| Part Number | ABLM1A12010 |
|---|---|
| UPC | 785901699200 |
| UPC11 | 78590169920 |
| EAN | 3606481500113 |
| Availability | N |
| Lead Time | 98 |
| ECCN | EAR99 |
| HTs Code | 8504409510 |
| RoHS Compliant | Yes |
| Discount Schedule | CP12 |
| Return Indicator | Yes |
| Depth | 2.19 inch |
| Height | 3.58 inch |
| Width | 0.71 inch |
| Weight | 0.22 pound |
| Range Of Product | Modicon Power Supply |
|---|---|
| Product Or Component Type | Power supply |
| Power Supply Type | Regulated switch mode |
| Variant Option | Modular |
| Enclosure Material | Plastic |
| Nominal Input Voltage | 100...240 V AC single phase 100...240 V AC 2 phases |
| Input Voltage Limits | 90...264 V AC |
| Rated Power In W | 12 W |
| Output Voltage | 12 V DC |
| Power Supply Output Current | 1 A |
| Nominal Network Frequency | 50…60 Hz |
| Network System Compatibility | TN TT IT |
| Leakage Current | 0.25 mA 240 V AC |
| Input Protection Type | Integrated fuse (not interchangeable) 3.15 A External protection (recommended) 20 A B External protection (recommended) 20 A C External protection (recommended) 2 A B External protection (recommended) 2 A C |
| Inrush Current | 15 A 115 V 30 A 230 V |
| Power Factor | 0.51 at 115 V AC 0.40 at 230 V AC |
| Efficiency | 80 % 115 V AC 80 % 230 V AC |
| Power Dissipation In W | 3 W |
| Current Consumption | < 0.4 A 115 V AC < 0.25 A 230 V AC |
| Turn-On Time | < 2 s |
| Holding Time | > 10 ms 115 V AC > 60 ms 230 V AC |
| Startup With Capacitive Loads | 3000 µF |
| Residual Ripple | < 100 mV |
| Expected Capacitor Life Time | 10 year(s) |
| Meantime Between Failure | 3000000 h at 77 °F (25 °C), full load 1000000 h at 131 °F (55 °C), 80 % load |
| Output Protection Type | Against overload and short-circuits automatic reset Against over temperature manual reset Against overvoltage manual reset |
| Connections - Terminals | Screw connection 0.5...1.5 mm², AWG 20...AWG 16) without wire end ferrule input/output Screw connection 0.5...1 mm², AWG 20...AWG 18) with wire end ferrule input/output |
| Line And Load Regulation | < 0.5 %line < 1 %load |
| Status Led | Output voltage 1 LED Green) |
| Depth | 2.19 in (55.6 mm) |
| Height | 3.58 in (91 mm) |
| Width | 0.71 in (18 mm) |
| Product Weight | 0.22 lb(US) (0.101 kg) |
| Output Coupling | Serial |
| Mounting Support | Top hat type TH35-15 rail IEC 60715 Top hat type TH35-7.5 rail IEC 60715 Double-profile DIN rail panel mounting |
| Standards | EN 62368-1 EN/IEC 61010-1 EN 61010-2-201 EN/IEC 61204-3 EN 61000-6-1 EN 61000-6-2 EN 61000-6-3 EN 61000-6-4 EN 61000-3-2 EN 61000-3-3 UL 62368-1 UL 61010-1 UL 61010-2-201 CSA C22.2 No 62368-1 CSA C22.2 No 61010-1 CSA C22.2 No 61010-2-201 |
| Product Certifications | CE CUL Listed CUL Recognized RCM CB Scheme EAC KC NEC class 2 |
| Operating Altitude | < 6561.68 ft (2000 m) overvoltage category III 2000 m...5000 m overvoltage category II |
| Shock Resistance | 100 m/s² 11 ms |
| IP Degree Of Protection | IP20 |
| Ambient Air Temp For Op | -13…131 °F (-25…55 °C) without current derating) 131…158 °F (55…70 °C) with current derating of 2.67 % per °C) |
| Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
| Relative Humidity | 0…95 % without condensation |
| Overvoltage Category | II |
| Safety Level | Cl 1 with PE connection |
| Electrical Shock Protect Class | Class II without PE connection |
| Pollution Degree | 2 |
| Vibration Resistance | 3 mm 2…9 Hz)IEC 60721-3-3 10 m/s² 9…200 Hz)IEC 60721-3-3 |
| Electromagnetic Immunity | Immunity to electrostatic discharge 6 kV contact discharge) EN/IEC 61000-4-2 Immunity to electrostatic discharge 9 kV air discharge) EN/IEC 61000-4-2 Electromagnetic field immunity test 10 V/m 80 MHz...2 GHz) EN/IEC 61000-4-3 Electromagnetic field immunity test 5 V/m 2...2.7 GHz) EN/IEC 61000-4-3 Electromagnetic field immunity test 3 V/m 2.7...6 GHz) EN/IEC 61000-4-3 Immunity to fast transients 4 kV on input-output) EN/IEC 61000-4-4 Surge immunity test 3 kV between power supply and earth) EN/IEC 61000-4-5 Surge immunity test 1.5 kV between phases) EN/IEC 61000-4-5 Immunity to conducted disturbances 10 Vrms 0.15...80 MHz) EN/IEC 61000-4-6 Immunity to magnetic fields 30 A/m 50...60 Hz) EN/IEC 61000-4-8 Immunity to voltage dips 100 % 1 cycle) EN/IEC 61000-4-11 Immunity to voltage dips 60 % 10 cycles) EN/IEC 61000-4-11 Immunity to voltage dips 30 % 25 cycles) EN/IEC 61000-4-11 Disturbing field emission EN 55016-2-3 Limits for harmonic current emissions EN 61000-3-2 Conducted disturbance emission EN 55016-1-2 Conducted disturbance emission EN 55016-2-1 |
| Electromagnetic Emission | Conducted emissions EN 61000-6-3 Radiated emissions EN 61000-6-4 |