| Part Number | LC1D326BLS207 |
|---|---|
| Country of Origin | FR |
| UPC | 785901276845 |
| UPC11 | 78590127684 |
| EAN | 3389118234604 |
| Availability | N |
| Lead Time | 20 |
| UNSPSC | 39121529 |
| ECCN | EAR99 |
| HTs Code | 8536490065 |
| Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | I12 |
| Return Indicator | No |
| Depth | 3.98 inch |
| Height | 3.35 inch |
| Width | 1.77 inch |
| Weight | 0.83 pound |
| Range | TeSys |
|---|---|
| Product Name | TeSys D |
| Product Or Component Type | Contactor |
| Device Short Name | LC1D |
| Contactor Application | Resistive load Motor control |
| Utilisation Category | AC-3 AC-1 |
| Poles Description | 3P |
| Power Pole Contact Composition | 3 NO |
| Ue Rated Operational Voltage | Power circuit <= 690 V AC 25...400 Hz |
| Ie Rated Operational Current | 32 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 50 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit |
| Motor Power kW | 7.5 kW 220/230 V AC 50 Hz AC-3) 15 kW 380/400 V AC 50 Hz AC-3) 15 kW 415 V AC 50 Hz AC-3) 15 kW 440 V AC 50 Hz AC-3) 18.5 kW 500 V AC 50 Hz AC-3) 18.5 kW 660/690 V AC 50 Hz AC-3) |
| Uc Control Circuit Voltage | 24 V DC |
| Coil Type | Low consumption |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 |
| Overvoltage Category | III |
| Ith Cnvtl Free Air Therm Crrt | 10 A 140 °F (60 °C) signalling circuit 50 A 140 °F (60 °C) power circuit |
| Irms Rated Making Capacity | 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 550 A 440 V power circuit IEC 60947 |
| Rated Breaking Capacity | 550 A 440 V power circuit IEC 60947 |
| Icw Rated Short-Time Wstd Crrt | 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit 260 A 104 °F (40 °C) - 10 s power circuit 430 A 104 °F (40 °C) - 1 s power circuit 60 A 104 °F (40 °C) - 10 min power circuit 138 A 104 °F (40 °C) - 1 min power circuit |
| Associated Fuse Rating | 10 A gG signalling circuit IEC 60947-5-1 63 A gG <= 690 V type 1 power circuit 63 A gG <= 690 V type 2 power circuit |
| Average Impedance | 2 mOhm - Ith 50 A 50 Hz power circuit |
| Ui Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 |
| Electrical Durability | 1.65 Mcycles 32 A AC-3 <= 440 V 1.4 Mcycles 50 A AC-1 <= 440 V |
| Power Dissipation Per Pole | 2 W AC-3 5 W AC-1 |
| Front Cover | With |
| Mounting Support | Rail Plate |
| Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 EN 45545 R22 HL3 EN 45545 R26 HL3 DIN 5510-2 |
| Product Certifications | IEC CCC EAC UA TR |
| Connections - Terminals | Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.47 in (12 mm)) |
| Tightening Torque | Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 22.13 lbf.in (2.5 N.m) lugs-ring terminals Philips No 2 M4 Power circuit 22.13 lbf.in (2.5 N.m) lugs-ring terminals flat Ø 6 mm M4 |
| Operating Time | 55...75 ms closing 16...32 ms opening |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical Durability | 30 Mcycles |
| Operating Rate | 3600 cyc/h 140 °F (60 °C) |
| Coil Technology | With integral suppression device |
| Ctrl Circuit Voltage Limits | 0.1...0.25 Uc -40…158 °F (-40…70 °C) drop-out DC 0.7...1.25 Uc -40…158 °F (-40…70 °C) operational DC |
| Time Constant | 37 ms |
| Inrush Power In W | 4 W 68 °F (20 °C) |
| Hold-In Power Consumption W | 4 W 68 °F (20 °C) |
| Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
| Signalling Circuit Frequency | 25...400 Hz |
| Minimum Switching Current | 5 mA signalling circuit |
| Minimum Switching Voltage | 17 V signalling circuit |
| Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
| Insulation Resistance | > 10 MOhm signalling circuit |
| Contact Compatibility | M5 |
| Compatibility Code | LC1D |
| IP Degree Of Protection | IP20 front face IEC 60529 |
| Protective Treatment | TH IEC 60068-2-30 |