TeSys U reversing module for vertical mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 110-240V AC / 110-220V DC. To be used with an advanced power base LUB120, LUB320, or LUB380 equipped with a Control Unit LUC*FU type. To be associated with an assembling connector LU9MR1C and a control terminal block LU9M1 to complete the vertical mounting. Green Premium compliant (RoHS/REACh).
Add to Quote Catalogue| Part Number | LU2MB0FU |
|---|---|
| Country of Origin | FR |
| UPC | 785901202622 |
| UPC11 | 78590120262 |
| EAN | 3389110363807 |
| Availability | S |
| Lead Time | 3 |
| UNSPSC | 39121521 |
| ECCN | EAR99 |
| HTs Code | 8536200040 |
| Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | I11 |
| Return Indicator | Yes |
| Depth | 4.13 inch |
| Height | 3.15 inch |
| Width | 1.77 inch |
| Weight | 0.88 pound |
| Range | TeSys |
|---|---|
| Device Short Name | LU2MB |
| Product Or Component Type | Reverser block |
| Device Mounting | Direct mounting |
| Device Application | Motor control |
| Ie Rated Operational Current | 38 A |
| [Uc] Control Circuit Voltage | 110...240 V AC 50/60 Hz 110...220 V DC |
| Current Consumption | 1000 mA 110...220 V DC I maximum while closing 1000 mA 110...240 V AC I maximum while closing |
| Ue Rated Operational Voltage | 690 V AC power circuit |
| Network Frequency | 40...60 Hz |
| Inrush Restraint Duration | 25 ms AC 15 ms DC |
| Operating Time | 150 ms with change of direction 75 ms without change of direction |
| Standards | EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier |
| Product Certifications | CE UL CSA CCC EAC ASEFA ATEX Marine |
| Ui Rated Insulation Voltage | 690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1 |
| Uimp Rated Imp Wstd Voltage | 6 kVIEC 60947-6-2 |
| Fixing Mode | Plug-in |
| Connections - Terminals | Control circuit screw clamp terminals 1 0.00…0.00 in² (0.34…1.5 mm²) 0.12 in (3 mm)) flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²) 0.12 in (3 mm)) flexible without cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²) 0.12 in (3 mm)) rigid Control circuit screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²) 0.12 in (3 mm)) flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²) 0.12 in (3 mm)) flexible without cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²) 0.12 in (3 mm)) rigid Power circuit screw clamp terminals 1 0.00…0.02 in² (1…10 mm²) 0.16 in (4 mm)) rigid Power circuit screw clamp terminals 1 0.00…0.01 in² (1…6 mm²) 0.16 in (4 mm)) flexible with cable end Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²) 0.16 in (4 mm)) flexible without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…6 mm²) 0.16 in (4 mm)) flexible with cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…6 mm²) 0.16 in (4 mm)) rigid Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²) 0.16 in (4 mm)) flexible without cable end |
| Tightening Torque | Control circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) flat 0.20 in (5 mm) Control circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) Philips No 2 0.20 in (5 mm) Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) flat 0.24 in (6 mm) Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) Philips No 2 0.24 in (6 mm) |
| Width | 1.77 in (45 mm) |
| Height | 3.15 in (80 mm) |
| Depth | 4.13 in (105 mm) |
| Product Weight | 0.88 lb(US) (0.4 kg) |
| Compatibility Code | LU2MB |
| IP Degree Of Protection | IP20 IEC 60947-1 front panel and wired terminals) IP20 IEC 60947-1 other faces) IP40 IEC 60947-1 front panel outside connection zone) |
| Protective Treatment | TH IEC 60068 |
| Ambient Air Temp For Op | -13…140 °F (-25…60 °C) with LUCM -13…158 °F (-25…70 °C) with LUCA, LUCB, LUCC, LUCD |
| Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
| Fire Resistance | 1760 °F (960 °C) parts supporting live components IEC 60695-2-12 1202 °F (650 °C) IEC 60695-2-12 |
| Operating Altitude | 6561.68 ft (2000 m) |
| Shock Resistance | 10 gn power poles open IEC 60068-2-27 15 gn power poles closed IEC 60068-2-27 |
| Vibration Resistance | 2 gn 5…300 Hz) power poles open IEC 60068-2-27 4 gn 5…300 Hz) power poles closed IEC 60068-2-27 |
| Resist Electrostatic Dischrg | 8 kV level 3, in open air IEC 61000-4-2 8 kV level 4, on contact IEC 61000-4-2 |
| Resistance To Radiated Fields | 9.14 V/m (10 V/m) level 3 IEC 61000-4-3 |
| Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
| Non-Dissipating Shock Wave | 1 kV serial mode IEC 60947-6-2 2 kV common mode IEC 60947-6-2 |
| Imm To Radioelectric Fields | 10 V IEC 61000-4-6 |
| Category | 22399 - TESYS U, ACCESSORIES |
| Discount Schedule | I11 |
| GTIN | 00785901202622 |
| Nbr. Of Units In Pkg. | 1 |
| Country Of Origin | FR |
| EU RoHs Directive | Compliant |
| Mercury Free | Yes |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Warranty | 18 months |
Powered by ![]()