Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Reversing contactor – 575 V AC 40 A – IEC
LC2D40G7
Reversing contactor – 575 V AC 40 A – IEC
Specifications
Part Number LC2D40G7
Country of Origin CZ
UPC 785901455257
UPC11 78590145525
EAN 3389110455250
Availability S
Lead Time 48
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I12
Return Indicator Yes
Depth 5.59 inch
Height 5.20 inch
Width 6.50 inch
Weight 5.29 pound
Characteristics
Range Of Product TeSys D
Product Or Component Type Reversing contactor
Device Short Name LC2D
Contactor Application Motor control
Utilisation Category AC-4 AC-2 AC-3
Control Circuit Type AC
Coil Type Standard
Poles Description 3P
Pole Contact Composition 3 NO
Ie Rated Operational Current Power circuit 40 A AC AC-3 140 °F (60 °C))
Motor Power kW 11 kW 220...240 V AC 50/60 Hz 22 kW 415 V AC 50/60 Hz 22 kW 440 V AC 50/60 Hz 22 kW 500 V AC 50/60 Hz 30 kW 660...690 V AC 50/60 Hz 18.5 kW 380...400 V AC 50/60 Hz
[Uc] Control Circuit Voltage 120 V AC 50/60 Hz
Connections - Terminals Control circuit 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit 1 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit 2 0.00…0.01 in² (1…4 mm²)solid without cable end Power circuit 1 0.00…0.05 in² (1…35 mm²)flexible with cable end Power circuit 1 0.00…0.05 in² (1…35 mm²)flexible without cable end Power circuit 1 0.00…0.05 in² (1…35 mm²)solid without cable end Power circuit 2 0.00…0.04 in² (1…25 mm²)flexible with cable end Power circuit 2 0.00…0.04 in² (1…25 mm²)flexible without cable end Power circuit 2 0.00…0.04 in² (1…25 mm²)solid without cable end Power circuit 2 0.00…0.05 in² (1…35 mm²)flexible with cable end Power circuit 2 0.00…0.05 in² (1…35 mm²)flexible without cable end Power circuit 2 0.00…0.05 in² (1…35 mm²)solid without cable end
Assembly Style Ready assembled
Coil Technology Without built-in bidirectional peak limiting diode suppressor
Protective Cover With
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
Auxiliary Contact Composition 1 NO + 1 NC
Interlocking Type Mechanical
Ctrl Circuit Voltage Limits Drop-out 0.3...0.6 Uc 50/60 Hz 140 °F (60 °C)) Operational 0.8...1.1 Uc 50 Hz 140 °F (60 °C)) Operational 0.85...1.1 Uc 60 Hz 140 °F (60 °C))
Ui Rated Insulation Voltage Control circuit 600 V CSA Control circuit 600 V UL Power circuit 600 V CSA Power circuit 600 V UL Control circuit 690 V IEC 60947-1 Power circuit 690 V IEC 60947-1
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947
Overvoltage Category III
Mounting Support Rail Plate
Flame Retardance V1 UL 94
Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) 0.00…0.00 in² (1…2.5 mm²) flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) 0.00…0.00 in² (1…2.5 mm²) Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) 0.00…0.01 in² (1…4 mm²) flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) 0.00…0.01 in² (1…4 mm²) Philips No 2 Power circuit 44.25 lbf.in (5 N.m) 0.00…0.04 in² (1…25 mm²) hexagonal Power circuit 70.81 lbf.in (8 N.m) 0.00…0.05 in² (1…35 mm²) hexagonal
Ue Rated Operational Voltage Power circuit <= 1000 V AC 25...400 Hz
Ith Cnvtl Free Air Therm Crrt 10 A 140 °F (60 °C) control circuit 60 A 140 °F (60 °C) power circuit
Irms Rated Making Capacity 140 A AC control circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947
Rated Breaking Capacity 800 A 440 V power circuit IEC 60947
Associated Fuse Rating 10 A gG control circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit
Average Impedance Ith 60 A 50 Hz power circuit
Power Dissipation Per Pole 2.4 W AC-3 - Ith 60 A
Inrush Power In VA 200 VA 0.75 68 °F (20 °C)) 220 VA 0.75 68 °F (20 °C))
Hold-In Power Consumption Va 20 VA 50 Hz 0.3 68 °F (20 °C)) 22 VA 60 Hz 0.3 68 °F (20 °C)) 26 VA 50 Hz 0.3 68 °F (20 °C)) 26 VA 60 Hz 0.3 68 °F (20 °C))
Operating Time 12...26 ms closing 4...19 ms opening
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability 6000000 cycles
Operating Rate 3600 cyc/h 140 °F (60 °C)
Minimum Switching Current 5 mA control circuit
Minimum Switching Voltage 17 V control circuit
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts
Insulation Resistance > 10 MOhm control circuit
Height 5.20 in (132 mm)
Width 6.50 in (165 mm)
Depth 5.59 in (142 mm)
Product Weight 5.29 lb(US) (2.4 kg)
Standards CSA C22.2 No 14 IEC 60947-4-1 EN 60947-4-1 UL 508 IEC 60947-5-1 EN 60947-5-1
Product Certifications GOST CCC GL LROS (Lloyds register of shipping) BV UL DNV RINA CSA
IP Degree Of Protection IP2x IEC 60529 IP2x VDE 0106
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews