Part Number | LC2D40G7 |
---|---|
Country of Origin | CZ |
UPC | 785901455257 |
UPC11 | 78590145525 |
EAN | 3389110455250 |
Availability | S |
Lead Time | 48 |
ECCN | EAR99 |
HTs Code | 8536490065 |
Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | Yes |
Depth | 5.59 inch |
Height | 5.20 inch |
Width | 6.50 inch |
Weight | 5.29 pound |
Range Of Product | TeSys D |
---|---|
Product Or Component Type | Reversing contactor |
Device Short Name | LC2D |
Contactor Application | Motor control |
Utilisation Category | AC-4 AC-2 AC-3 |
Control Circuit Type | AC |
Coil Type | Standard |
Poles Description | 3P |
Pole Contact Composition | 3 NO |
Ie Rated Operational Current | Power circuit 40 A AC AC-3 140 °F (60 °C)) |
Motor Power kW | 11 kW 220...240 V AC 50/60 Hz 22 kW 415 V AC 50/60 Hz 22 kW 440 V AC 50/60 Hz 22 kW 500 V AC 50/60 Hz 30 kW 660...690 V AC 50/60 Hz 18.5 kW 380...400 V AC 50/60 Hz |
[Uc] Control Circuit Voltage | 120 V AC 50/60 Hz |
Connections - Terminals | Control circuit 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit 1 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit 2 0.00…0.01 in² (1…4 mm²)solid without cable end Power circuit 1 0.00…0.05 in² (1…35 mm²)flexible with cable end Power circuit 1 0.00…0.05 in² (1…35 mm²)flexible without cable end Power circuit 1 0.00…0.05 in² (1…35 mm²)solid without cable end Power circuit 2 0.00…0.04 in² (1…25 mm²)flexible with cable end Power circuit 2 0.00…0.04 in² (1…25 mm²)flexible without cable end Power circuit 2 0.00…0.04 in² (1…25 mm²)solid without cable end Power circuit 2 0.00…0.05 in² (1…35 mm²)flexible with cable end Power circuit 2 0.00…0.05 in² (1…35 mm²)flexible without cable end Power circuit 2 0.00…0.05 in² (1…35 mm²)solid without cable end |
Assembly Style | Ready assembled |
Coil Technology | Without built-in bidirectional peak limiting diode suppressor |
Protective Cover | With |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Auxiliary Contact Composition | 1 NO + 1 NC |
Interlocking Type | Mechanical |
Ctrl Circuit Voltage Limits | Drop-out 0.3...0.6 Uc 50/60 Hz 140 °F (60 °C)) Operational 0.8...1.1 Uc 50 Hz 140 °F (60 °C)) Operational 0.85...1.1 Uc 60 Hz 140 °F (60 °C)) |
Ui Rated Insulation Voltage | Control circuit 600 V CSA Control circuit 600 V UL Power circuit 600 V CSA Power circuit 600 V UL Control circuit 690 V IEC 60947-1 Power circuit 690 V IEC 60947-1 |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 |
Overvoltage Category | III |
Mounting Support | Rail Plate |
Flame Retardance | V1 UL 94 |
Tightening Torque | Control circuit 15.05 lbf.in (1.7 N.m) 0.00…0.00 in² (1…2.5 mm²) flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) 0.00…0.00 in² (1…2.5 mm²) Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) 0.00…0.01 in² (1…4 mm²) flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) 0.00…0.01 in² (1…4 mm²) Philips No 2 Power circuit 44.25 lbf.in (5 N.m) 0.00…0.04 in² (1…25 mm²) hexagonal Power circuit 70.81 lbf.in (8 N.m) 0.00…0.05 in² (1…35 mm²) hexagonal |
Ue Rated Operational Voltage | Power circuit <= 1000 V AC 25...400 Hz |
Ith Cnvtl Free Air Therm Crrt | 10 A 140 °F (60 °C) control circuit 60 A 140 °F (60 °C) power circuit |
Irms Rated Making Capacity | 140 A AC control circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947 |
Rated Breaking Capacity | 800 A 440 V power circuit IEC 60947 |
Associated Fuse Rating | 10 A gG control circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit |
Average Impedance | Ith 60 A 50 Hz power circuit |
Power Dissipation Per Pole | 2.4 W AC-3 - Ith 60 A |
Inrush Power In VA | 200 VA 0.75 68 °F (20 °C)) 220 VA 0.75 68 °F (20 °C)) |
Hold-In Power Consumption Va | 20 VA 50 Hz 0.3 68 °F (20 °C)) 22 VA 60 Hz 0.3 68 °F (20 °C)) 26 VA 50 Hz 0.3 68 °F (20 °C)) 26 VA 60 Hz 0.3 68 °F (20 °C)) |
Operating Time | 12...26 ms closing 4...19 ms opening |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical Durability | 6000000 cycles |
Operating Rate | 3600 cyc/h 140 °F (60 °C) |
Minimum Switching Current | 5 mA control circuit |
Minimum Switching Voltage | 17 V control circuit |
Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts |
Insulation Resistance | > 10 MOhm control circuit |
Height | 5.20 in (132 mm) |
Width | 6.50 in (165 mm) |
Depth | 5.59 in (142 mm) |
Product Weight | 5.29 lb(US) (2.4 kg) |
Standards | CSA C22.2 No 14 IEC 60947-4-1 EN 60947-4-1 UL 508 IEC 60947-5-1 EN 60947-5-1 |
Product Certifications | GOST CCC GL LROS (Lloyds register of shipping) BV UL DNV RINA CSA |
IP Degree Of Protection | IP2x IEC 60529 IP2x VDE 0106 |