| Part Number | SY500K500DL-PD |
|---|---|
| Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
| Depth | 42.13 inch |
| Height | 78.39 inch |
| Width | 204.72 inch |
| Weight | 18785.60 pound |
| Presentation | A high-performance, 3-phase, modular, scalable, power protection solution with industry-leading efficiency, capacity, and performance for medium to large data centers and mission critical environments. |
|---|---|
| Lead Time | Usually Ships within 6 Weeks |
| Provided Equipment | Assembly service Installation guide Network Management Card Start-Up Service User Manual |
| Bypass Voltage Tolerance | +/-10% settable from +/-4/6/8 and 10% |
| Colour | Black |
| Depth | 42.13 in (107 cm) |
| Height | 78.39 in (199.1 cm) |
| Product Weight | 18785.60 lb(US) (8521 kg) |
| Width | 204.72 in (520 cm) |
| Network Frequency | 40 - 70 Hz auto-sensing |
| Number Of Input Connectors | 1 Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G) |
| Input Voltage Limits | 340...460 V 400 V 408...552 V 480 V |
| Inputvolt_Other | 415 V |
| Max Short Time Withstd Current | 50 kA |
| Input Harmonic Distortion | Less than 5% for full load |
| Input Protection Type | 3-pole breaker |
| Input Voltage | 3 phase 3 phase |
| Rated Power In W | 500000 W |
| Max Configurable Power In W | 500000 W |
| Harmonic Distortion | Less than 2% |
| Output Frequency | 50 Hz sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal not synced 50 Hz +/- 0.1 % for 50 Hz nominal not synced 60 Hz sync to mains |
| Outputvolt_Other | 380 V 415 V |
| Ups Type | Double Conversion Online |
| Wave Type | Sine wave |
| Output Connector Type | Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G) 1 |
| Output Voltage Tolerance | +/-1% static and +/- 5% at 100% load step |
| Output Harmonic Distortion | < 2% linear load and < 3% non-linear load |
| Output Overload Operation | 10 minutes @ 125% and 60 seconds @ 150% |
| Bypass Type | Built-in Maintenance Bypass Built-in Static Bypass |
| Output Voltage | 480 V 3 phase 400 V 3 phase |
| Product Certifications | CUL Listed Eurobat General Purpose UL Listed |
| Standards | CSA C22.2 No.107.3-05 EN/IEC 62040-1-1 EN/IEC 62040-2 EN/IEC 62040-3 OSHPD UL 1778 UL 60950-1 |
| Ambient Air Temp For Op | 32…104 °F (0…40 °C) |
| Relative Humidity | 0…95 % |
| Operating Altitude | 0...3333 ft |
| Ambient Air Temp For Storage | 5…104 °F (-15…40 °C) |
| Storage Altitude | 0…50000 ft (0.00…15240.00 m) |
| Acoustic Level | 54 dBA |
| Heat Dissipation | 61893 Btu/h |
| Nema Degree Of Protection | NEMA 1 |
| IP Degree Of Protection | IP20 |
| Battery Type | VRLA |
| Number Of Battery Filled Slots | 32 |
| Battery Recharge Time | 3.5 h |
| Number Of Battery Repl Qty | 6 |
| Battery Overload Operation | 10 minutes @ 125% and 60 seconds @ 150% |
| Free Slots | 1 |
| Preinstalled Device | Network management card 2 with environmental monitoring, out of band access and Modbus |