TeSys F contactor, 3 poles (3NO), 265A/1000V AC-3, for motor applications up to 132kW@400V. Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Add to Quote CataloguePart Number | LC1F265 |
---|---|
Country of Origin | CZ |
UPC | 785901132912 |
UPC11 | 78590113291 |
EAN | 3389110122459 |
Availability | S |
Lead Time | 3 |
UNSPSC | 39121529 |
ECCN | EAR99 |
HTs Code | 8536490065 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | Yes |
Depth | 8.39 inch |
Height | 7.99 inch |
Width | 7.93 inch |
Weight | 18.83 pound |
Range | TeSys |
---|---|
Product Name | TeSys F |
Product Or Component Type | Contactor |
Device Short Name | LC1F |
Contactor Application | Resistive load Motor control |
Utilisation Category | AC-3 AC-4 AC-1 |
Poles Description | 3P |
Power Pole Contact Composition | 3 NO |
Ue Rated Operational Voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
Ie Rated Operational Current | 350 A 104 °F (40 °C)) <= 440 V AC AC-1 265 A 131 °F (55 °C)) <= 440 V AC AC-3 |
Motor Power kW | 132 kW 380...400 V AC 50/60 Hz AC-3) 140 kW 415 V AC 50/60 Hz AC-3) 140 kW 440 V AC 50/60 Hz AC-3) 147 kW 1000 V AC 50/60 Hz AC-3) 160 kW 500 V AC 50/60 Hz AC-3) 75 kW 220...240 V AC 50/60 Hz AC-3) 160 kW 660...690 V AC 50/60 Hz AC-3) 51 kW 400 V AC 50/60 Hz AC-4) |
Uc Control Circuit Voltage | 24...1000 V AC 40...400 Hz with LX1/LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V with LXE coil |
Uimp Rated Imp Wstd Voltage | 8 kV |
Overvoltage Category | III |
Ith Cnvtl Free Air Therm Crrt | 350 A 104 °F (40 °C) |
Irms Rated Making Capacity | 2650 A AC IEC 60947-4-1 |
Rated Breaking Capacity | 2120 A IEC 60947-4-1 |
Icw Rated Short-Time Wstd Crrt | 2200 A 104 °F (40 °C) - 10 s 1230 A 104 °F (40 °C) - 30 s 950 A 104 °F (40 °C) - 1 min 620 A 104 °F (40 °C) - 3 min 480 A 104 °F (40 °C) - 10 min |
Associated Fuse Rating | 315 A aM <= 440 V 400 A gG <= 440 V |
Average Impedance | 0.3 mOhm - Ith 350 A 50 Hz |
Ui Rated Insulation Voltage | 1000 V IEC 60947-4-1 1500 V VDE 0110 group C |
Power Dissipation Per Pole | 37 W AC-1 21 W AC-3 |
Ctrl Circuit Voltage Limits | Operational 0.85...1.1 Uc AC 40...400 Hz Drop-out 0.35...0.55 Uc AC 40...400 Hz Operational 0.85...1.1 Uc DC Drop-out 0.15...0.2 Uc DC Operational 85...275 V AC 50/60 Hz Drop-out 0...60 V AC 50/60 Hz Operational 85...418 V DC Drop-out 0...45 V DC |
Heat Dissipation | 8 W 2.2…2.5 W |
Operating Time | 40...65 ms closing with LX1/LX9 coil 100...170 ms opening with LX1/LX9 coil 40...50 ms closing with LX4 coil 40...65 ms opening with LX4 coil 40...80 ms closing with LXE coil 6...54 ms opening with LXE coil |
Mounting Support | Plate |
Standards | IEC 60947-1 IEC 60947-4-1 JIS C8201-4-1 EN 60947-1 EN 60947-4-1 |
Product Certifications | ABS CB DNV RMRoS UL CSA RINA LROS (Lloyds register of shipping) BV |
Connections - Terminals | Power circuit bar 2 32 x 4 mm Power circuit lugs-ring terminals 1 0.37 in² (240 mm²) Power circuit connector 1 0.37 in² (240 mm²) Power circuit bolted connection Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) Control circuit screw clamp terminals 1.0 0.00…0.00 in² (0.2…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1.0 0.00…0.00 in² (0.25…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1.0 0.00…0.00 in² (0.2…2.5 mm²)solid without cable end |
Tightening Torque | Power circuit 309.78 lbf.in (35 N.m) Control circuit 10.62 lbf.in (1.2 N.m) Control circuit 5.31 lbf.in (0.6 N.m) |
Mechanical Durability | 10 Mcycles |
Inrush Power In VA | 600…700 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 655…803 VA (at 68 °F (20 °C))with LX4 coil 300…350 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 300…310 VA (at 68 °F (20 °C))with LXE coil |
Hold-In Power Consumption Va | 8…10 VA 3.68…4.53 VA 4.5…7.0 VA 2.5…4.0 VA |
Operating Rate | 2400 cyc/h 131 °F (55 °C) |
Compatibility Code | LC1F |
IP Degree Of Protection | IP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106 |
Protective Treatment | TH |
Ambient Air Temp For Op | 23…131 °F (-5…55 °C) |
Ambient Air Temp For Storage | -76…176 °F (-60…80 °C) |
Ambient Air Temp Around Device | -40…158 °F (-40…70 °C) |
Mechanical Robustness | Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed5 Gn, 5...300 Hz Shocks contactor open6 Gn for 1/2 sine wave (11 ms) Shocks contactor closed15 Gn for 1/2 sine wave (11 ms) |
Height | 7.99 in (203 mm) |
Width | 7.93 in (201.5 mm) |
Depth | 8.39 in (213 mm) |
Product Weight | 18.83 lb(US) (8.54 kg) |
Category | 22336 - CTR,F-LINE,AC,OPEN,NONREV |
Discount Schedule | I12 |
GTIN | 00785901132912 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | CZ |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366