| Part Number | LC1D18F7TQ |
|---|---|
| Country of Origin | FR |
| UPC | 785901213222 |
| UPC11 | 78590121322 |
| EAN | 3389110123814 |
| Availability | N |
| Lead Time | 48 |
| UNSPSC | 39121529 |
| ECCN | EAR99 |
| HTs Code | 8536490065 |
| Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | I12 |
| Return Indicator | Yes |
| Depth | 3.39 inch |
| Height | 3.03 inch |
| Width | 1.77 inch |
| Weight | 7.28 pound |
| Range Of Product | TeSys D |
|---|---|
| Range | TeSys |
| Product Or Component Type | Contactor |
| Device Short Name | LC1D |
| Contactor Application | Resistive load Motor control |
| Utilisation Category | AC-1 AC-3 |
| Control Circuit Type | AC 50/60 Hz |
| Poles Description | 3P |
| Pole Contact Composition | 3 NO |
| Ie Rated Operational Current | 32 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 18 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit |
| Motor Power kW | 10 kW 500 V AC 50/60 Hz 10 kW 660...690 V AC 50/60 Hz 4 kW 220...230 V AC 50/60 Hz 7.5 kW 380...400 V AC 50/60 Hz 9 kW 415...440 V AC 50/60 Hz |
| Motor Power Hp | 1 hp 115 V AC 50/60 Hz 1P UL 1 hp 115 V AC 50/60 Hz 1P CSA 10 hp 460/480 V AC 50/60 Hz 3P CSA 10 hp 460/480 V AC 50/60 Hz 3P UL 15 hp 575/600 V AC 50/60 Hz 3P CSA 15 hp 575/600 V AC 50/60 Hz 3P UL 5 hp 200/208 V AC 50/60 Hz 3P CSA 5 hp 200/208 V AC 50/60 Hz 3P UL 3 hp 230...240 V AC 50/60 Hz 1P CSA 3 hp 230...240 V AC 50/60 Hz 1P UL 5 hp 230...240 V AC 50/60 Hz 3P CSA 5 hp 230...240 V AC 50/60 Hz 3P UL |
| [Uc] Control Circuit Voltage | 110 V AC 50/60 Hz |
| Connections - Terminals | Control circuit screw clamp terminal 1 x 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminal 2 x 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminal 2 x 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit spring terminal 1 x 0.00 in² (2.5 mm²)flexible without cable end Control circuit spring terminal 2 x 0.00 in² (2.5 mm²)flexible without cable end Control circuit screw clamp terminal 1 x 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminal 1 x 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminal 2 x 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Power circuit ring lugs 0.31 in (8 mm)) Control circuit ring lugs 0.31 in (8 mm)) Power circuit screw clamp terminal 1 x 0.00…0.01 in² (1…6 mm²)flexible with cable end Power circuit screw clamp terminal 1 x 0.00…0.01 in² (1.5…6 mm²)flexible without cable end Power circuit screw clamp terminal 1 x 0.00…0.01 in² (1.5…6 mm²)solid without cable end Power circuit screw clamp terminal 2 x 0.00…0.01 in² (1.5…6 mm²)solid without cable end Power circuit spring terminal 1 x 0.01 in² (4 mm²)flexible without cable end Power circuit screw clamp terminal 2 x 0.00…0.01 in² (1.5…6 mm²)flexible without cable end Power circuit screw clamp terminal 2 x 0.00…0.01 in² (1…4 mm²)flexible with cable end Power circuit spring terminal 2 x 0.01 in² (4 mm²) |
| Quantity Per Set | Set of 10 |
| Coil Technology | Without built-in bidirectional peak limiting diode suppressor |
| Protective Cover | With |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Ctrl Circuit Voltage Limits | Drop-out 0.3...0.6 Uc 50/60 Hz 140 °F (60 °C)) Operational 0.8...1.1 Uc 50 Hz 140 °F (60 °C)) Operational 0.85...1.1 Uc 60 Hz 140 °F (60 °C)) |
| Ui Rated Insulation Voltage | Control circuit 600 V CSA Control circuit 600 V UL Power circuit 600 V CSA Power circuit 600 V UL Control circuit 690 V IEC 60947-4-1 Power circuit 690 V IEC 60947-4-1 |
| Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 |
| Overvoltage Category | III |
| Mounting Support | Rail Plate |
| Flame Retardance | V1 UL 94 |
| Tightening Torque | Control circuit 15.05 lbf.in (1.7 N.m) flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) Philips No 2 Power circuit 15.05 lbf.in (1.7 N.m) flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) Philips No 2 |
| Ue Rated Operational Voltage | Power circuit <= 690 V AC 25...400 Hz |
| Ith Cnvtl Free Air Therm Crrt | 10 A 140 °F (60 °C) control circuit 32 A 140 °F (60 °C) power circuit |
| Irms Rated Making Capacity | 140 A AC control circuit IEC 60947-5-1 300 A 440 V power circuit IEC 60947 |
| Rated Breaking Capacity | 300 kA 440 V power circuit IEC 60947 |
| Associated Fuse Rating | 10 A gG control circuit IEC 60947-5-1 35 A <= 690 V type 2 power circuit 50 A <= 690 V type 1 power circuit |
| Average Impedance | 2.5 mOhm - Ith 32 A 50 Hz power circuit |
| Power Dissipation Per Pole | 0.8 W AC-3 2.5 W AC-1 |
| Inrush Power In VA | 70 VA 0.75 68 °F (20 °C)) |
| Hold-In Power Consumption Va | 7 VA 50/60 Hz 0.3 68 °F (20 °C)) |
| Operating Time | 4...19 ms opening 12...22 ms closing |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical Durability | 15000000 cycles |
| Operating Rate | 3600 cyc/h 140 °F (60 °C) |
| Minimum Switching Current | 5 mA control circuit |
| Minimum Switching Voltage | 17 V control circuit |
| Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts |
| Insulation Resistance | > 10 MOhm control circuit |
| Height | 3.03 in (77 mm) |
| Width | 1.77 in (45 mm) |
| Depth | 3.39 in (86 mm) |
| Product Weight | 7.28 lb(US) (3.3 kg) |
| Standards | EN/IEC 60947-4-1 CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508 |
| Product Certifications | CCC GOST GL UL LROS (Lloyds register of shipping) DNV BV RINA CSA |
| IP Degree Of Protection | IP2x IEC 60529 IP2x VDE 0106 |
| Ambient Air Temp For Op | 23…140 °F (-5…60 °C) |