| Part Number | XSAV11373TFEX |
|---|---|
| Country of Origin | FR |
| UPC | 389119040921 |
| UPC11 | 38911904092 |
| EAN | 3389119040921 |
| Availability | N |
| Lead Time | 30 |
| ECCN | EAR99 |
| HTs Code | 8536507000 |
| Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | DS2 |
| Return Indicator | No |
| Height | 1.18 inch |
| Range Of Product | OsiSense XS ATEX D |
|---|---|
| Series Name | Application |
| Sensor Type | Inductive proximity sensor |
| Device Application | Rotation monitoring ATEX dust |
| Sensor Name | XSA |
| Sensor Design | Cylindrical M30 |
| Size | 81 mm |
| Body Type | Fixed |
| Flush Mountability | Flush mountable |
| Material | Metal |
| Enclosure Material | Nickel plated brass |
| Sn Nominal Sensing Distance | 0.39 in (10 mm) |
| Type Of Output Signal | Discrete |
| Wiring Techniquees | 3-wire |
| Discrete Output Function | 1 NC |
| Output Circuit Type | DC |
| Discrete Output Type | PNP |
| Electrical Connection | Cable |
| Cable Length | 6.56 ft (2 m) |
| Us Rated Supply Voltage | 12...48 V DC reverse polarity protection |
| Switching Capacity In Ma | <= 200 mA overload and short-circuit protection |
| IP Degree Of Protection | IP67 IEC 60529 |
| Thread Type | M30 x 1.5 |
| Detection Face | Frontal |
| Front Material | PPS |
| Sensing Range | > 0.31...0.59 in (> 8...15 mm) |
| Adjustable Frequency Range | 6…150 cyc/mn |
| Operating Zone | 0.00…0.31 in (0…8 mm) |
| Differential Travel | 3...15% of Fr |
| Repeat Accuracy | 3% of Sr |
| Cable Composition | 3 x 0.34 mm² |
| Wire Insulation Material | PvR |
| Status Led | Output state 1 LED red) |
| Supply Voltage Limits | 10…58 V DC |
| Switching Frequency | <= 100 Hz |
| Voltage Drop | <1.8 V closed state) |
| Current Consumption | 0...15 mA no-load |
| Run-Up Delay At Power-Up | 9 s standard |
| Marking | II2 D-Ex tb IIIC T90°C Db IP67 |
| Threaded Length | 2.24 in (57 mm) |
| Height | 1.18 in (30 mm) |
| Length | 3.19 in (81 mm) |
| Environmental Characteristic | Hazardous location |
| Standards | EN/IEC 60079-31 EN/IEC 60079-0 |
| Directives | 2014/34/EU - ATEX directive |
| Product Certifications | INERIS 04ATEX0022X IEC-Ex INE 17.0006 |
| Ambient Air Temp For Op | -40…140 °F (-40…60 °C) |
| Dust Zone | Zone 21 - 22 |
| Category | 22486 - SENSORS, PROXIMITY |
| Discount Schedule | DS2 |
Powered by ![]()
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366