| Part Number | SY40K40F |
|---|---|
| Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
| Depth | 35.51 inch |
| Height | 81.50 inch |
| Width | 23.62 inch |
| Weight | 1708.58 pound |
| Presentation | A high-efficiency 3-phase UPS that is scaleable as your data center grows up to 40KW/40KVA. Suitable for small to medium data center application. |
|---|---|
| Lead Time | Usually Ships within 3 Weeks |
| Provided Equipment | Network Management Card Start up included User Manual |
| Colour | Black |
| Depth | 35.51 in (90.2 cm) |
| Height | 81.50 in (207 cm) |
| Product Weight | 1708.58 lb(US) (775 kg) |
| Width | 23.62 in (60 cm) |
| Network Frequency | 50/60 Hz |
| Number Of Input Connectors | 1 Hard Wire 5-wire (3PH + N + G) |
| Input Voltage Limits | 177...240 V |
| Input Voltage | 3 phase |
| Rated Power In W | 40000 W |
| Max Configurable Power In W | 40000 W |
| Harmonic Distortion | Less than 5% |
| Output Frequency | 57...63 Hz for 60 Hz nominal sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal not synced |
| Ups Type | Double Conversion Online |
| Wave Type | Sine wave |
| Connections - Terminals | 1 screw terminals |
| Output Connector Type | Hard Wire 5-wire (3PH + N + G) 1 |
| Bypass Type | Built-in Static Bypass |
| Output Voltage | 120 V 208 V 208 V 3 phase |
| Product Certifications | CUL Listed |
| Standards | CSA C22.2 No.107.3-05 EN 50091-1 EN 50091-2 FCC Part 15 class A ISO 14001 ISO 9001 UL 1778 UL 60950 |
| Ambient Air Temp For Op | 32…104 °F (0…40 °C) |
| Relative Humidity | 0…95 % |
| Operating Altitude | 0...10000 ft |
| Ambient Air Temp For Storage | 5…104 °F (-15…40 °C) |
| Storage Altitude | 0…50000 ft (0.00…15240.00 m) |
| Acoustic Level | 64 dBA |
| Heat Dissipation | 11611 Btu/h |
| Nema Degree Of Protection | NEMA 1 |
| Battery Type | Lead-Acid battery |
| Number Of Battery Filled Slots | 4 |
| Battery Recharge Time | 2 h |
| Free Slots | 2 |
| Preinstalled Device | Network management card 2 - Masterpack for Symmetra 3-Phase |
| Control Panel | Multi-function LCD status and control console |
| Alarm | Alarm when on battery : distinctive low battery alarm : configurable delays |
| Emergency Power Off | Yes |
| EU RoHs Directive | Will be compliant on |
| Optimized Energy Efficiency | Energy efficient product |
| Warranty | 1 year on-site repair or replace with factory authorized Start-Up |