOhm signalling circuit |
| Inrush Power In VA | 3 VA 68 °F (20 °C)) |
| Hold-In Power Consumption Va | 3 VA 68 °F (20 °C)) |
| Heat Dissipation | 3 W |
| Ctrl Circuit Voltage Limits | Operational 0.85...1.1 Uc 122 °F (50 °C)) Drop-out 0.1...0.75 Uc 122 °F (50 °C)) |
| Connections - Terminals | screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end |
| Operating Rate | 3600 cyc/h |
| Auxiliary Contacts Type | Instantaneous 1 NO |
| Signalling Circuit Frequency | <= 400 Hz |
| Minimum Switching Current | 5 mA signalling circuit |
| Minimum Switching Voltage | 17 V signalling circuit |
| Mounting Support | Plate Rail |
| Tightening Torque | 11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm |
| Operating Time | 30...40 ms coil energisation and NO closing 30 ms coil de-energisation and NO opening |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Non Overlap Distance | 0.02 in (0.5 mm) |
| Mechanical Durability | 10 Mcycles |
| Electrical Durability | 0.3 Mcycles 20 A AC-1 <= 440 V 1.3 Mcycles 12 A AC-3 <= 440 V |
| Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 |
| Depth | 2.24 in (57 mm) |
| Product Weight | 0.50 lb(US) (0.225 kg) |
| Standards | BS 5424 IEC 60947 NF C 63-110 VDE 0660 |
| Product Certifications | CSA UL |
| IP Degree Of Protection | IP2x VDE 0106 |
| Protective Treatment | TC IEC 60068 TC DIN 50016 |
| Ambient Air Temp For Storage | -58…176 °F (-50…80 °C) |