Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
TeSys D – star delta starter – 3 x 3P (3 NO) – 18 A – 110 V AC coil
LC3D18AF7
TeSys D – star delta starter – 3 x 3P (3 NO) – 18 A – 110 V AC coil
Specifications
Part Number LC3D18AF7
Country of Origin FR
UPC 785901756811
UPC11 78590175681
EAN 3389110546101
Availability N
Lead Time 25
UNSPSC 39121529
ECCN EAR99
HTs Code 8536504000
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I12
Return Indicator No
Depth 5.63 inch
Height 4.88 inch
Width 5.67 inch
Weight 3.81 pound
Characteristics
Range TeSys
Product Name TeSys D
Product Or Component Type Star delta starter
Device Short Name LC3D
Contactor Application Motor control
Utilisation Category AC-3
Device Presentation Pre-wired
Poles Description 3 x 3P
Power Pole Contact Composition 3 x 3 NO
Ue Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz
Ie Rated Operational Current 18 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
Motor Power kW 11 kW 220/230 V AC 50/60 Hz 22 kW 415 V AC 50/60 Hz 22 kW 440 V AC 50/60 Hz 18.5 kW 380/400 V AC 50/60 Hz
Control Circuit Type AC 50/60 Hz
Uc Control Circuit Voltage 110 V AC 50/60 Hz
Auxiliary Contact Composition 1 NC KM1 star contactor
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947
Overvoltage Category III
Ui Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
Electrical Durability 1.65 Mcycles 18 A AC-3 <= 440 V
Safety Cover Protective cover
Interlocking Type Mechanical
Mounting Support Plate
Standards EN 60947-5-1 EN 60947-4-1 UL 508 IEC 60947-4-1 IEC 60947-5-1 CSA C22.2 No 14
Product Certifications RINA DNV GOST BV LROS (Lloyds register of shipping) GL CSA UL CCC
Connections - Terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end Power circuit screw clamp terminals 1 0.00…0.01 in² (1.5…6 mm²) flexible without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²) flexible without cable end Power circuit screw clamp terminals 1 0.00…0.01 in² (1…6 mm²) flexible with cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible with cable end Power circuit screw clamp terminals 1 0.00…0.01 in² (1.5…6 mm²) solid without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²) solid without cable end
Tightening Torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Operating Rate 30 cyc/h 140 °F (60 °C)
Starting Time 30 s
Coil Technology Without built-in suppressor module
Ctrl Circuit Voltage Limits Drop-out 0.3...0.6 Uc 50/60 Hz 140 °F (60 °C)) Operational 0.8...1.1 Uc 50 Hz 140 °F (60 °C)) Operational 0.85...1.1 Uc 60 Hz 140 °F (60 °C))
Inrush Power In VA 70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C))
Hold-In Power Consumption Va 7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C))
Heat Dissipation 2…3 W 50/60 Hz
Auxiliary Contacts Type Mechanically linked IEC 60947-5-1 3 x 1 NO + 1 NC Mirror contact IEC 60947-4-1 3 x 1 NC
Signalling Circuit Frequency 25...400 Hz
Minimum Switching Current 5 mA signalling circuit
Minimum Switching Voltage 17 V signalling circuit
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Width 5.67 in (144 mm)
Height 4.88 in (124 mm)
Depth 5.63 in (143 mm)
Product Weight 3.81 lb(US) (1.73 kg)
Insulation Resistance > 10 MOhm signalling circuit
IP Degree Of Protection IP20 front face IEC 60529
Protective Treatment TH IEC 60068-2-30
Pollution Degree 3
Ambient Air Temp For Storage -76…176 °F (-60…80 °C)
Ambient Air Temp For Op -40…158 °F (-40…70 °C) at Uc
Operating Altitude 9842.52 ft (3000 m) without derating
Fire Resistance 1562 °F (850 °C) IEC 60695-2-1
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews