Reversing contactor TeSys LC2-D – 3 poles – AC-3 – 440V 40A – coil 120V AC 60 Hz – TQPKG
LC2D40AG7TQ
Reversing contactor TeSys LC2-D – 3 poles – AC-3 – 440V 40A – coil 120V AC 60 Hz – TQPKG
Specifications
Part Number LC2D40AG7TQ
Country of Origin FR
UPC 785901556961
UPC11 78590155696
EAN 3606480787522
Availability N
Lead Time 43
UNSPSC 39121529
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I12
Return Indicator Yes
Depth 4.72 inch
Height 4.80 inch
Width 4.69 inch
Weight 4.12 pound
Characteristics
Range TeSys
Product Name TeSys D
Product Or Component Type Reversing contactor
Device Short Name LC2D
Contactor Application Resistive load Motor control
Utilisation Category AC-1 AC-3
Device Presentation Preassembled with reversing power busbar
Poles Description 3P
Power Pole Contact Composition 3 NO
Ue Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
Ie Rated Operational Current 60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
Motor Power kW 18.5 kW 380...400 V AC 50 Hz 11 kW 220...230 V AC 50 Hz 22 kW 415...440 V AC 50 Hz 22 kW 500 V AC 50 Hz 30 kW 660...690 V AC 50 Hz
Motor Power Hp (Ul / Csa) 10 hp 200/208 V AC 60 Hz 3 phase 3 hp 115 V AC 60 Hz 1 phase 30 hp 575...600 V AC 60 Hz 3 phase 30 hp 460...480 V AC 60 Hz 3 phase 5 hp 230...240 V AC 60 Hz 1 phase 10 hp 230...240 V AC 60 Hz 3 phase
Control Circuit Type AC 60 Hz
Uc Control Circuit Voltage 120 V AC 60 Hz
Auxiliary Contact Composition 1 NO + 1 NC
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947
Overvoltage Category III
Ith Cnvtl Free Air Therm Crrt 10 A 140 °F (60 °C) signalling circuit 60 A 140 °F (60 °C) power circuit
Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947-4
Rated Breaking Capacity 800 A 220/415/440 V power circuit IEC 60947
Icw Rated Short-Time Wstd Crrt 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit 320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit
Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1
Average Impedance 1.5 mOhm - Ith 60 A 50 Hz power circuit
Ui Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
Electrical Durability 1.5 Mcycles 40 A AC-3 <= 440 V 1.4 Mcycles 60 A AC-1 <= 440 V
Power Dissipation Per Pole 5.4 W AC-1 3.4 W AC-3
Front Cover With
Interlocking Type Mechanical
Mounting Support Plate Rail
Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
Product Certifications CCC CSA DNV EAC
Connections - Terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end Power circuit screw clamp terminals 1 0.00…0.05 in² (1…35 mm²)flexible without cable end Power circuit screw clamp terminals 2 0.00…0.04 in² (1…25 mm²)flexible without cable end Power circuit screw clamp terminals 1 0.00…0.05 in² (1…35 mm²)flexible with cable end Power circuit screw clamp terminals 2 0.00…0.04 in² (1…25 mm²)flexible with cable end Power circuit screw clamp terminals 1 0.00…0.05 in² (1…35 mm²)solid without cable end Power circuit screw clamp terminals 2 0.00…0.04 in² (1…25 mm²)solid without cable end
Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.16 in (4 mm) Power circuit 44.25 lbf.in (5 N.m) EverLink BTR screw connectors 0.00…0.04 in² (1…25 mm²) hexagonal 0.16 in (4 mm)
Operating Time 4...19 ms opening 12...26 ms closing
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability 6000000 cycles
Operating Rate 3600 cyc/h 140 °F (60 °C)
Coil Technology Built-in bidirectional peak limiting diode suppressor
Ctrl Circuit Voltage Limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 60 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 60 Hz
Inrush Power In VA 160 VA 60 Hz 0.75 68 °F (20 °C))
Hold-In Power Consumption Va 13 VA 68 °F (20 °C)) 0.3 60 Hz
Heat Dissipation 4…5 W 60 Hz
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
Signalling Circuit Frequency 25...400 Hz
Minimum Switching Current 5 mA signalling circuit
Minimum Switching Voltage 17 V signalling circuit
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Insulation Resistance > 10 MOhm signalling circuit
Contact Compatibility M2