This XCSPR Safety Limit Switch has a 30 mm stainless steel spindle, a double insulated plastic enclosure and a 1/2″ NPT cable gland entry. It has 1 normally open and 1 normally closed break-before-make (slow break) contacts. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Brand: Telemecanique
Add to Quote Catalogue| Part Number | XCSPR553 |
|---|---|
| Country of Origin | FR |
| UPC | 785901177142 |
| UPC11 | 78590117714 |
| EAN | 3389110177145 |
| Availability | N |
| Lead Time | 20 |
| UNSPSC | 39122213 |
| ECCN | EAR99 |
| HTs Code | 8536509065 |
| Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | T |
| Return Indicator | No |
| Depth | 2.36 inch |
| Height | 3.78 inch |
| Width | 1.18 inch |
| Weight | 0.23 pound |
| Range Of Product | Preventa Safety detection |
|---|---|
| Product Or Component Type | Guard switch |
| Component Name | XCSPR |
| Material | Plastic |
| Head Type | Turret head rotary axis |
| Insulation | Double insulated |
| Type Of Operator | Spindle 30 mm |
| Electrical Connection | Terminal |
| Contacts Type And Composition | 1 NC + 1 NO |
| Contact Operation | Slow-break, break before make |
| Clamping Connection Capacity | 1 x 0.5...2 x 1.5 mm² with or without cable end |
| Cable Entry | 1 entry tapped 1/2" NPT |
| Number Of Poles | 2 |
| Cable Outer Diameter | 0.28…0.39 in (7…10 mm) |
| Positive Opening | With NC contact |
| Tripping Angle | 5 ° |
| Mechanical Durability | 1000000 cycles |
| Minimum Torque For Tripping | 0.89 lbf.in (0.1 N.m) |
| Positive Opening Min Torque | 2.21 lbf.in (0.25 N.m) |
| Contact Code Designation | A300, AC-15 (Ue = 120 V, Ie = 6 A)EN/IEC 60947-5-1 A300, AC-15 (Ue = 240 V, Ie = 3 A)EN/IEC 60947-5-1 Q300, DC-13 (Ue = 125 V, Ie = 0.55 A)EN/IEC 60947-5-1 Q300, DC-13 (Ue = 250 V, Ie = 0.27 A)EN/IEC 60947-5-1 |
| Ithe Cnvtl Enclosed Therm Crrt | 10 A |
| Ui Rated Insulation Voltage | 300 VUL 508 300 VCSA C22.2 No 14 500 V 3)EN/IEC 60947-1 |
| Uimp Rated Imp Wstd Voltage | 6 kV EN/IEC 60947-5-1 |
| Resistance Across Terminals | 30 mOhm EN/IEC 60947-5-4 |
| Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
| Safety Level | Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508 |
| Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
| Enclosure Material | Polyamide PA66 fibre glass impregnated |
| Lever Material | Stainless steel |
| Width | 1.18 in (30 mm) |
| Height | 3.78 in (96 mm) |
| Depth | 2.36 in (60 mm) |
| Product Weight | 0.23 lb(US) (0.105 kg) |
| Standards | EN/IEC 60947-5-1 EN/ISO 12100 UL 508 EN 1088/ISO 14119 EN/IEC 60947-5-4 CSA C22.2 No 14 EN/IEC 60204-1 |
| Product Certifications | CSA UL BG |
| Protective Treatment | TC TH |
| Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
| Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
| Vibration Resistance | 50 gn 10…500 Hz)IEC 60068-2-6 |
| Shock Resistance | 50 gn 11 ms IEC 60068-2-27 |
| Electrical Shock Protect Class | Class II EN/IEC 61140 |
| IP Degree Of Protection | IP67 IEC 60529 |
| Category | 22411 - LIMIT SWITCHES,IEC,XCKJ |
| Discount Schedule | T |
| GTIN | 00785901177142 |
| Nbr. Of Units In Pkg. | 1 |
| Country Of Origin | FR |
| Green Premium Status | Green Premium product |
| EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Mercury Free | Yes |
Powered by ![]()
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366