| Part Number | XCSE7311MH00300 |
|---|---|
| Country of Origin | FR |
| UPC | 785901657071 |
| UPC11 | 78590165707 |
| EAN | 0785901657071 |
| Availability | N |
| Lead Time | 40 |
| UNSPSC | 39122213 |
| ECCN | EAR99 |
| HTs Code | 8536509065 |
| Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
| Discount Schedule | T |
| Return Indicator | No |
| Depth | 1.73 inch |
| Height | 5.75 inch |
| Width | 3.86 inch |
| Weight | 2.51 pound |
| Range Of Product | Preventa Safety detection |
|---|---|
| Product Or Component Type | Safety switch |
| Component Name | XCSE |
| Design | Rectangular |
| Material | Metal |
| Head Type | Key operated turret head |
| Contacts Type And Composition | 2 NC + 1 NO |
| Contact Operation | Slow-break, break before make |
| Solenoid Contacts Type Compo | 2 NC slow-break, simultaneous) |
| Cable Entry | 2 entries tapped Pg 13.5 |
| Electromagnet Interlocking | Locking on de-energisation and unlocking on energisation of solenoid |
| [Us]&Nbsp;Solenoid&Nbsp;Rated&Nbsp;Supply Voltage | 24 V - 20...10 % |
| Cable Outer Diameter | 0.35…0.47 in (9…12 mm) |
| Electrical Connection | Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end |
| Number Of Poles | 3 |
| Locking Options Description | With interlocking, locking by solenoid |
| Local Signalling | Guard open/guard closed and locked 2 LEDs green or orange) |
| Signalling Circuit Voltage | 24/48 V 20...52 V) |
| Positive Opening | With NC contact |
| Supply Voltage Type | AC/DC |
| Supply Frequency | 50/60 Hz |
| Load Factor | 1 |
| Power Consumption In Va | 10 VA inrush 10 VA sealed |
| Signalling Circuit Type | AC/DC |
| Signalling Circuit Consumption | 7 mA |
| Mechanical Durability | 1000000 cycles |
| Minimum Actuation Speed | 0.03 ft/s (0.01 m/s) |
| Maximum Actuation Speed | 1.64 ft/s (0.5 m/s) |
| Ie Rated Operational Current | 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 |
| Ithe Cnvtl Enclosed Therm Crrt | 6 A |
| Ui Rated Insulation Voltage | 50 VEN/IEC 60947-1 signalling circuit |
| Uimp Rated Imp Wstd Voltage | 6 kV EN/IEC 60947-5-1 |
| Protection Type | Overvoltage protection signalling circuit |
| Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
| Actutr Forcible Withdrawal Rtc | 2000 N |
| Actutr Force For Extractn | 20 N |
| Operating Rate | 10 cyc/mn for maximum durability |
| Safety Level | Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
| Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
| Body Material | Zamak |
| Head Material | Zamak |
| Depth | 1.73 in (44 mm) |
| Height | 5.75 in (146 mm) |
| Width | 3.86 in (98 mm) |
| Product Weight | 2.51 lb(US) (1.14 kg) |
| Standards | EN/ISO 12100 EN/IEC 60204-1 EN/IEC 60947-5-1 CSA C22.2 No 14 UL 508 EN 1088/ISO 14119 |
| Product Certifications | UL CSA |
| Protective Treatment | TC |
| Ambient Air Temp For Op | -13…104 °F (-25…40 °C) |
| Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Powered by ![]()