This Altistart 01 soft starter is DIN rail mounted and can feed 3-phase asynchronous motors with a rating up to 9A. This Altistart 01 can be used for a motor rated power up to 1.5kW or 2hp for 3-phase (200V to 240V AC). This DIN rail mounted soft starter is designed to enable smooth start for simple machines such as conveyors, conveyor belts, pumps, fans, compressors, automatic doors and gates, small cranes and belt-driven machinery. It is 45mm wide, this makes it one of the smallest soft starters on the market; it can be installed nearly everywhere. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Simple setup with only 2 settings: possible to configure by non-specialists. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
Brand: Telemecanique
Add to Quote CataloguePart Number | ATS01N209RT |
---|---|
Country of Origin | DE |
UPC | 785901875871 |
UPC11 | 78590187587 |
EAN | 3389110667240 |
Availability | S |
Lead Time | 33 |
UNSPSC | 39121521 |
ECCN | EAR99 |
HTs Code | 8504404000 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I11 |
Return Indicator | Yes |
Depth | 5.16 inch |
Height | 4.88 inch |
Width | 1.77 inch |
Weight | 0.93 pound |
Range Of Product | Altistart 01 |
---|---|
Product Or Component Type | Soft starter |
Product Destination | Asynchronous motors |
Product Specific Application | Simple machine |
Device Short Name | ATS01 |
Network Number Of Phases | 3 phase |
[Us] Rated Supply Voltage | 460...480 V - 10...10 % |
Motor Power Hp | 5 hp, 3 phase 460...480 V |
Icl Starter Rating | 9 A |
Utilisation Category | AC-53B EN/IEC 60947-4-2 |
Current Consumption | 45 A at nominal load |
Type Of Start | Start with voltage ramp |
Power Dissipation In W | 4 W at full load and at end of starting 94 W in transient state |
Assembly Style | With heat sink |
Function Available | Integrated bypass |
Supply Voltage Limits | 414…528 V |
Supply Frequency | 50...60 Hz - 5...5 % |
Network Frequency | 47.5...63 Hz |
Output Voltage | <= power supply voltage |
Uc Control Circuit Voltage | Built into the starter |
Starting Time | 1 s / 100 5 s / 20 10 s / 10 Adjustable from 1 to 10 s |
Deceleration Time Symb | Adjustable from 1 to 10 s |
Starting Torque | 30...80 % of starting torque of motor connected directly on the line supply |
Discrete Input Type | Logic LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm |
Discrete Input Voltage | 24...40 V |
Discrete Input Logic | Positive LI1, LI2, BOOST < 5 V <= 0.2 mA > 13 V, >= 0.5 mA |
Discrete Output Current | 2 A DC-13 3 A AC-15 |
Discrete Output Type | Open collector logic LO1 end of starting signal Relay outputs R1A, R1C NO |
Discrete Output Voltage | 24 V 6...30 V) open collector logic |
Minimum Switching Current | 10 mA 6 V DC relay outputs |
Maximum Switching Current | Relay outputs 2 A 250 V AC cos phi = 0.5 20 ms inductive Relay outputs 2 A 30 V DC cos phi = 0.5 20 ms inductive |
Display Type | 1 LED Green)starter powered up 1 LED Yellow)nominal voltage reached |
Tightening Torque | 16.82…22.13 lbf.in (1.9…2.5 N.m) 4.43 lbf.in (0.5 N.m) |
Electrical Connection | 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit Screw connector - rigid 1 0.5...2.5 mm² AWG 14 control circuit 4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit Screw connector - rigid 2 0.5...1 mm² AWG 17 control circuit Screw connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit 4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuit Screw connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit 4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit 4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuit Screw connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit |
Marking | CE |
Operating Position | Vertical +/- 10 degree |
Height | 4.88 in (124 mm) |
Width | 1.77 in (45 mm) |
Depth | 5.16 in (131 mm) |
Product Weight | 0.93 lb(US) (0.42 kg) |
Compatibility Code | ATS01N2 |
Electromagnetic Compatibility | Conducted and radiated emissions level B CISPR 11 Conducted and radiated emissions level B IEC 60947-4-2 Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-2 EMC immunity EN 50082-1 EMC immunity EN 50082-2 Harmonics IEC 1000-3-2 Harmonics IEC 1000-3-4 Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Micro-cuts and voltage fluctuation IEC 61000-4-11 Voltage/current impulse level 3 IEC 61000-4-5 |
Standards | EN/IEC 60947-4-2 |
Product Certifications | CCC B44.1-96/ASME A17.5 for starter wired to the motor delta terminal GOST CSA UL C-tick |
IP Degree Of Protection | IP20 |
Pollution Degree | 2 EN/IEC 60947-4-2 |
Vibration Resistance | 1 gn 13…150 Hz)EN/IEC 60068-2-6 1.5 mm peak to peak 3…13 Hz)EN/IEC 60068-2-6 |
Shock Resistance | 15 gn 11 ms EN/IEC 60068-2-27 |
Relative Humidity | 5…95 % without condensation or dripping water EN/IEC 60068-2-3 |
Ambient Air Temp For Op | 14…104 °F (-10…40 °C) without derating) 104…122 °F (40…50 °C) with current derating of 2 % per °C) |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366