Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
TeSys D – star delta starter – 3 x 3P (3 NO) – 150 A – 220 V AC coil
LC3D150M7
TeSys D – star delta starter – 3 x 3P (3 NO) – 150 A – 220 V AC coil
Specifications
Part Number LC3D150M7
Country of Origin FR
UPC 389110208047
UPC11 38911020804
EAN 3389110208047
Availability N
Lead Time 20
UNSPSC 39121529
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule CP10
Return Indicator No
Depth 8.07 inch
Height 21.85 inch
Width 17.72 inch
Weight 26.68 pound
Characteristics
Range TeSys
Product Name TeSys D
Product Or Component Type Star delta starter
Device Short Name LC3D
Contactor Application Motor control
Utilisation Category AC-3
Device Presentation Pre-wired
Poles Description 3 x 3P
Power Pole Contact Composition 3 x 3 NO
Ue Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz
Ie Rated Operational Current 150 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
Motor Power kW 132 kW 380/400 V AC 50/60 Hz 132 kW 415 V AC 50/60 Hz 147 kW 440 V AC 50/60 Hz 75 kW 220/230 V AC 50/60 Hz
Control Circuit Type AC 50/60 Hz
Uc Control Circuit Voltage 220 V AC 50/60 Hz
Auxiliary Contact Composition 1 NC KM1 star contactor 1 NC KM2 line contactor 1 NO KM3 delta contactor
Uimp Rated Imp Wstd Voltage 8 kV IEC 60947
Overvoltage Category III
Ui Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 Signalling circuit 1000 V IEC 60947-1
Electrical Durability 0.85 Mcycles 150 A AC-3 <= 440 V
Mounting Support Plate
Standards CSA C22.2 No 14 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 EN 60947-4-1 UL 508
Product Certifications CCC RINA LROS (Lloyds register of shipping) GL CSA DNV UL GOST BV
Connections - Terminals Power circuit connector 1 0.02…0.19 in² (10…120 mm²) flexible without cable end Power circuit connector 2 0.02…0.08 in² (10…50 mm²) flexible without cable end Power circuit connector 1 0.02…0.19 in² (10…120 mm²) flexible with cable end Power circuit connector 2 0.02…0.08 in² (10…50 mm²) flexible with cable end Power circuit connector 1 0.02…0.19 in² (10…120 mm²) solid without cable end Power circuit connector 2 0.02…0.08 in² (10…50 mm²) solid without cable end Control circuit connector 1 0.00…0.00 in² (1…2.5 mm²) flexible without cable end Control circuit connector 2 0.00…0.00 in² (1…2.5 mm²) flexible without cable end Control circuit connector 1 0.00…0.00 in² (1…2.5 mm²) flexible with cable end Control circuit connector 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end Control circuit connector 1 0.00…0.00 in² (1…2.5 mm²) solid without cable end Control circuit connector 2 0.00…0.00 in² (1…2.5 mm²) solid without cable end
Tightening Torque Power circuit 106.21 lbf.in (12 N.m) connector flat Ø 6...8 mm Control circuit 10.62 lbf.in (1.2 N.m) connector flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) connector Philips No 2
Mechanical Durability 8 Mcycles
Operating Rate 30 cyc/h 140 °F (60 °C)
Starting Time 30 s
Coil Technology Without built-in suppressor module
Ctrl Circuit Voltage Limits Drop-out 0.3...0.5 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.8...1.15 Uc 50/60 Hz 131 °F (55 °C))
Inrush Power In VA 280…350 VA 60 Hz 0.9 68 °F (20 °C)) 280…350 VA 50 Hz 0.9 68 °F (20 °C))
Hold-In Power Consumption Va 2…18 VA 60 Hz 0.9 68 °F (20 °C)) 2…18 VA 50 Hz 0.9 68 °F (20 °C))
Heat Dissipation 3…4.5 W 50/60 Hz
Auxiliary Contacts Type Mechanically linked IEC 60947-5-1 3 x 1 NO + 1 NC Mirror contact IEC 60947-4-1 3 x 1 NC
Signalling Circuit Frequency 25...400 Hz
Minimum Switching Current 5 mA signalling circuit
Minimum Switching Voltage 17 V signalling circuit
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Width 17.72 in (450 mm)
Height 21.85 in (555 mm)
Depth 8.07 in (205 mm)
Product Weight 26.68 lb(US) (12.1 kg)
Insulation Resistance > 10 MOhm signalling circuit
IP Degree Of Protection IP2x front face IEC 60529
Protective Treatment TH IEC 60068-2-30
Pollution Degree 3
Ambient Air Temp For Storage -76…176 °F (-60…80 °C)
Ambient Air Temp For Op -40…158 °F (-40…70 °C) at Uc
Operating Altitude 9842.52 ft (3000 m) without derating
Fire Resistance 1562 °F (850 °C) IEC 60695-2-1
Flame Retardance V1 UL 94
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews