Part Number | SSD1A335BDC1 |
---|---|
EAN | 3606489807894 |
Availability | N |
Lead Time | 45 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | CP2 |
Depth | 4.59 inch |
Height | 3.67 inch |
Width | 0.89 inch |
Weight | 0.66 pound |
Range Of Product | Harmony Relay |
---|---|
Product Or Component Type | Solid state relay |
Device Short Name | SSD1 |
Number Of Channels | 1 |
Number Of Phases | 1 phase |
Product Configuration Type | Relay configuration |
Mounting Support | 35 mm symmetrical DIN rail EN/IEC 60715 |
Rated Current | 35 A |
Contact Type | 1 NO |
Operating Frequency | 47...440 Hz |
Rated Duty | Uninterrupted |
Output Voltage | 48...600 V AC |
Control Circuit Voltage | 4...32 V DC |
Tightening Torque | 1.5...1.7 N.m control input 13...15 lb.in control input 1.5...1.7 N.m load output 13...15 lb.in load output |
Connections - Terminals | Input screw terminals Output screw terminals |
Dielectric Strength | 4 kV AC input/output circuit 4 kV AC input or output to case |
Rated Impulse Withstand Voltage | 6 kV input/output circuit 6 kV input or output to case |
Insulation Resistance | 1000 MOhm 500 V DC |
Local Signalling | Control voltage LED green) |
Pick-Up Voltage | 4 V DC turn-on |
Drop-Out Voltage | 1 V DC turn-off |
Input Current Range | 10…15 mA |
Solid State Output Type | SCR output |
Solid State Switching Type | Zero voltage switching |
Load Current | 0.15…35 A |
Transient Overvoltage | 1200 V |
Inrush Current | 1350 A |
Voltage Drop | <1.15 V on-state |
Motor Controller Rating | 1.5 kW 2 hp 120 V AC 3.73 kW 5 hp 240 V AC 7.46 kW 10 hp 480 V AC |
Electromagnetic Compatibility | Electrostatic discharge 6 kV criteria A contact discharge IEC 61000-4-2 Electrostatic discharge 8 kV criteria A air discharge IEC 61000-4-2 Conducted RF disturbances 10 V, 0.15...80 MHz criteria A level 3 IEC 61000-4-6 Electrical fast transient/burst immunity test 2 kV, 5/100 kHz criteria B output ports IEC 61000-4-4 Electrical fast transient/burst immunity test 1 kV, 5/100 kHz criteria B input ports IEC 61000-4-4 Radiated radio-frequency electromagnetic field immunity test 10 V/m, 80 MHz...1 GHz criteria A IEC 61000-4-3 Radiated radio-frequency electromagnetic field immunity test 3 V/m, 1.4...2 GHz criteria A IEC 61000-4-3 Radiated radio-frequency electromagnetic field immunity test 1 V/m, 2...2.7 GHz criteria A IEC 61000-4-3 Surge immunity test 1 kV criteria A output ports line to line IEC 61000-4-5 Surge immunity test 2 kV criteria B output ports line to earth IEC 61000-4-5 Radiated emission environment B for DC input supply IEC 60947-4-3 Conducted emission environment B for DC input supply IEC 60947-4-3 Immunity to microbreaks and voltage drops 30 %, 500 ms criteria A IEC 61000-4-11 Immunity to microbreaks and voltage drops 100 %, 20 ms criteria B IEC 61000-4-11 |
Device Form Designation | Form 5 |
Maximum I²T For Fusing | 8320 A².s 10 ms 7593 A².s 8.33 ms |
Leakage Current | 1 mA off-state |
Dv/Dt | 500 V/µs off-state at maximum rated voltage |
Response Time | 0.5 cycle turn-on) 0.5 cycle turn-off) |
Power Factor | with maximum load |
Short Circuit Protection Coordination | Type 1 Type 2 |
Overvoltage Category | III |
Width | 0.89 in (22.5 mm) |
Height | 3.67 in (93.2 mm) |
Depth | 4.59 in (116.5 mm) |
Product Weight | 0.66 lb(US) (0.298 kg) |
Device Presentation | Complete product |
Flammability Rating | V-0 UL 94 |
Vibration Resistance | 0.75 mm 10…150 Hz) EN/IEC 60068-2-6 |
Shock Resistance | peak acceleration EN/IEC 60068-2-27 peak acceleration EN/IEC 60068-2-27 |
Pollution Degree | 2 |
Standards | IEC 61373:class B category 1 IEC 60947-4-3 IEC 62314 IEC 60950-1 CSA C22.2 No 14-13 UL 508 |
IP Degree Of Protection | IP20 |
Ambient Air Temp For Op | -40…176 °F (-40…80 °C) |