This Zelio RM35-A control relay allows monitoring of temperature control. This modular control relay is ideal for monitoring of electrical values and temperature variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems: ideal for refurbishment of old installations without using a PLC.
Add to Quote CataloguePart Number | RM35ATR5MW |
---|---|
Country of Origin | ID |
UPC | 785901505440 |
UPC11 | 78590150544 |
EAN | 3389119405171 |
Availability | N |
Lead Time | 27 |
UNSPSC | 39122331 |
ECCN | EAR99 |
HTs Code | 8536490075 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | CP2 |
Return Indicator | No |
Width | 1.38 inch |
Range Of Product | Zelio Control |
---|---|
Product Or Component Type | Modular measurement and control relays |
Relay Type | Temperature control relays |
Product Specific Application | For elevator machine rooms and 3-phase supplies |
Relay Name | RM35AT |
Relay Monitored Parameters | Overtemperature: 34...46°C Undertemperature: -1...11°C |
Time Delay Range | 0.1...10 s adjustable 0...10 % of the full scale value) |
Switching Capacity In Va | 1250 VA |
Minimum Switching Current | 10 mA 5 V DC |
Power Consumption In Va | 3.5 VA AC |
Utilisation Category | AC-12 IEC 60947-5-1 AC-13 IEC 60947-5-1 AC-14 IEC 60947-5-1 AC-15 IEC 60947-5-1 DC-12 IEC 60947-5-1 DC-13 IEC 60947-5-1 DC-14 IEC 60947-5-1 |
Reset Time | 8 s |
Maximum Switching Voltage | 250 V AC/DC |
Us Rated Supply Voltage | 24...240 V AC/DC |
[Us] Rated Supply Voltage | 24...240 V AC/DC |
Supply Voltage Limits | 20.4…264 V AC 21.6…264 V DC |
Power Consumption In W | 0.6 W DC |
Resistance Across Terminals | 1.33 kOhm temperature |
Width | 1.38 in (35 mm) |
Output Contacts | 2 NO |
Contacts Material | Cadmium free |
Nominal Output Current | 5 A |
Delay At Power Up | 0.2 s |
Measurement Accuracy | +/- 2 °C |
Response Time | <= 3.5 s + Tt in case of temperature fault) <= 3.5 s on disappearance of fault) |
Temperature Probe Type | Pt 100 - 3-wire |
Installed Device | Pt 100 probe cable length <= 10 m |
Marking | CE : EMC 89/336/EEC CE : 73/23/EEC |
Overvoltage Category | III IEC 60664-1 |
Insulation Resistance | > 500 MOhm 500 V DC between supply and relay output IEC 60255-5 > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 > 500 MOhm 500 V DC between supply and relay output IEC 60664-1 > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 > 1 MOhm 500 V DC between supply and measurement IEC 60664-1 |
Ui Rated Insulation Voltage | 250 V IEC 60664-1 |
Operating Voltage Tolerance | 10 % + 10 % Un DC - 15 % + 10 % Un AC |
Supply Frequency | 50/60 Hz +/- 10 % |
Insulation | Galvanic insulation between supply and measurement |
Operating Position | Any position without derating |
Connections - Terminals | Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end |
Tightening Torque | 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1 |
Housing Material | Self-extinguishing plastic |
Local Signalling | 1 LED Green power ON 1 LED Yellow correct temperature (high R1) 1 LED Yellow correct temperature (low R2) |
Mounting Support | 35 mm symmetrical DIN rail EN/IEC 60715 |
Electrical Durability | 100000 cycles |
Mechanical Durability | 30000000 cycles |
Operating Rate | <= 360 operations/hour full load |
Immunity To Microbreaks | 10 ms |
Electromagnetic Compatibility | Emission standard for industrial environments EN/IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 Immunity for industrial environments NF EN/IEC 61000-6-2 |
Standards | IEC 60255-6 NF EN 60255-6 |
Product Certifications | GL GOST C-tick CSA UL |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Ambient Air Temp For Op | -4…122 °F (-20…50 °C) |
Vibration Resistance | 0.35 mm 5…57.6 Hz)IEC 60068-2-6/IEC 60255-21-1 1 gn 57.6…150 Hz)IEC 60068-2-6/IEC 60255-21-1 |