Part Number | SY250K500DR-PD |
---|---|
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
Depth | 42.13 inch |
Height | 78.39 inch |
Width | 145.67 inch |
Weight | 10813.68 pound |
Presentation | A high-performance, 3-phase, modular, scalable, power protection solution with industry-leading efficiency, capacity, and performance for medium to large data centers and mission critical environments. |
---|---|
Lead Time | Usually Ships within 6 Weeks |
Provided Equipment | Assembly service Installation guide Network Management Card Start-Up Service User Manual |
Colour | Black |
Depth | 42.13 in (107 cm) |
Height | 78.39 in (199.1 cm) |
Product Weight | 10813.68 lb(US) (4905 kg) |
Width | 145.67 in (370 cm) |
Network Frequency | 40 - 70 Hz auto-sensing |
Number Of Input Connectors | 1 Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G) |
Input Voltage Limits | 340...460 V 400 V 408...552 V 480 V |
Inputvolt_Other | 415 V |
Max Short Time Withstd Current | 50 kA |
Input Harmonic Distortion | Less than 5% for full load |
Input Protection Type | 3-pole breaker |
Input Voltage | 3 phase 3 phase |
Rated Power In W | 250000 W |
Max Configurable Power In W | 500000 W |
Harmonic Distortion | Less than 2% |
Output Frequency | 50 Hz sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal not synced 50 Hz +/- 0.1 % for 50 Hz nominal not synced 60 Hz sync to mains |
Outputvolt_Other | 415 V |
Ups Type | Double Conversion Online |
Wave Type | Sine wave |
Output Connector Type | Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G) 1 |
Output Voltage Tolerance | +/-1% static and +/- 5% at 100% load step |
Output Harmonic Distortion | < 2% linear load and < 3% non-linear load |
Output Overload Operation | 10 minutes @ 125% and 60 seconds @ 150% |
Bypass Type | Built-in Maintenance Bypass |
Output Voltage | 480 V 3 phase 400 V 3 phase |
Product Certifications | CUL Listed Eurobat General Purpose UL Listed |
Standards | CSA C22.2 No.107.3-05 EN/IEC 62040-1-1 EN/IEC 62040-2 EN/IEC 62040-3 OSHPD UL 1778 UL 60950-1 |
Ambient Air Temp For Op | 32…104 °F (0…40 °C) |
Relative Humidity | 0…95 % |
Operating Altitude | 0...30000 ft |
Ambient Air Temp For Storage | 5…104 °F (-15…40 °C) |
Storage Altitude | 0…50000 ft (0.00…15240.00 m) |
Acoustic Level | 54 dBA |
Heat Dissipation | 30946 Btu/h |
Nema Degree Of Protection | NEMA 1 |
IP Degree Of Protection | IP20 |
Battery Type | VRLA |
Number Of Battery Filled Slots | 16 |
Battery Recharge Time | 3.5 h |
Number Of Battery Repl Qty | 6 |
Battery Overload Operation | 10 minutes @ 125% and 60 seconds @ 150% |
Free Slots | 1 |
Preinstalled Device | Network management card 2 with environmental monitoring, out of band access and Modbus |
Control Panel | Touch Screen LCD User Interface |