LC1D256F7 is a compact 3-pole TeSys D contactor from Schneider Electric for motor applications 25A AC-3 11kW@400V. It provides a 110V 50/60Hz AC coil, 1NO+1NC auxiliary contacts and connection by ring-lugs screw terminals. LC1D256F7 is a 3-pole TeSys D contactor from Schneider Electric for motor applications 11kW@400V. It provides a 110V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts usable in safety applications thanks to its certified NC mirror contact and ring-lugs screw terminals. Compact, DIN-rail mounting, it procures high reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 45mm wide, for DIN-rail and panel mounting. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 110V AC coil that can be supplied at 50Hz or 60Hz. Provides 2 built-in auxiliary contacts 1NO + 1NC, NC is a certified mirror contact suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 25A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. All terminals are for cables equipped with ring lugs, providing high reliability in vibrating conditions.
Add to Quote CataloguePart Number | LC1D256F7 |
---|---|
Country of Origin | ID |
UPC | 785901830245 |
UPC11 | 78590183024 |
EAN | 3389110804492 |
Availability | N |
Lead Time | 55 |
UNSPSC | 39121529 |
ECCN | EAR99 |
HTs Code | 8536490065 |
Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | Yes |
Depth | 3.62 inch |
Height | 3.35 inch |
Width | 1.77 inch |
Weight | 0.82 pound |
Range | TeSys |
---|---|
Product Name | TeSys D |
Product Or Component Type | Contactor |
Device Short Name | LC1D |
Contactor Application | Resistive load Motor control |
Utilisation Category | AC-1 AC-3 AC-4 |
Poles Description | 3P |
Power Pole Contact Composition | 3 NO |
Ue Rated Operational Voltage | Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC |
Ie Rated Operational Current | 25 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit |
Motor Power kW | 5.5 kW 220...230 V AC 50/60 Hz AC-3) 11 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 415...440 V AC 50/60 Hz AC-3) 15 kW 500 V AC 50/60 Hz AC-3) 15 kW 660...690 V AC 50/60 Hz AC-3) 5.5 kW 400 V AC 50/60 Hz AC-4) |
Motor Power Hp (Ul / Csa) | 3 hp 230/240 V AC 50/60 Hz 1 phase 2 hp 115 V AC 50/60 Hz 1 phase 7.5 hp 230/240 V AC 50/60 Hz 3 phase 15 hp 460/480 V AC 50/60 Hz 3 phase 20 hp 575/600 V AC 50/60 Hz 3 phase 7.5 hp 200/208 V AC 50/60 Hz 3 phase |
Control Circuit Type | AC 50/60 Hz |
Uc Control Circuit Voltage | 110 V AC 50/60 Hz |
Auxiliary Contact Composition | 1 NO + 1 NC |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 |
Overvoltage Category | III |
Ith Cnvtl Free Air Therm Crrt | 10 A 140 °F (60 °C) signalling circuit 40 A 140 °F (60 °C) power circuit |
Irms Rated Making Capacity | 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 450 A 440 V power circuit IEC 60947 |
Rated Breaking Capacity | 450 A 440 V power circuit IEC 60947 |
Icw Rated Short-Time Wstd Crrt | 240 A 104 °F (40 °C) - 10 s power circuit 380 A 104 °F (40 °C) - 1 s power circuit 50 A 104 °F (40 °C) - 10 min power circuit 120 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit |
Associated Fuse Rating | 10 A gG signalling circuit IEC 60947-5-1 63 A gG <= 690 V type 1 power circuit 40 A gG <= 690 V type 2 power circuit |
Average Impedance | 2 mOhm - Ith 40 A 50 Hz power circuit |
Ui Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL |
Electrical Durability | 1.65 Mcycles 25 A AC-3 <= 440 V 1.4 Mcycles 40 A AC-1 <= 440 V |
Power Dissipation Per Pole | 3.2 W AC-1 1.25 W AC-3 |
Front Cover | With |
Mounting Support | Plate Rail |
Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
Product Certifications | CSA GL LROS (Lloyds register of shipping) UL RINA GOST DNV CCC BV |
Connections - Terminals | Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.39 in (10 mm)) |
Tightening Torque | Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 22.13 lbf.in (2.5 N.m) lugs-ring terminals flat Ø 8 mm M4 Power circuit 22.13 lbf.in (2.5 N.m) lugs-ring terminals Philips No 2 M4 |
Operating Time | 12...22 ms closing 4...19 ms opening |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical Durability | 15 Mcycles |
Operating Rate | 3600 cyc/h 140 °F (60 °C) |
Coil Technology | Without built-in suppressor module |
Ctrl Circuit Voltage Limits | 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz |
Inrush Power In VA | 70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C)) |
Hold-In Power Consumption Va | 7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C)) |
Heat Dissipation | 2…3 W 50/60 Hz |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Signalling Circuit Frequency | 25...400 Hz |
Minimum Switching Current | 5 mA signalling circuit |
Minimum Switching Voltage | 17 V signalling circuit |
Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Insulation Resistance | > 10 MOhm signalling circuit |
Contact Compatibility | M2 |
Compatibility Code | LC1D |
IP Degree Of Protection | IP20 front face IEC 60529 |