TeSys D – star delta starter – 3 x 3P (3 NO) – 80 A – 230 V AC coil
LC3D80P7A64
TeSys D – star delta starter – 3 x 3P (3 NO) – 80 A – 230 V AC coil
Specifications
Part Number LC3D80P7A64
Country of Origin FR
UPC 389110961393
UPC11 38911096139
EAN 3389110961393
Availability N
Lead Time 24
UNSPSC 39121529
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule CP10
Return Indicator No
Depth 7.20 inch
Height 5.63 inch
Width 12.24 inch
Weight 11.90 pound
Characteristics
Range TeSys
Product Name TeSys D
Product Or Component Type Star delta starter
Device Short Name LC3D
Contactor Application Motor control
Utilisation Category AC-3
Device Presentation Pre-wired
Poles Description 3 x 3P
Power Pole Contact Composition 3 x 3 NO
Ue Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz
Ie Rated Operational Current 80 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
Motor Power kW 37 kW 220/230 V AC 50/60 Hz 75 kW 380/400 V AC 50/60 Hz 75 kW 415 V AC 50/60 Hz 75 kW 440 V AC 50/60 Hz
Control Circuit Type AC 50/60 Hz
Uc Control Circuit Voltage 230 V AC 50/60 Hz
Auxiliary Contact Composition 1 NC KM2 line contactor 1 NO KM3 delta contactor
Uimp Rated Imp Wstd Voltage 8 kV IEC 60947
Overvoltage Category III
Ui Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 Signalling circuit 1000 V IEC 60947-1
Electrical Durability 10 Mcycles 80 A AC-3 <= 440 V
Interlocking Type Mechanical
Mounting Support Plate
Standards EN 60947-4-1 IEC 60947-4-1 EN 60947-5-1 UL 508 IEC 60947-5-1 CSA C22.2 No 14
Product Certifications RINA GL UL LROS (Lloyds register of shipping) DNV CCC GOST BV CSA
Connections - Terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end Power circuit screw clamp terminals 1 0.01…0.08 in² (4…50 mm²) flexible without cable end Power circuit screw clamp terminals 2 0.01…0.04 in² (4…25 mm²) flexible without cable end Power circuit screw clamp terminals 1 0.01…0.08 in² (4…50 mm²) flexible with cable end Power circuit screw clamp terminals 2 0.01…0.02 in² (4…16 mm²) flexible with cable end Power circuit screw clamp terminals 1 0.01…0.08 in² (4…50 mm²) solid without cable end Power circuit screw clamp terminals 2 0.01…0.04 in² (4…25 mm²) solid without cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) flexible with cable end
Tightening Torque Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) screw clamp terminals flat Ø 6...8 mm
Mechanical Durability 4 Mcycles
Operating Rate 30 cyc/h 140 °F (60 °C)
Starting Time 30 s
Coil Technology Without built-in suppressor module
Ctrl Circuit Voltage Limits Drop-out 0.3...0.6 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.8...1.1 Uc 50 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 60 Hz 131 °F (55 °C))
Inrush Power In VA 140 VA 60 Hz 0.75 68 °F (20 °C)) 160 VA 50 Hz 0.75 68 °F (20 °C))
Hold-In Power Consumption Va 13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C))
Heat Dissipation 4…5 W 50/60 Hz
Auxiliary Contacts Type Mechanically linked IEC 60947-5-1 3 x 1 NO + 1 NC Mirror contact IEC 60947-4-1 3 x 1 NC
Signalling Circuit Frequency 25...400 Hz
Minimum Switching Current 5 mA signalling circuit
Minimum Switching Voltage 17 V signalling circuit
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Width 12.24 in (311 mm)
Height 5.63 in (143 mm)
Depth 7.20 in (183 mm)
Product Weight 11.90 lb(US) (5.4 kg)
Insulation Resistance > 10 MOhm signalling circuit
IP Degree Of Protection IP20 front face IEC 60529
Protective Treatment TH IEC 60068-2-30
Pollution Degree 3
Ambient Air Temp For Storage -76…176 °F (-60…80 °C)
Ambient Air Temp For Op -40…140 °F (-40…60 °C) 140…158 °F (60…70 °C) with derating
Operating Altitude 9842.52 ft (3000 m)
Fire Resistance 1562 °F (850 °C) IEC 60695-2-1
Documents