TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NC fault signaling contact + 1NC instantaneous auxiliary contact. Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC. Fault signaling contact rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on left-hand side of the circuit breaker (1 block mounting maximum), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Add to Quote Catalogue| Part Number | GVAD0101 |
|---|---|
| Country of Origin | CZ |
| UPC | 785901212386 |
| UPC11 | 78590121238 |
| EAN | 3389110343526 |
| Availability | S |
| Lead Time | 33 |
| UNSPSC | 39121521 |
| HTs Code | 8536509065 |
| Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | I11 |
| Return Indicator | Yes |
| Depth | 2.60 inch |
| Height | 3.50 inch |
| Width | 0.37 inch |
| Weight | 0.12 pound |
| Range | TeSys |
|---|---|
| Device Short Name | GVAD |
| Product Or Component Type | Auxiliary contact block |
| Product Compatibility | GV3L GV2P GV2LE GV2RT GV2L GV2ME GV3P |
| Mounting Location | Left side |
| Auxiliary Contacts Operation | Fault signal 1 NC |
| Pole Contact Composition | 2 NC |
| Connections - Terminals | screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)solid screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)solid screw clamp terminals 1 0.00…0.00 in² (0.75…2.5 mm²)flexible without cable end screw clamp terminals 2 0.00…0.00 in² (0.75…2.5 mm²)flexible without cable end screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²)flexible with cable end screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²)flexible with cable end |
| Ui Rated Insulation Voltage | 690 V IEC 60947-1 300 V UL 508 300 V CSA C22.2 No 14 |
| Ue Rated Operational Voltage | 48...690 V AC 24...240 V DC |
| Ith Cnvtl Free Air Therm Crrt | 6 A 2.5 A fault signalling |
| Protection Type | GB2CB... circuit breaker GG fuse 10 A |
| Mechanical Durability | 100000 cycles |
| Minimum Switching Current | 5 mA |
| Minimum Switching Voltage | 17 V |
| Rated Opr Power In VA | 300 VA 48 V AC-15 100000 cycles 414 VA 690 V AC-15 100000 cycles 500 VA 110…127 V AC-15 100000 cycles 500 VA 500 V AC-15 100000 cycles 650 VA 440 V AC-15 100000 cycles 720 VA 230…240 V AC-15 100000 cycles 850 VA 380…415 V AC-15 100000 cycles 36 VA 24 V AC-14 1000 cycles 48 VA 48 V AC-14 1000 cycles 72 VA 110…127 V AC-14 1000 cycles |
| Rated Opr Power In W | 120 W 240 V DC-13 100000 cycles 140 W 110 V DC-13 100000 cycles 140 W 24 V DC-13 100000 cycles 180 W 60 V DC-13 100000 cycles 240 W 48 V DC-13 100000 cycles 15 W 48 V DC-13 1000 cycles 24 W 24 V DC-13 1000 cycles 9 W 60 V DC-13 1000 cycles |
| Tightening Torque | 12.39 lbf.in (1.4 N.m) screw clamp terminals |
| Height | 3.50 in (89 mm) |
| Width | 0.37 in (9.3 mm) |
| Depth | 2.60 in (66 mm) |
| Product Weight | 0.12 lb(US) (0.055 kg) |
| Environmental Characteristic | Normal environment |
| Category | 22367 - MANUAL STR PROTECTOR - GV2 |
| Discount Schedule | I11 |
| GTIN | 00785901212386 |
| Nbr. Of Units In Pkg. | 1 |
| Country Of Origin | CZ |
| Green Premium Status | Green Premium product |
| REACh Free Of SVHC | Yes |
| EU RoHs Directive | Compliant |
| Toxic Heavy Metal Free | Yes |
| Mercury Free | Yes |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Warranty | 18 months |