| Part Number | LC1DT40G7 | 
|---|---|
| Country of Origin | ID | 
| UPC | 785901503187 | 
| UPC11 | 78590150318 | 
| EAN | 3389110339567 | 
| Availability | S | 
| Lead Time | 3 | 
| UNSPSC | 39121529 | 
| ECCN | EAR99 | 
| HTs Code | 8536490065 | 
| Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov | 
| RoHS Compliant | Yes | 
| Discount Schedule | I12 | 
| Return Indicator | Yes | 
| Depth | 3.90 inch | 
| Height | 3.58 inch | 
| Width | 1.77 inch | 
| Weight | 0.94 pound | 
| Range | TeSys | 
|---|---|
| Product Name | TeSys D | 
| Product Or Component Type | Contactor | 
| Device Short Name | LC1D | 
| Contactor Application | Resistive load | 
| Utilisation Category | AC-1 | 
| Poles Description | 4P | 
| Power Pole Contact Composition | 4 NO | 
| Ue Rated Operational Voltage | Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC | 
| Ie Rated Operational Current | 40 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit | 
| Control Circuit Type | AC 50/60 Hz | 
| Uc Control Circuit Voltage | 120 V AC 50/60 Hz | 
| Auxiliary Contact Composition | 1 NO + 1 NC | 
| Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 | 
| Overvoltage Category | III | 
| Ith Cnvtl Free Air Therm Crrt | 10 A 140 °F (60 °C) signalling circuit 40 A 140 °F (60 °C) power circuit | 
| Irms Rated Making Capacity | 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 450 A 440 V power circuit IEC 60947 | 
| Rated Breaking Capacity | 450 A 440 V power circuit IEC 60947 | 
| Icw Rated Short-Time Wstd Crrt | 50 A 104 °F (40 °C) - 10 min power circuit 120 A 104 °F (40 °C) - 1 min power circuit 240 A 104 °F (40 °C) - 10 s power circuit 380 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit | 
| Associated Fuse Rating | 10 A gG signalling circuit IEC 60947-5-1 63 A gG <= 690 V type 1 power circuit 40 A gG <= 690 V type 2 power circuit | 
| Average Impedance | 2 mOhm - Ith 40 A 50 Hz power circuit | 
| Ui Rated Insulation Voltage | Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1 | 
| Electrical Durability | 1.4 Mcycles 40 A AC-1 <= 440 V | 
| Power Dissipation Per Pole | 3.2 W AC-1 | 
| Front Cover | With | 
| Mounting Support | Rail Plate | 
| Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | 
| Product Certifications | DNV GOST BV GL CSA UL LROS (Lloyds register of shipping) RINA CCC | 
| Connections - Terminals | Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end Power circuit connector 1 0.00…0.02 in² (2.5…10 mm²)flexible without cable end Power circuit connector 2 0.00…0.02 in² (2.5…10 mm²)flexible without cable end Power circuit connector 1 0.00…0.02 in² (2.5…10 mm²)flexible with cable end Power circuit connector 2 0.00…0.02 in² (2.5…10 mm²)flexible with cable end Power circuit connector 1 0.00…0.02 in² (2.5…16 mm²)solid without cable end Power circuit connector 2 0.00…0.02 in² (2.5…16 mm²)solid without cable end | 
| Tightening Torque | Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 15.05 lbf.in (1.7 N.m) connector flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) connector Philips No 2 | 
| Operating Time | 4...19 ms opening 12...22 ms closing | 
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 | 
| Mechanical Durability | 15 Mcycles | 
| Operating Rate | 3600 cyc/h 140 °F (60 °C) | 
| Coil Technology | Without built-in suppressor module | 
| Ctrl Circuit Voltage Limits | 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz | 
| Inrush Power In VA | 70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C)) | 
| Hold-In Power Consumption Va | 7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C)) | 
| Heat Dissipation | 2…3 W 50/60 Hz | 
| Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 | 
| Signalling Circuit Frequency | 25...400 Hz | 
| Minimum Switching Current | 5 mA signalling circuit | 
| Minimum Switching Voltage | 17 V signalling circuit | 
| Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | 
| Insulation Resistance | > 10 MOhm signalling circuit | 
| Contact Compatibility | M6 | 
| Compatibility Code | LC1D | 
| IP Degree Of Protection | IP20 front face IEC 60529 | 
| Protective Treatment | TH IEC 60068-2-30 | 
| Pollution Degree | 3 | 