| Part Number | LC1D80004E7 |
|---|---|
| Country of Origin | CZ |
| UPC | 785901755869 |
| UPC11 | 78590175586 |
| EAN | 3389110074185 |
| Availability | N |
| Lead Time | 21 |
| UNSPSC | 39121529 |
| ECCN | EAR99 |
| HTs Code | 8536490065 |
| Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | I12 |
| Return Indicator | No |
| Depth | 4.92 inch |
| Height | 5.00 inch |
| Width | 3.78 inch |
| Weight | 3.88 pound |
| Range | TeSys |
|---|---|
| Product Name | TeSys D |
| Product Or Component Type | Contactor |
| Device Short Name | LC1D |
| Contactor Application | Resistive load |
| Utilisation Category | AC-1 |
| Poles Description | 4P |
| Power Pole Contact Composition | 4 NO |
| Ue Rated Operational Voltage | Power circuit <= 300 V DC 25...400 Hz Power circuit <= 690 V AC |
| Ie Rated Operational Current | 125 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit |
| Control Circuit Type | AC 50/60 Hz |
| Uc Control Circuit Voltage | 48 V AC 50/60 Hz |
| Uimp Rated Imp Wstd Voltage | 8 kV IEC 60947 |
| Overvoltage Category | III |
| Ith Cnvtl Free Air Therm Crrt | 125 A 140 °F (60 °C) power circuit |
| Irms Rated Making Capacity | 1100 A 440 V power circuit IEC 60947 |
| Rated Breaking Capacity | 1100 A 440 V power circuit IEC 60947 |
| Icw Rated Short-Time Wstd Crrt | 640 A 104 °F (40 °C) - 10 s power circuit 990 A 104 °F (40 °C) - 1 s power circuit 135 A 104 °F (40 °C) - 10 min power circuit 320 A 104 °F (40 °C) - 1 min power circuit |
| Associated Fuse Rating | 200 A gG <= 690 V type 1 power circuit 160 A gG <= 690 V type 2 power circuit |
| Average Impedance | 0.8 mOhm - Ith 125 A 50 Hz power circuit |
| Ui Rated Insulation Voltage | Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 |
| Electrical Durability | 0.8 Mcycles 125 A AC-1 <= 440 V |
| Power Dissipation Per Pole | 12.5 W AC-1 |
| Front Cover | Without |
| Mounting Support | Plate Rail |
| Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
| Product Certifications | LROS (Lloyds register of shipping) RINA BV CSA DNV CCC GOST GL UL |
| Connections - Terminals | Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end Power circuit connector 1 0.01…0.08 in² (4…50 mm²)flexible without cable end Power circuit connector 2 0.01…0.04 in² (4…25 mm²)flexible without cable end Power circuit connector 1 0.01…0.08 in² (4…50 mm²)flexible with cable end Power circuit connector 2 0.01…0.02 in² (4…16 mm²)flexible with cable end Power circuit connector 1 0.01…0.08 in² (4…50 mm²)solid without cable end Power circuit connector 2 0.01…0.04 in² (4…25 mm²)solid without cable end |
| Tightening Torque | Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm) |
| Operating Time | 20...35 ms closing 6...20 ms opening |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical Durability | 4 Mcycles |
| Operating Rate | 3600 cyc/h 140 °F (60 °C) |
| Coil Technology | Without built-in suppressor module |
| Ctrl Circuit Voltage Limits | 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz 1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz |
| Inrush Power In VA | 245 VA 60 Hz 0.75 68 °F (20 °C)) 245 VA 50 Hz 0.75 68 °F (20 °C)) |
| Hold-In Power Consumption Va | 26 VA 60 Hz 0.3 68 °F (20 °C)) 26 VA 50 Hz 0.3 68 °F (20 °C)) |
| Heat Dissipation | 6…10 W 50/60 Hz |
| Contact Compatibility | M1 |
| Compatibility Code | LC1D |
| IP Degree Of Protection | IP20 front face IEC 60529 |
| Protective Treatment | TH IEC 60068-2-30 |
| Pollution Degree | 3 |
| Ambient Air Temp For Op | -40…140 °F (-40…60 °C) 140…158 °F (60…70 °C) with derating |
| Ambient Air Temp For Storage | -76…176 °F (-60…80 °C) |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Fire Resistance | 1562 °F (850 °C) IEC 60695-2-1 |
| Flame Retardance | V1 UL 94 |
| Mechanical Robustness | Vibrations contactor open2 Gn, 5...300 Hz Shocks contactor open8 Gn for 11 ms Vibrations contactor closed3 Gn, 5...300 Hz Shocks contactor closed10 Gn for 11 ms |
| Height | 5.00 in (127 mm) |
Powered by ![]()
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366